Refine
Year of publication
- 2020 (245) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (59)
- Fachbereich Energietechnik (35)
- Fachbereich Wirtschaftswissenschaften (35)
- Fachbereich Luft- und Raumfahrttechnik (33)
- IfB - Institut für Bioengineering (33)
- Fachbereich Elektrotechnik und Informationstechnik (29)
- ECSM European Center for Sustainable Mobility (19)
- Fachbereich Maschinenbau und Mechatronik (18)
- Fachbereich Bauingenieurwesen (14)
- Solar-Institut Jülich (14)
Language
- English (172)
- German (71)
- Multiple languages (1)
- Dutch (1)
Document Type
- Article (135)
- Conference Proceeding (55)
- Part of a Book (20)
- Book (9)
- Review (7)
- Other (4)
- Doctoral Thesis (3)
- Patent (3)
- Administrative publication (3)
- Conference Poster (2)
Keywords
- Amtliche Mitteilung (3)
- MINLP (3)
- Additive manufacturing (2)
- Adjacent buildings (2)
- Experimental validation (2)
- Historical centres (2)
- INODIS (2)
- SIJ (2)
- Shake table test (2)
- Solar-Institut Jülich (2)
- Stone masonry (2)
- Verwaltungs- und Benutzungsordnung (2)
- rebound-effect (2)
- sustainability (2)
- 3D printing (1)
- Acceptance (1)
- Adaptive control (1)
- Anwendungsorientierter Forschungsansatz (1)
- Atmospheres (1)
- Aufhebungsordnung (1)
- Biofuel (1)
- Biorefinery (1)
- Blind prediction competition (1)
- Brownian Pillow (1)
- Bumblebees (1)
- Butanol (1)
- Capacity Building Higher Education (1)
- Capacity Curve (1)
- Case study (1)
- Change culture (1)
- Choleratoxin B (1)
- Clostridium acetobutylicum (1)
- Conservation laws (1)
- Cooling system (1)
- Crámer–von-Mises distance (1)
- Datenschutz (1)
- Design Science Research (1)
- Deutschland (1)
- Digital manufacturing (1)
- Digitalization (1)
- Dimensional splitting (1)
- E-Learning (1)
- Efficiency optimization (1)
- Energiewirtschaft & Informatik (1)
- Engineering optimisation (1)
- Engineering optimization (1)
- Enhanced Telecom Operations Map (1)
- Entropy solution (1)
- Ethics (1)
- European Framework and South East Asia (1)
- Exoplanet (1)
- Exponential time differencing (1)
- Finite difference methods (1)
- Flight control (1)
- Glass powder (1)
- Higher-order codes (1)
- Hoeffding-Blum-Kiefer-Rosenblatt independence test (1)
- Human Development Index (1)
- Human factors (1)
- Human-robot collaboration (1)
- Implicit methods (1)
- Incomplete data (1)
- Industrial optimisation (1)
- Interactive process mining (1)
- Interior transmission eigenvalues (1)
- Iterative learning control (1)
- Kirchenrecht (1)
- L-PBF (1)
- Laser processing (1)
- Lean thinking (1)
- Lignocellulose (1)
- Literaturanalyse (1)
- Literaturrecherche (1)
- MAV (1)
- MILP (1)
- Malaysian Automotive Industry (1)
- Marginal homogeneity test (1)
- Masonry structures (1)
- Master (1)
- Matrix exponential (1)
- Melting (1)
- Methodology (1)
- Mixed-integer programming (1)
- Monotone methods (1)
- Multi-dimensional partial differential equations (1)
- Neo-Deterministic (1)
- Network design (1)
- Nonlinear PDEs (1)
- OR 2019 (1)
- Objective data (1)
- Obstacle avoidance (1)
- Paired sample (1)
- Payload (1)
- Piecewise linearization (1)
- Powertrain (1)
- Praxisprojekte (1)
- Process engineering (1)
- Prozessautomatisierung (1)
- Prozessverbesserung (1)
- Prüfungsordnung (1)
- Pumping systems (1)
- RPA (1)
- Rapid manufacturing (1)
- Rapid prototyping (1)
- Reaction-diffusion systems (1)
- Real distinct pole (1)
- Referenzmodellierung (1)
- Resampling test (1)
- Resilience assessment (1)
- Resilience metric graph theory (1)
- Resilient infrastructure (1)
- Robotic Process Automation (1)
- Robotic rehabilitation (1)
- SSE) JEL : O33 (1)
- Seismic Hazard (1)
- Selektionskriterien (1)
- Source term (1)
- Spectroscopy (1)
- Technical Operations Research (1)
- Technology Transfer (1)
- Text Analytics (1)
- Text Mining (1)
- Transit (1)
- Trinkwassersicherheit (1)
- UAV (1)
- Vulnerability Curves (1)
- Water distribution system (1)
- Water supply system (1)
- agility (1)
- anticipation strategy (1)
- architectural design (1)
- architectural layered representation (1)
- automotive (1)
- berichtigt (1)
- business analytics (1)
- cholera toxin B (1)
- community dwelling (1)
- connection detail (1)
- corporate sustainability (1)
- critical (1)
- decision analytics (1)
- digital economy (1)
- digital twin (1)
- drinking water safety (1)
- earthquake (1)
- efficiency side-effects (1)
- elastic scattering (1)
- fault detection (1)
- grey energy (1)
- healthy aging (1)
- in-plane (1)
- in-plane behaviour (1)
- industry 4.0 (1)
- jevons paradox (1)
- literature (1)
- magnetic frequency mixing technique (1)
- marketing (1)
- masonry infill (1)
- mathematical optimization (1)
- method of fundamental solutions (1)
- not identically distributed (1)
- out-of-plane (1)
- out-of-plane behaviour (1)
- performativity in personal knowledge (1)
- personal way of designing (1)
- prevention (1)
- psychosocial (1)
- random effects meta-regression model (1)
- resource abundance (1)
- review (1)
- seismic (1)
- socio-economic welfare (1)
- systematic (1)
- water supply system (1)
Is part of the Bibliography
- no (245)
Purpose
The aim of this study was to compare several osteosynthesis techniques (intramedullary headless compression screws, T-plates, and Kirschner wires) for distal epiphyseal fractures of proximal phalanges in a human cadaveric model.
Methods
A total of 90 proximal phalanges from 30 specimens (index, ring, and middle fingers) were used for this study. After stripping off all soft tissue, a transverse distal epiphyseal fracture was simulated at the proximal phalanx. The 30 specimens were randomly assigned to 1 fixation technique (30 per technique), either a 3.0-mm intramedullary headless compression screw, locking plate fixation with a 2.0-mm T-plate, or 2 oblique 1.0-mm Kirschner wires. Displacement analysis (bending, distraction, and torsion) was performed using optical tracking of an applied random speckle pattern after osteosynthesis. Biomechanical testing was performed with increasing cyclic loading and with cyclic load to failure using a biaxial torsion-tension testing machine.
Results
Cannulated intramedullary compression screws showed significantly less displacement at the fracture site in torsional testing. Furthermore, screws were significantly more stable in bending testing. Kirschner wires were significantly less stable than plating or screw fixation in any cyclic load to failure test setup.
Conclusions
Intramedullary compression screws are a highly stable alternative in the treatment of transverse distal epiphyseal phalangeal fractures. Kirschner wires seem to be inferior regarding displacement properties and primary stability.
Clinical relevance
Fracture fixation of phalangeal fractures using plate osteosynthesis may have the advantage of a very rigid reduction, but disadvantages such as stiffness owing to the more invasive surgical approach and soft tissue irritation should be taken into account. Headless compression screws represent a minimally invasive choice for fixation with good biomechanical properties.
Die NATO definiert den Cyberspace als die "Umgebung, die durch physische und nicht-physische Bestandteile zum Speichern, Ändern, und Austauschen von Daten mit Hilfe von Computer-Netzwerken" [NATO CCDCOE]. Darüber hinaus ist es ein Medium menschlicher Interaktion. IT Angriffe sind feindselige, nichtkooperative Interaktionen, die mittels Konflikttheorie beschrieben werden können. Durch die Anwendung dieses Gedankengebäudes auf IT Sicherheit von Organisationen können eine Reihe von Verbesserungen in Unternehmen identifiziert werden.
Successful optimization requires an appropriate model of the system under consideration. When selecting a suitable level of detail, one has to consider solution quality as well as the computational and implementation effort. In this paper, we present a MINLP for a pumping system for the drinking water supply of high-rise buildings. We investigate the influence of the granularity of the underlying physical models on the solution quality. Therefore, we model the system with a varying level of detail regarding the friction losses, and conduct an experimental validation of our model on a modular test rig. Furthermore, we investigate the computational effort and show that it can be reduced by the integration of domain-specific knowledge.
The application of mathematical optimization methods for water supply system design and operation provides the capacity to increase the energy efficiency and to lower the investment costs considerably. We present a system approach for the optimal design and operation of pumping systems in real-world high-rise buildings that is based on the usage of mixed-integer nonlinear and mixed-integer linear modeling approaches. In addition, we consider different booster station topologies, i.e. parallel and series-parallel central booster stations as well as decentral booster stations. To confirm the validity of the underlying optimization models with real-world system behavior, we additionally present validation results based on experiments conducted on a modularly constructed pumping test rig. Within the models we consider layout and control decisions for different load scenarios, leading to a Deterministic Equivalent of a two-stage stochastic optimization program. We use a piecewise linearization as well as a piecewise relaxation of the pumps’ characteristics to derive mixed-integer linear models. Besides the solution with off-the-shelf solvers, we present a problem specific exact solving algorithm to improve the computation time. Focusing on the efficient exploration of the solution space, we divide the problem into smaller subproblems, which partly can be cut off in the solution process. Furthermore, we discuss the performance and applicability of the solution approaches for real buildings and analyze the technical aspects of the solutions from an engineer’s point of view, keeping in mind the economically important trade-off between investment and operation costs.
As part of the transnational research project EDITOR, a parabolic trough collector system (PTC) with concrete thermal energy storage (C-TES) was installed and commissioned in Limassol, Cyprus. The system is located on the premises of the beverage manufacturer KEAN Soft Drinks Ltd. and its function is to supply process steam for the factory's pasteurisation process [1]. Depending on the factory's seasonally varying capacity for beverage production, the solar system delivers between 5 and 25 % of the total steam demand. In combination with the C-TES, the solar plant can supply process steam on demand before sunrise or after sunset. Furthermore, the C-TES compensates the PTC during the day in fluctuating weather conditions. The parabolic trough collector as well as the control and oil handling unit is designed and manufactured by Protarget AG, Germany. The C-TES is designed and produced by CADE Soluciones de Ingeniería, S.L., Spain. In the focus of this paper is the description of the operational experience with the PTC, C-TES and boiler during the commissioning and operation phase. Additionally, innovative optimisation measures are presented.
We present first results from a newly developed monitoring station for a closed loop geothermal heat pump test installation at our campus, consisting of helix coils and plate heat exchangers, as well as an ice-store system. There are more than 40 temperature sensors and several soil moisture content sensors distributed around the system, allowing a detailed monitoring under different operating conditions.In the view of the modern development of renewable energies along with the newly concepts known as Internet of Things and Industry 4.0 (high-tech strategy from the German government), we created a user-friendly web application, which will connect the things (sensors) with the open network (www). Besides other advantages, this allows a continuous remote monitoring of the data from the numerous sensors at an arbitrary sampling rate.Based on the recorded data, we will also present first results from numerical simulations, taking into account all relevant heat transport processes.The aim is to improve the understanding of these processes and their influence on the thermal behavior of shallow geothermal systems in the unsaturated zone. This will in turn facilitate the prediction of the performance of these systems and therefore yield an improvement in their dimensioning when designing a specific shallow geothermal installation.
Die Versorgung von Neubauten soll möglichst weitgehend unabhängig von fossilen Energieträgern erfolgen. Erneuerbare Energien spielen dafür eine gewichtige Rolle. Eine gute Möglichkeit, erneuerbare Energien ohne viel zusätzlichen Aufwand nutzbar zu machen, ist, bereits vorhandenen Komponenten im Gebäude zusätzliche Funktionen zu geben. Hier kann bspw. die Fassade oder das Dach solarthermisch aktiviert oder durch Fotovoltaikmodule ergänzt werden. Auch Tiefgründungen können neben der statischen Funktion noch eine geothermische Funktion zur Aufnahme oder Abgabe von Wärme erhalten. Neben der Erzeugung bietet sich auch für die Verteilung der Wärme oder Kälte im Gebäude die Integration in Bauteile an. Hier kann bspw. der Boden durch eine Fußbodenheizung oder die Decke durch Deckenstrahlplatten aktiviert werden.
Im Rahmen der Veröffentlichung wird auf die thermische Aktivierung von Stahlkomponenten eingegangen. Es wird eine Lösung vorgestellt, die vorgehängte hinterlüftete Stahlfassade (VHF) solarthermisch zu aktivieren. Außerdem werden zwei Möglichkeiten zur geothermischen Aktivierung von Tiefgründungen mittels Stahlpfählen gezeigt. Zuletzt wird ein System zur thermischen Aktivierung von Stahltrapezprofilen an der Decke erläutert, welches Wärme zuführen oder bei Bedarf abführen kann.
Armiranobetonske (AB) zgrade sa zidanom ispunom
se izvode u mnogim zemljama širom sveta. Iako se
zidana ispuna posmatra kao nekonstruktivni element, ona
značajno utiče na promenu dinamičkih karakteristika AB
ramovskih konstrukcija u toku zemljotresnog dejstva.
Odskora, značajan napor je utrošen na istraživanje
izolovanih ispuna, koje su odvojene od okolnog rama
obično ostavljanjem prostora između rama i ispune. U
ovom slučaju deformacija rama ne aktivira ispunu i na taj
način ispuna ne utiče na ponašanje rama. Ovaj rad
predstavlja rezultate istraživanja ponašanja AB
ramovskih zgrada sa INODIS sistemom koji izoluje ispunu
u odnosu na okolni ram. Uticaj izolovane ispune je prvo
ispitan na jednospratnim i jednobrodnim ramovima. Ovo
je iskorišćeno kao osnova za parametarsku analizu na
višespratnim i višebrodnim ramovima, kao i na primeru
zgrade. Promena krutosti i dinamičkih karakteristika je
analizirano kao i odgovor pri zemljotresnom dejstvu.
Izvršeno je poređenje sa praznom ramovskom
konstrukcijom kao i ramovima ispunjenim ispunom na
tradicionalni način. Rezultati pokazuju da je ponašanje
ramova sa izolovanom ispunom slično ponašanju praznih
ramova, dok je ponašanje ramova sa tradicionalnom
ispunom daleko drugačije i zahteva kompleksne
numeričke modele. Ovo znači da ukoliko se primeni
adekvatna konstruktivna mera izolacije ispune, proračun
ramovskim zgrada sa zidanom ispunom se može
značajno pojednostaviti.