Refine
Year of publication
Document Type
- Article (479)
- Conference Proceeding (45)
- Part of a Book (9)
- Book (2)
- Other (2)
Language
- English (537) (remove)
Keywords
- Biosensor (7)
- LAPS (4)
- hydrogen peroxide (4)
- Field-effect sensor (3)
- Label-free detection (3)
- Light-addressable potentiometric sensor (3)
- biosensors (3)
- Bacillus atrophaeus (2)
- Capacitive field-effect sensor (2)
- Raman spectroscopy (2)
- Tobacco mosaic virus (TMV) (2)
- acetoin (2)
- capacitive field-effect sensors (2)
- field-effect sensor (2)
- sterilisation (2)
- tobacco mosaic virus (TMV) (2)
- (Bio)degradation (1)
- Bacillus atrophaeus spores (1)
- Bio-Sensors (1)
- Bioabsorbable (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (537) (remove)
In vitro studies of the degradation kinetic of biopolymers are essential for the design and optimization of implantable biomedical devices. In the presented work, a field-effect capacitive sensor has been applied for the real-time and in situ monitoring of degradation processes of biopolymers for the first time. The polymer-covered field-effect sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. The feasibility of this approach has been experimentally proven by using the commercially available biomedical polymer poly(D,L-lactic acid) (PDLLA) as a model system. PDLLA films of different thicknesses were deposited on the Ta₂O₅-gate surface of the field-effect structure from a polymer solution by means of spin-coating method. The polymer-modified field-effect sensors have been characterized by means of capacitance–voltage and impedance-spectroscopy method. The degradation of the PDLLA was accelerated by changing the degradation medium from neutral (pH 7.2) to alkaline (pH 9) condition, resulting in drastic changes in the capacitance and impedance spectra of the polymer-modified field-effect sensor.
Characterising an insect antenna as a receptor for a biosensor by means of impedance spectroscopy
(2001)
Characterisation of polymeric materials as passivation layer for calorimetric H2O2 gas sensors
(2012)
Calorimetric gas sensors for monitoring the H₂O₂ concentration at elevated temperatures in industrial sterilisation processes have been presented in previous works. These sensors are built up in form of a differential set-up of a catalytically active and passive temperature-sensitive structure. Although, various types of catalytically active dispersions have been studied, the passivation layer has to be established and therefore, chemically as well as physically characterised. In the present work, fluorinated ethylene propylene (FEP), perfluoralkoxy (PFA) and epoxy-based SU-8 photoresist as temperature-stable polymeric materials have been investigated for sensor passivation in terms of their chemical inertness against H₂O₂, their hygroscopic properties as well as their morphology. The polymeric materials were deposited via spin-coating on the temperature-sensitive structure, wherein spin-coated FEP and PFA show slight agglomerates. However, they possess a low absorption of humidity due to their hydrophobic surface, whereas the SU-8 layer has a closed surface but shows a slightly higher absorption of water. All of them were inert against gaseous H₂O₂ during the characterisation in H₂O₂ atmosphere that demonstrates their suitability as passivation layer for calorimetric H₂O₂ gas sensors.