Refine
Year of publication
Document Type
- Article (542)
- Conference Proceeding (63)
- Part of a Book (11)
- Book (2)
- Other (2)
- Report (2)
- Patent (1)
Language
- English (551)
- German (71)
- Multiple languages (1)
Keywords
- Biosensor (7)
- Graduiertentagung (5)
- LAPS (4)
- field-effect sensor (4)
- hydrogen peroxide (4)
- Field-effect sensor (3)
- Label-free detection (3)
- Light-addressable potentiometric sensor (3)
- biosensors (3)
- capacitive field-effect sensor (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Calorimetric gas sensor (2)
- Capacitive field-effect sensor (2)
- Graduate symposium (2)
- Hydrogen peroxide (2)
- Raman spectroscopy (2)
- Tobacco mosaic virus (TMV) (2)
- acetoin (2)
- capacitive field-effect sensors (2)
- gold nanoparticles (2)
- light-addressable potentiometric sensor (2)
- penicillinase (2)
- sterilisation (2)
- (Bio)degradation (1)
- Aachen / Fachhochschule Aachen (1)
- Aachen / Fachhochschule Aachen ; Graduierter ; Promotionsstudium (1)
- Bacillus atrophaeus spores (1)
- Bio-Sensors (1)
- Bioabsorbable (1)
- Biomolecular logic gate (1)
- Biophoton (1)
- Biosensorik (1)
- CNOT (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Chemical images (1)
- Chemical imaging (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Coat protein (1)
- C–V method (1)
- DNA (1)
- DNA biosensor (1)
- DNA hybridization (1)
- DPA (dipicolinic acid) (1)
- Dehydrogenase (1)
- Diaphorase (1)
- EIS capacitive sensor (1)
- Electrolyte–insulator–semiconductor (1)
- Enzymatic biosensor (1)
- Enzyme biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme nanocarrier (1)
- Field effect (1)
- Field-effect biosensor (1)
- Field-effect device (1)
- Gas sensor (1)
- Glucose biosensor (1)
- Glucose oxidase (1)
- Gold nanoparticle (1)
- Gold nanoparticles (1)
- Graduierter (1)
- Heavy metal detection (1)
- I3S 2005 (1)
- ISFET (1)
- Impedance spectroscopy (1)
- International Symposium on Sensor Science (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- Light-addressable Potentiometric Sensor (1)
- MEMS (1)
- MOS (1)
- Multi-sensor system (1)
- Multianalyte detection (1)
- Multicell (1)
- Multiplexing (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Negative impedance convertor (1)
- O2 plasma (1)
- Organic light-emitting diode display (1)
- Penicillin (1)
- Plant virus (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polylactide acid (1)
- Potentiometry (1)
- Promotionsstudium (1)
- Real-time monitoring (1)
- Resistive temperature detector (1)
- Resonance-mode measurement (1)
- Silk fibroin (1)
- Simultaneous determination (1)
- Sn₃O₄ (1)
- Sterilisation process (1)
- Supraleiter (1)
- TMV adsorption (1)
- Ta₂O₅ gate (1)
- Tobacco mosaic virus (1)
- Wafer (1)
- XOR (1)
- Zeta potential (1)
- acetoin reductase (1)
- actuator-sensor system (1)
- alcoholic beverages (1)
- aminooctanethiol (1)
- amperometric biosensors (1)
- annealing (1)
- artificial olfactory image (1)
- aseptic parameters (1)
- atomic layer deposition (1)
- barium strontium titanate (1)
- bi-enzyme biosensor (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- biosensor (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive EIS sensor (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capacitive field-effect biosensor (1)
- capacitive model (1)
- capillary micro-droplet cell (1)
- carbon electrodes (1)
- catalytic decomposition (1)
- catalytic metal (1)
- chemical sensor (1)
- contactless conductivity sensor (1)
- control gate (1)
- detection of charged macromolecules (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electrolyte-insulator-semiconductor capacitors (1)
- electronic nose (1)
- encapsulation materials (1)
- endospores (1)
- enzymatic (bio)degradation (1)
- enzymatic biosensor (1)
- enzyme cascade (1)
- enzyme immobilization (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- equivalent circuit (1)
- fibroin (1)
- field-effect structure (1)
- gas sensor (1)
- gaseous hydrogen peroxide (1)
- glucose (1)
- glucose oxidase (GOx) (1)
- graphene oxide (1)
- heavy metals (1)
- high-k material (1)
- horseradish peroxidase (HRP) (1)
- hydroxylation (1)
- immobilization (1)
- impedance spectroscopy (1)
- in-situ monitoring (1)
- lable-free detection (1)
- layer expansion (1)
- layer-by-layer technique (1)
- light-addressable electrode (1)
- light-addressing technologies (1)
- metal-oxide-semiconductor structure (1)
- microfluidics (1)
- multi-functional material (1)
- multi-sensing platform (1)
- multianalyte detection (1)
- nanobelts (1)
- nanomaterials (1)
- nanoparticle coverage (1)
- novel photoexcitation method (1)
- on-chip integrated addressable EISCAP sensors (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organic PVC membranes (1)
- organosilanes (1)
- pH sensors (1)
- pattern-size reduction (1)
- penicillin (1)
- photoelectrochemistry (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- poly(d, l-lactic acid) (1)
- polyaniline (1)
- polystyrene sulfonate (1)
- scanned light pulse technique (1)
- self-aligned patterning (1)
- silanization (1)
- spatial resolution (1)
- spore kill rate (1)
- sterility (1)
- sterility tests (1)
- sterilization (1)
- sterilization conditions (1)
- sterilization efficacy (1)
- sterilization methods (1)
- surface functionalization (1)
- temperature (1)
- thin-film microsensors (1)
- tilted constant illumination (1)
- titanium dioxide photoanode (1)
- turnip vein clearing virus (TVCV) (1)
- ultrathin gate insulators (1)
- urease (1)
- validation methods (1)
- visualization (1)
- wafer-level testing (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (603)
- INB - Institut für Nano- und Biotechnologien (526)
- Fachbereich Chemie und Biotechnologie (40)
- FH Aachen (5)
- Nowum-Energy (5)
- Fachbereich Energietechnik (4)
- Institut fuer Angewandte Polymerchemie (3)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- Fachbereich Elektrotechnik und Informationstechnik (1)
High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed.
Multi-parameter detection for supporting monitoring and control of biogas processes in agriculture
(2014)
In the present work, a novel method for monitoring sterilisation processes with gaseous H2O2 in combination with heat activation by means of a specially designed calorimetric gas sensor was evaluated. Therefore, the sterilisation process was extensively studied by using test specimens inoculated with Bacillus atrophaeus spores in order to identify the most influencing process factors on its microbicidal effectiveness. Besides the contact time of the test specimens with gaseous H2O2 varied between 0.2 and 0.5 s, the present H2O2 concentration in a range from 0 to 8% v/v (volume percent) had a strong influence on the microbicidal effectiveness, whereas the change of the vaporiser temperature, gas flow and humidity were almost negligible. Furthermore, a calorimetric H2O2 gas sensor was characterised in the sterilisation process with gaseous H2O2 in a wide range of parameter settings, wherein the measurement signal has shown a linear response against the H2O2 concentration with a sensitivity of 4.75 °C/(% v/v). In a final step, a correlation model by matching the measurement signal of the gas sensor with the microbial inactivation kinetics was established that demonstrates its suitability as an efficient method for validating the microbicidal effectiveness of sterilisation processes with gaseous H2O2.
Designing novel or optimizing existing biodegradable polymers for biomedical applications requires numerous tests on the effect of substances on the degradation process. In the present work, polymer-modified electrolyte–insulator–semiconductor (PMEIS) sensors have been applied for monitoring an enzymatically catalyzed degradation of polymers for the first time. The thin films of biodegradable polymer poly(d,l-lactic acid) and enzyme lipase were used as a model system. During degradation, the sensors were read-out by means of impedance spectroscopy. In order to interpret the data obtained from impedance measurements, an electrical equivalent circuit model was developed. In addition, morphological investigations of the polymer surface have been performed by means of in situ atomic force microscopy. The sensor signal change, which reflects the progress of degradation, indicates an accelerated degradation in the presence of the enzyme compared to hydrolysis in neutral pH buffer media. The degradation rate increases with increasing enzyme concentration. The obtained results demonstrate the potential of PMEIS sensors as a very promising tool for in situ and real-time monitoring of degradation of polymers.
Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security.