Conference Proceeding
Refine
Year of publication
Document Type
- Conference Proceeding (239) (remove)
Keywords
- Biosensor (25)
- CAD (11)
- Finite-Elemente-Methode (11)
- civil engineering (11)
- Bauingenieurwesen (10)
- Einspielen <Werkstoff> (6)
- shakedown analysis (6)
- Clusterion (4)
- Limit analysis (4)
- Natural language processing (4)
- limit analysis (4)
- Air purification (3)
- Hämoglobin (3)
- Luftreiniger (3)
- Plasmacluster ion technology (3)
- Raumluft (3)
- Shakedown (3)
- Shakedown analysis (3)
- Sonde (3)
- Traglast (3)
- Bruchmechanik (2)
- Clustering (2)
- Einspielanalyse (2)
- Eisschicht (2)
- Erythrozyt (2)
- FEM (2)
- Information extraction (2)
- Kohlenstofffaser (2)
- Lipopolysaccharide (2)
- Ratcheting (2)
- Stickstoffmonoxid (2)
- Traglastanalyse (2)
- biosensor (2)
- celldrum technology (2)
- lipopolysaccharides (2)
- nitric oxide gas (2)
- ratchetting (2)
- shakedown (2)
- 3-nitrofluoranthene (1)
- Active learning (1)
- Adsorption (1)
- Agent-based simulation (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomose (1)
- Anastomosis (1)
- Autofluoreszenzverfahren (1)
- BTEX compounds (1)
- Bakterien (1)
- Bio-Sensors (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Biophoton (1)
- Biosensorik (1)
- Blitzschutz (1)
- CAD ; (1)
- CO (1)
- Chance constrained programming (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Conducing polymer (1)
- Dattel (1)
- Deep learning (1)
- Dekontamination (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- ECT (1)
- EEG (1)
- EPN (1)
- Einspiel-Analyse (1)
- Elastodynamik (1)
- Elektrodynamik (1)
- Endothelzelle (1)
- Energy market design (1)
- Evolution of damage (1)
- Exact Ilyushin yield surface (1)
- Extension fracture (1)
- Extension strain criterion (1)
- FEM-Programm (1)
- FEM-computation (1)
- Fehlerstellen (1)
- Festkörper (1)
- Fibroblast (1)
- Finite element method (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fluorescence (1)
- Force (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Grid Computing (1)
- Gunn diode (1)
- Heavy metal detection (1)
- High throughput experimentation (1)
- Hotplate (1)
- Human Factors (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hydrogen sensor (1)
- I3S 2005 (1)
- ISFET (1)
- Impedance Spectroscopy (1)
- Information Extraction (1)
- Information Integration Tools (1)
- International Symposium on Sensor Science (1)
- Iterative learning control (1)
- Knee (1)
- Knowledge Management (1)
- Körpertemperatur (1)
- LED chip (1)
- LISA (1)
- Level sensor (1)
- Lichtstreuungsbasierte Instrumente (1)
- Load modeling (1)
- MEMS (1)
- Machine learning (1)
- Main sensitivity (1)
- Market modeling (1)
- Mechanische Beanspruchung (1)
- Microreactors (1)
- Mohr–Coulomb criterion (1)
- Multi-dimensional wave propagation (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanoparticles (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Natriumhypochlorit (1)
- Natural Language Processing (1)
- Natural language understanding (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Ontologie <Wissensverarbeitung> (1)
- Ontology Engineering (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- PFM (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Phenylalanine determination (1)
- Potentiometry (1)
- Process model (1)
- Profile Extraction (1)
- Profile extraction (1)
- Proteine (1)
- Pseudomonas putida (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Query learning (1)
- Random variable (1)
- Reaction-diffusion (1)
- Relation classification (1)
- Reliability of structures (1)
- Reproducible research (1)
- Rohr (1)
- Rohrbruch (1)
- Sensitivity (1)
- Sepsis (1)
- Sleep EEG (1)
- Solid amalgam electrodes (1)
- Stahl (1)
- Stochastic programming (1)
- Supraleiter (1)
- Technische Mechanik (1)
- Text Mining (1)
- Text mining (1)
- Tin oxide (1)
- Tobacco mosaic virus (1)
- Torsion (1)
- Torsionsbelastung (1)
- Tragfähigkeit (1)
- Training (1)
- Trustworthy artificial intelligence (1)
- UML (1)
- Unified Modeling Language (1)
- Wafer (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Workflow (1)
- Workflow Orchestration (1)
- Zug-Druck-Beanspruchung (1)
- Zug-Druck-Belastung (1)
- acetoin (1)
- activated nanostructured carbon (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- ammonia gas sensors (1)
- amperometric sensor (1)
- antimony doped tin oxide (1)
- autofluorescence-based detection system (1)
- biopotential electrodes (1)
- burst pressure (1)
- burst tests (1)
- capacitive field-effect biosensor (1)
- capillary micro-droplet cell (1)
- carcinogens (1)
- catalytic decomposition (1)
- chemical reduction method (1)
- contractile tension (1)
- cross sensitivity (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- design-by-analysis (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- enzymatic methods (1)
- enzyme immobilisation (1)
- enzyme immobilization (1)
- fenitrothion (1)
- finite element analysis (1)
- flaw (1)
- fluidic (1)
- gas sensor (1)
- gas sensor array (1)
- heater metallisation (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- high-temperature stability (1)
- humidity (1)
- hydrogel (1)
- hydrogen peroxide (1)
- image sensor (1)
- imaging (1)
- impedance spectroscopy (1)
- ion-selective electrodes (1)
- kontraktile Spannung (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- layer expansion (1)
- lenslet array (1)
- light scattering analysis (1)
- lightning flash (1)
- limit and shakedown analysis (1)
- limit load (1)
- linear kinematic hardening (1)
- load carrying capacity (1)
- load limit (1)
- lower bound theorem (1)
- magnetic particles (1)
- material shakedown (1)
- matrix method (1)
- mechanical waves (1)
- metal oxide (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-interface measurement (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- nitrogen oxides (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- organic PVC membranes (1)
- pH-based biosensing (1)
- pattern-size reduction (1)
- pipes (1)
- plant scanner (1)
- plasma generated ions (1)
- plastic deformation (1)
- polymer composites (1)
- porous Pt electrode (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- protein (1)
- quantum charging (1)
- reliability (1)
- rhAPC (1)
- screen-printing (1)
- second-order reliability method (1)
- self-aligned patterning (1)
- sensing properties (1)
- sensors (1)
- sterilisation (1)
- subsurface ice research (1)
- subsurface probe (1)
- surface modification (1)
- swift heavy ions (1)
- tension–torsion loading (1)
- thick-film technology (1)
- thin-film microsensors (1)
- vessels (1)
- voltammetry (1)
- wafer-level testing (1)
- water bridge phenomenon (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (239) (remove)
Traglast- und Einspielanalysen sind vereinfachte doch exakte Verfahren der klassischen Plastizitätstheorie, die neben ausreichender Verformbarkeit keine einschränkenden Voraussetzungen beinhalten. Die Vereinfachungen betreffen die Beschaffung der Daten und Modelle für Details der Lastgeschichte und des Stoffverhaltens. Eine FEM-basierte Traglast- und Einspielanalyse für ideal plastisches Material wurde auf ein kinematisch verfestigendes Materialgesetz erweitert und in das Finite Element Programm PERMAS implementiert. In einem einfachen Zug-Torsionsexperiment wurde eine Hohlprobe mit konstanter Torsion und zyklischer Zugbelastung beansprucht, um die neue Implementierung zu verifizieren. Es konnte gezeigt werden, dass die Einspielanalyse gut mit den experimentellen Ergebnissen übereinstimmt. Bei Verfestigung lassen sich wesentlich größere Sicherheiten nachweisen. Dieses Potential bedarf weiterer experimenteller Absicherung. Parallel dazu ist die Eisnpieltheorie auf fortschrittliche Verfestigungsansätze zu erweitern.
Summary and Conclusions PCIs were clearly effective in terms of their antibacterial effects with the strains tested. This efficacy increased with the time the bacteries were exposed to PCIs. The bactericidal action has proved to be irreversible. PCIs were significantly less effective in shadowed areas. PCI exposure caused multiple protein damages as observed in SDS PAGE studies. There was no single but multiple molecular mechanism causing the bacterial death.
Effectiveness of the edge-based smoothed finite element method applied to soft biological tissues
(2012)
As a deduction from these results, we can conclude that proteins mainly in vitro, denaturate totally at a temperature between 57°C -62°C, and they also affected by NO and different ions types. In which mainly, NO cause earlier protein denaturation, which means that, NO has a destabilizing effect on proteins, and also different ions will alter the protein denaturation in which, some ions will cause earlier protein denaturation while others not.
Pulmonary arterial cannulation is a common and effective method for percutaneous mechanical circulatory support for concurrent right heart and respiratory failure [1]. However, limited data exists to what effect the positioning of the cannula has on the oxygen perfusion throughout the pulmonary artery (PA). This study aims to evaluate, using computational fluid dynamics (CFD), the effect of different cannula positions in the PA with respect to the oxygenation of the different branching vessels in order for an optimal cannula position to be determined. The four chosen different positions (see Fig. 1) of the cannulas are, in the lower part of the main pulmonary artery (MPA), in the MPA at the junction between the right pulmonary artery (RPA) and the left pulmonary artery (LPA), in the RPA at the first branch of the RPA and in the LPA at the first branch of the LPA.
Conventional EEG devices cannot be used in everyday life and
hence, past decade research has been focused on Ear-EEG for mobile,
at-home monitoring for various applications ranging from
emotion detection to sleep monitoring. As the area available for
electrode contact in the ear is limited, the electrode size and location
play a vital role for an Ear-EEG system. In this investigation, we
present a quantitative study of ear-electrodes with two electrode
sizes at different locations in a wet and dry configuration. Electrode
impedance scales inversely with size and ranges from 450 kΩ to
1.29 MΩ for dry and from 22 kΩ to 42 kΩ for wet contact at 10 Hz.
For any size, the location in the ear canal with the lowest impedance
is ELE (Left Ear Superior), presumably due to increased contact
pressure caused by the outer-ear anatomy. The results can be used
to optimize signal pickup and SNR for specific applications. We
demonstrate this by recording sleep spindles during sleep onset
with high quality (5.27 μVrms).