Article
Refine
Year of publication
- 2022 (33) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (33) (remove)
Language
- English (33) (remove)
Document Type
- Article (33) (remove)
Keywords
- damage (2)
- Alzheimer's disease (1)
- Biocomposites (1)
- Biomechanical simulation (1)
- Bootstrapping (1)
- Boundary integral equations (1)
- Categorial variable (1)
- Cementoblast (1)
- Collective risk model (1)
- Compression (1)
- Concomitant (1)
- Conductive boundary condition (1)
- ES-FEM (1)
- Empirical process (1)
- FS-FEM (1)
- Finite element analysis (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Haemodialysis (1)
- Handbike (1)
- Heterostructure (1)
- Image Reconstruction (1)
- Independence test (1)
- Inverse spectral problem (1)
- Machine learning (1)
- Mechanotransduction (1)
- Metascintillator (1)
- Microcirculation (1)
- Mild cognitive impairment (1)
- Multiple TOF kernels (1)
- Myocardial infarction and cardiac death (1)
- Natural fibres (1)
- Paralympic sport (1)
- Polymer-matrix composites (1)
- Proximal humerus fracture (1)
- Pulsations (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Rotator cuff (1)
- S-FEM (1)
- Stress concentrations (1)
- TOF PET (1)
- Tension (1)
- Transmission eigenvalues (1)
- Vasomotions (1)
- adipose-derived stromal cells (ASCs) (1)
- anaesthetic complications (1)
- anisotropy (1)
- aortic perfusion (1)
- atomic layer deposition (1)
- biaxial tensile experiment (1)
- biocompatible materials (1)
- biodegradable electronic devices (1)
- biopotential electrodes (1)
- biosensors (1)
- bootstrap (1)
- capacitive field-effect sensors (1)
- carbon electrodes (1)
- cell aerosolization (1)
- cell atomization (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- cognitive impairment (1)
- computational fluid dynamics analysis (1)
- constitutive modeling (1)
- correlation (1)
- dental trauma (1)
- dialysis (1)
- difficult airway (1)
- distorted element (1)
- double-lumen tube intubation (1)
- endoluminal (1)
- extracorporeal membrane oxygenation (1)
- force generation (1)
- forehead EEG (1)
- glucose (1)
- high-intensity exercise (1)
- hyperelastic (1)
- impedance spectroscopy (1)
- in-ear EEG (1)
- limit analysis (1)
- muscle fascicle behavior (1)
- non-simplex S-FEM elements (1)
- pH sensors (1)
- performance testing (1)
- reliability of structures (1)
- retinal vessels (1)
- sEMG (1)
- shakedown analysis (1)
- simulation (1)
- smooth muscle contraction (1)
- stochastic programming (1)
- strain energy function (1)
- survival (1)
- tendon rupture (1)
- tri-lineage differentiation (1)
- twin-fluid atomizer (1)
- ultrasound imaging (1)
- ultrathin gate insulators (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- walking gait (1)
Objective
Hemodialysis patients show an approximately threefold higher prevalence of cognitive impairment compared to the age-matched general population. Impaired microcirculatory function is one of the assumed causes. Dynamic retinal vessel analysis is a quantitative method for measuring neurovascular coupling and microvascular endothelial function. We hypothesize that cognitive impairment is associated with altered microcirculation of retinal vessels.
Methods
152 chronic hemodialysis patients underwent cognitive testing using the Montreal Cognitive Assessment. Retinal microcirculation was assessed by Dynamic Retinal Vessel Analysis, which carries out an examination recording retinal vessels' reaction to a flicker light stimulus under standardized conditions.
Results
In unadjusted as well as in adjusted linear regression analyses a significant association between the visuospatial executive function domain score of the Montreal Cognitive Assessment and the maximum arteriolar dilation as response of retinal arterioles to the flicker light stimulation was obtained.
Conclusion
This is the first study determining retinal microvascular function as surrogate for cerebral microvascular function and cognition in hemodialysis patients. The relationship between impairment in executive function and reduced arteriolar reaction to flicker light stimulation supports the involvement of cerebral small vessel disease as contributing factor for the development of cognitive impairment in this patient population and might be a target for noninvasive disease monitoring and therapeutic intervention.
Retinal vessels are similar to cerebral vessels in their structure and function. Moderately low oscillation frequencies of around 0.1 Hz have been reported as the driving force for paravascular drainage in gray matter in mice and are known as the frequencies of lymphatic vessels in humans. We aimed to elucidate whether retinal vessel oscillations are altered in Alzheimer's disease (AD) at the stage of dementia or mild cognitive impairment (MCI). Seventeen patients with mild-to-moderate dementia due to AD (ADD); 23 patients with MCI due to AD, and 18 cognitively healthy controls (HC) were examined using Dynamic Retinal Vessel Analyzer. Oscillatory temporal changes of retinal vessel diameters were evaluated using mathematical signal analysis. Especially at moderately low frequencies around 0.1 Hz, arterial oscillations in ADD and MCI significantly prevailed over HC oscillations and correlated with disease severity. The pronounced retinal arterial vasomotion at moderately low frequencies in the ADD and MCI groups would be compatible with the view of a compensatory upregulation of paravascular drainage in AD and strengthen the amyloid clearance hypothesis.
Dynamic retinal vessel analysis (DVA) provides a non-invasive way to assess microvascular function in patients and potentially to improve predictions of individual cardiovascular (CV) risk. The aim of our study was to use untargeted machine learning on DVA in order to improve CV mortality prediction and identify corresponding response alterations.