Refine
Year of publication
- 2011 (329) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (82)
- Fachbereich Elektrotechnik und Informationstechnik (40)
- INB - Institut für Nano- und Biotechnologien (37)
- Fachbereich Wirtschaftswissenschaften (34)
- IfB - Institut für Bioengineering (34)
- Fachbereich Energietechnik (29)
- Fachbereich Chemie und Biotechnologie (28)
- Fachbereich Bauingenieurwesen (24)
- Fachbereich Maschinenbau und Mechatronik (24)
- Fachbereich Luft- und Raumfahrttechnik (23)
Document Type
- Article (182)
- Conference Proceeding (76)
- Book (24)
- Part of a Book (22)
- Report (7)
- Patent (5)
- Conference: Meeting Abstract (3)
- Other (3)
- Doctoral Thesis (2)
- Part of a Periodical (2)
Keywords
- Aachen / Fachhochschule Aachen (3)
- Aachen University of Applied Sciences (3)
- Aktionskunst (3)
- FH Aachen (2)
- Illustration (2)
- Interaktive Kunst (2)
- Kommunikationsguerrilla (2)
- Pflanzenphysiologie (2)
- Pflanzenscanner (2)
- Stadtgestaltung (2)
- Streetart (2)
- plant scanner (2)
- Öffentlicher Raum (2)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (1)
- Absolvententreffen (1)
- Alfha.net (1)
- Alumni (1)
- Anastomose (1)
- Anastomosis (1)
- Angewandte Forschung (1)
- Arthosetherapie (1)
- Benutzerumfrage (1)
- Biomechanics (1)
- Biomechanik (1)
- Bioreaktor (1)
- Blutzellenlagerung (1)
- Book Project (1)
- Business Process (1)
- Customer Orientation (1)
- Dattel (1)
- Design (1)
- Diagramm (1)
- Editorial (1)
- Eisschicht (1)
- Enterprise Architecture (1)
- Fachhochschule Aachen (1)
- Finite element method (1)
- Finite-Elemente-Methode (1)
- Forschungsbericht (1)
- Gebrauchsgrafik (1)
- Gonarthrose (1)
- Graduiertentagung (1)
- Grafikdesign (1)
- Graphic Design (1)
- Harnleiter (1)
- Hemoglobin structure (1)
- High field MRI (1)
- Hämoglobin (1)
- Hämoglobinstruktur (1)
- Infografik (1)
- Information Design (1)
- Kindermöbel (1)
- Kinetische Kunst (1)
- Kleinkind (1)
- Kniegelenkarthrose (1)
- Lichtkunst (1)
- MBST (1)
- MR safety (1)
- MRI (1)
- Mack, Heinz (1)
- Magneto alert sensor (1)
- McLuhan, Marshall (1)
- Mediendesign (1)
- Meinungsäußerung (1)
- Modulsystem (1)
- Multifunktionsmöbel (1)
- Netzkunst (1)
- Organkultur (1)
- Papierkunst (1)
- Pflanzenstress (1)
- Pornographie (1)
- Produktdesign (1)
- Raumerfahrung (1)
- Red blood cell storage (1)
- Research Report (1)
- Sammelobjekt (1)
- Schwarzweißphotographie (1)
- Sitzmöbel (1)
- Sonde (1)
- Spielmöbel (1)
- Spielzeug (1)
- Strickmuster (1)
- Telecommunication Industry (1)
- Tissue Engineering (1)
- Transformation Project (1)
- Tribute (1)
- Uktrahigh field MRI (1)
- User Survey (1)
- Wissens- und Technologietransfer (1)
- Zuschauer (1)
- arthrosis therapy (1)
- avalanche (1)
- date palm tree (1)
- gonarthrosis (1)
- heliosphere (1)
- ion propulsion (1)
- low-thrust trajectory optimization (1)
- plant stress (1)
- snow (1)
- subsurface ice research (1)
- subsurface probe (1)
Air-sand heat exchanger
(2011)
Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus
(2011)
Absatzkanäle kaum verknüpft
(2011)
Objective:
To develop a transmit/receive radiofrequency (RF) array for magnetic resonance imaging (MRI) of the carotid arteries at 7 T. The prototype is characterized in numerical simulations and bench measurements, and the feasibility of plaque imaging at 7 T is demonstrated in first in vivo images.
Materials and Methods:
The RF phased array coil consists of 8 surface loop coils. To allow imaging of both sides of the neck, the RF array is divided into 2 coil clusters, each with 4 overlapping loop elements. For safety validation, numerical computations of the RF field distribution and the corresponding specific absorption rate were performed on the basis of a heterogeneous human body model. To validate the coil model, maps of the transmit B1+ field were compared between simulation and measurement. In vivo images of a healthy volunteer and a patient (ulcerating plaque and a 50% stenosis of the right internal carotid artery) were acquired using a 3-dimensional FLASH sequence with a high isotropic spatial resolution of 0.54 mm as well as using pulse-triggered proton density (PD)/T2-weighted turbo spin echo sequences.
Results:
Measurements of the S-parameters yielded a reflection and isolation of the coil elements of better than −18 and −13 dB, respectively. Measurements of the g-factor indicated good image quality for parallel imaging acceleration factors up to 2.4. A similar distribution and a very good match of the absolute values were found between the measured and simulated B1+ transmit RF field for the validation of the coil model. In vivo images revealed good signal excitation of both sides of the neck and a high vessel-to-background image contrast for the noncontrast-enhanced 3-dimensional FLASH sequence. Imaging at 7 T could depict the extent of stenosis, and revealed the disruption and ulcer of the plaque.
Conclusions:
This study demonstrates that 2 four-channel transmit/receive RF arrays for each side of the neck is a suitable concept for in vivo MRI of the carotid arteries at 7 Tesla. Further studies are needed to explore and exploit the full potential of 7 T high-field MRI for carotid atherosclerotic plaque imaging.