Refine
Year of publication
- 2024 (2)
- 2023 (14)
- 2022 (16)
- 2021 (11)
- 2020 (13)
- 2019 (17)
- 2018 (18)
- 2017 (12)
- 2016 (36)
- 2015 (30)
- 2014 (31)
- 2013 (29)
- 2012 (27)
- 2011 (28)
- 2010 (26)
- 2009 (24)
- 2008 (16)
- 2007 (20)
- 2006 (17)
- 2005 (20)
- 2004 (15)
- 2003 (14)
- 2002 (19)
- 2001 (18)
- 2000 (12)
- 1999 (16)
- 1998 (31)
- 1997 (25)
- 1996 (19)
- 1995 (36)
- 1994 (29)
- 1993 (21)
- 1992 (27)
- 1991 (15)
- 1990 (20)
- 1989 (20)
- 1988 (19)
- 1987 (16)
- 1986 (11)
- 1985 (7)
- 1984 (10)
- 1983 (10)
- 1982 (3)
- 1981 (3)
- 1980 (3)
- 1979 (8)
- 1978 (2)
- 1976 (2)
- 1975 (3)
- 1973 (2)
- 1972 (2)
- 1971 (2)
Document Type
- Article (597)
- Patent (117)
- Book (65)
- Conference Proceeding (34)
- Part of a Book (21)
- Report (5)
- Bachelor Thesis (3)
- Doctoral Thesis (3)
- Diploma Thesis (1)
- Preprint (1)
Language
- English (534)
- German (310)
- Multiple languages (2)
- Spanish (1)
Keywords
- Heparin (3)
- Bacillaceae (2)
- Biorefinery (2)
- Biotechnological application (2)
- Chemometrics (2)
- IR spectroscopy (2)
- NMR spectroscopy (2)
- Principal component analysis (2)
- Standardization (2)
- Subtilases (2)
- Subtilisin (2)
- bubble column (2)
- methanation (2)
- plug flow reactor (2)
- qNMR (2)
- (Poly)saccharides (1)
- (R)- or (S)- gamma-valerolactone (1)
- 4-hydroxy valeric acid (1)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
Institute
- Fachbereich Chemie und Biotechnologie (847) (remove)
Living cells are complex biological systems transforming metabolites taken up from the surrounding medium. Monitoring the responses of such cells to certain substrate concentrations is a challenging task and offers possibilities to gain insight into the vitality of a community influenced by the growth environment. Cell-based sensors represent a promising platform for monitoring the metabolic activity and thus, the “welfare” of relevant organisms. In the present study, metabolic responses of the model bacterium Escherichia coli in suspension, layered onto a capacitive field-effect structure, were examined to pulses of glucose in the concentration range between 0.05 and 2 mM. It was found that acidification of the surrounding medium takes place immediately after glucose addition and follows Michaelis–Menten kinetic behavior as a function of the glucose concentration. In future, the presented setup can, therefore, be used to study substrate specificities on the enzymatic level and may as well be used to perform investigations of more complex metabolic responses. Conclusions and perspectives highlighting this system are discussed.
A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses.
Biopharmaceuticals such as antibodies are produced in cultivated mammalian cells, which must be monitored to comply with good manufacturing practice. We, therefore, developed a fully automated system comprising a specific exhaust gas analyzer, inline analytics and a corresponding algorithm to precisely determine the oxygen uptake rate, carbon dioxide evolution rate, carbon dioxide transfer rate, transfer quotient and respiratory quotient without interrupting the ongoing cultivation, in order to assess its reproducibility. The system was verified using chemical simulation experiments and was able to measure the respiratory activity of hybridoma cells and DG44 cells (derived from Chinese hamster ovary cells) with satisfactory results at a minimum viable cell density of ~2.0 × 10⁵ cells ml⁻¹. The system was suitable for both batch and fed-batch cultivations in bubble-aerated and membrane-aerated reactors, with and without the control of pH and dissolved oxygen.
Poly(vinyl acetate), PVAc, with a degree of polymerization Xn = 10 was prepared by chain-transfer radical polymerization using carbon tetrachloride and used as oligomeric plasticizer for commercial PVAc. However, the chlorinated chain ends cause a low thermal stability requiring mild Cl/H substitution. The product exhibits high thermal stability and excellent melt-compounding properties. Blends of oligomeric and commercial PVAc show single glass transition temperatures which decrease with higher oligomer content and exhibit small negative deviations from Fox' linear additivity rule. This indicates plasticization and miscibility being mainly due to entropic effects. Injection-moulded thick specimens show ductile behaviour at oligomer contents >10 wt %, while sheets with a thickness of 0.2–0.5 mm appear flexible already at 7.5 wt %. The oxygen permeability coefficients are an order of magnitude lower than those of low-density polyethylene. Due to the sum of their properties, the plasticized sheets present a promising alternative in the preparation of barrier materials.