Refine
Year of publication
- 2017 (259) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (67)
- Fachbereich Elektrotechnik und Informationstechnik (37)
- IfB - Institut für Bioengineering (34)
- Fachbereich Luft- und Raumfahrttechnik (33)
- Fachbereich Wirtschaftswissenschaften (32)
- Fachbereich Energietechnik (27)
- INB - Institut für Nano- und Biotechnologien (27)
- Fachbereich Maschinenbau und Mechatronik (23)
- Fachbereich Bauingenieurwesen (14)
- Fachbereich Chemie und Biotechnologie (12)
Document Type
- Article (108)
- Conference Proceeding (86)
- Part of a Book (33)
- Book (14)
- Other (11)
- Part of a Periodical (2)
- Report (2)
- Contribution to a Periodical (1)
- Doctoral Thesis (1)
- Patent (1)
Keywords
- Autonomous mobile robots (2)
- Gamification (2)
- Industry 4.0 (2)
- MASCOT (2)
- Multi-robot systems (2)
- Smart factory (2)
- 3D nonlinear finite element model (1)
- Acceptance tests (1)
- Ausfachungsmauerwerk (1)
- Automated Optimization (1)
- Bein (1)
- Bewertungsframework (1)
- Biomolecular logic gate (1)
- CNOT (1)
- Capacitive field-effect (1)
- Chemical images (1)
- Chemical sensor (1)
- Chimeric liver-humanized mice (1)
- Competence Developing Gam (1)
- Competence Developing Games (1)
- Cyber-physical systems (1)
- DNA (1)
- Dehydrogenase (1)
- Diaphorase (1)
- Digitale Transformation (1)
- Diversity (1)
- Diversity Management (1)
- Drug distribution (1)
- Drug metabolism (1)
- Dry-low-NOx (DLN) combustion (1)
- EIS capacitive sensor (1)
- Education (1)
- Effective modal mass (1)
- Electrolyte–insulator–semiconductor (1)
- Elektromyographie (1)
- Elektrostimulation (1)
- Enterprise architecture (1)
- Enterprise transformation (1)
- Enzymatic biosensor (1)
- Enzyme biosensor (1)
- Enzyme logic gate (1)
- Erdbeben (1)
- Extensor (1)
- Fake (1)
- Field-effect sensor (1)
- GOSSAMER-1 (1)
- Geschäftsmodelle (1)
- Gold nanoparticle (1)
- Gossamer (1)
- Hacking (1)
- High hydrogen combustion (1)
- Higher education (1)
- Hotelling’s T² test (1)
- Hydrogen combustion (1)
- Hydrogen gas turbine (1)
- INSYSME (1)
- Image Database (1)
- Image Forensics (1)
- Innovation (1)
- Innovation Management (1)
- Knockout mice (1)
- Konsumkritik (1)
- Künstlerische Intervention (1)
- LAPS (1)
- Leadership (1)
- Light-addressable potentiometric sensor (1)
- Map (eTOM) Process reference model Process design Telecommunications industry (1)
- Micromix combustion (1)
- Mixed-Methods Research (1)
- Mobile Phones (1)
- Multiphase (1)
- Natural frequency (1)
- Negative impedance convertor (1)
- O2 plasma (1)
- Optimal Topology (1)
- PHILAE (1)
- Parasitäre Strategie (1)
- Performance measurement (1)
- Piecewise Linearization (1)
- Plant efficiency (1)
- Process design (1)
- Process reference model (1)
- Quantitative research (1)
- Raumfahrt (1)
- Reference modelling (1)
- Resonance-mode measurement (1)
- RoboCup (1)
- Sequence-Search (1)
- Serious Game (1)
- Serious Games (1)
- Similarity Theory (1)
- Simultaneous determination (1)
- Small Solar System Body Lander (1)
- Small Spacecraft (1)
- Solar Power Sail (1)
- Stahlbetonrahmen (1)
- Students (1)
- Suspension bridge (1)
- TM Forum (1)
- Telecommunication (1)
- Thin shell finite elements (1)
- Toxicology (1)
- Trajectory Optimization (1)
- Transition (1)
- Unternehmensarchitekturen (1)
- Unternehmensarchitekturen Internet der Dinge (1)
- Ventilation System (1)
- Wertschöpfungskettenanalyse (1)
- XOR (1)
- Ziegelmauerwerk (1)
- annealing (1)
- asteroid sample return (1)
- change management (1)
- churches (1)
- complete block symmetry (1)
- diversity management (1)
- earthquake engineering (1)
- elastomeric bearing (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- engineering (1)
- enhanced Telecom Operations Map (eTOM) (1)
- equivalent stiffness (1)
- friction pendulum bearing (1)
- granular silo (1)
- hydroxylation (1)
- hypoplasticity (1)
- innovation management (1)
- learning theories (1)
- likelihood ratio test (1)
- liquid storage tank (1)
- macro-element (1)
- motivation theories (1)
- multiple NEA rendezvous (1)
- nonlinear transient analyses (1)
- research association (1)
- seismic isolation (1)
- simplified approach (1)
- solar sail (1)
- surface functionalization (1)
- truss (1)
- uniformly most powerful invariant test (1)
- vault (1)
Is part of the Bibliography
- no (259)
Development and Testing of a Low NOX Micromix Combustion Chamber for an Industrial Gas Turbine
(2017)
The Micromix combustion principle, based on cross-flow mixing of air and hydrogen, promises low emission applications in future gas turbines. The Micromix combustion takes place in several hundreds of miniaturized diffusion-type micro-flames. The major advantage is the inherent safety against flash-back and low NOx-emissions due to a very short residence time of reactants in the flame region. The paper gives insight into the Micromix design and scaling procedure for different energy densities and the interaction of scaling laws and key design drivers in gas turbine integration. Numerical studies, experimental testing, gas turbine integration and interface considerations are evaluated. The aerodynamic stabilization of the miniaturized flamelets and the resulting flow field, flame structure and NOx formation are analysed experimentally and numerically. The results show and confirm the successful adaption of the low NOx Micromix characteristics for a range of different nozzle sizes, energy densities and thermal power output.
Three amperometric biosensors have been developed for the detection of L-malic acid, fumaric acid, and L -aspartic acid, all based on the combination of a malate-specific dehydrogenase (MDH, EC 1.1.1.37) and diaphorase (DIA, EC 1.8.1.4). The stepwise expansion of the malate platform with the enzymes fumarate hydratase (FH, EC 4.2.1.2) and aspartate ammonia-lyase (ASPA, EC 4.3.1.1) resulted in multi-enzyme reaction cascades and, thus, augmentation of the substrate spectrum of the sensors. Electrochemical measurements were carried out in presence of the cofactor β-nicotinamide adenine dinucleotide (NAD+) and the redox mediator hexacyanoferrate (III) (HCFIII). The amperometric detection is mediated by oxidation of hexacyanoferrate (II) (HCFII) at an applied potential of + 0.3 V vs. Ag/AgCl. For each biosensor, optimum working conditions were defined by adjustment of cofactor concentrations, buffer pH, and immobilization procedure. Under these improved conditions, amperometric responses were linear up to 3.0 mM for L-malate and fumarate, respectively, with a corresponding sensitivity of 0.7 μA mM−1 (L-malate biosensor) and 0.4 μA mM−1 (fumarate biosensor). The L-aspartate detection system displayed a linear range of 1.0–10.0 mM with a sensitivity of 0.09 μA mM−1. The sensor characteristics suggest that the developed platform provides a promising method for the detection and differentiation of the three substrates.
Die Steiff Spielwarenfabrik in Giengen / Brenz : Ein unbekanntes Meisterwerk der frühen Moderne
(2017)
A light-addressable potentiometric sensor (LAPS) is a field-effect-based potentiometric sensor with an electrolyte/insulator/semiconductor (EIS) structure, which is able to monitor analyte concentrations of (bio-)chemical species in aqueous solutions in a spatially resolved way. Therefore, it is also an appropriate tool to record 2D-chemical images of concentration variations on the sensor surface. In the present work, two differential, LAPS-based measurement principles are introduced to determine the metabolic activity of Escherichia coli (E. coli) K12 and Chinese hamster ovary (CHO) cells as test microorganisms. Hereby, we focus on i) the determination of the extracellular acidification rate (ΔpH/min) after adding glucose solutions to the cell suspensions; and ii) recording the amplitude increase of the photocurrent (Iph) related to the produced acids from E. coli K12 bacteria and CHO cells on the sensor surface by 2D-chemical imaging. For this purpose, 3D-printed multi-chamber structures were developed and mounted on the planar sensor-chip surface to define four independent compartments, enabling differential measurements with varying cell concentrations. The differential concept allows eliminating unwanted drift effects and, with the four-chamber structures, measurements on the different cell concentrations were performed simultaneously, thus reducing also the overall measuring time.