Refine
Year of publication
- 2014 (166) (remove)
Document Type
- Article (93)
- Conference Proceeding (51)
- Part of a Book (14)
- Book (3)
- Doctoral Thesis (1)
- Master's Thesis (1)
- Patent (1)
- Poster (1)
- Report (1)
Language
- English (166) (remove)
Keywords
- Antarctic Glaciology (1)
- Bloom Taxonomy (1)
- Bone sawing (1)
- COMSOL Multiphysics (1)
- Calorimetric gas sensor (1)
- Cryptographic protocols (1)
- DNA hybridization (1)
- Extraterrestrial Glaciology (1)
- Field-effect sensor (1)
- Glaciological instruments and methods (1)
- Hydrogen peroxide (1)
- LAPS (1)
- Light-addressable Potentiometric Sensor (1)
- LiveLink for MATLAB (1)
- Malicious model (1)
- Multi-sensor system (1)
- Optimization module (1)
- Privacy-enhancing technologies (1)
- Secure multi-party computation (1)
- Subclacial exploration (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (58)
- INB - Institut für Nano- und Biotechnologien (34)
- Fachbereich Chemie und Biotechnologie (24)
- Fachbereich Elektrotechnik und Informationstechnik (24)
- IfB - Institut für Bioengineering (24)
- Fachbereich Energietechnik (22)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Wirtschaftswissenschaften (6)
- Fachbereich Bauingenieurwesen (4)
- Solar-Institut Jülich (4)
- Fachbereich Maschinenbau und Mechatronik (3)
- Sonstiges (3)
- ECSM European Center for Sustainable Mobility (1)
- Institut fuer Angewandte Polymerchemie (1)
Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome.
Shakedown analysis of Reissner-Mindlin plates using the edge-based smoothed finite element method
(2014)
This paper concerns the development of a primal-dual algorithm for limit and shakedown analysis of Reissner-Mindlin plates made of von Mises material. At each optimization iteration, the lower bound of the shakedown load multiplier is calculated simultaneously with the upper bound using the duality theory. An edge-based smoothed finite element method (ES-FEM) combined with the discrete shear gap (DSG) technique is used to improve the accuracy of the solutions and to avoid the transverse shear locking behaviour. The method not only possesses all inherent features of convergence and accuracy from ES-FEM, but also ensures that the total number of variables in the optimization problem is kept to a minimum compared with the standard finite element formulation. Numerical examples are presented to demonstrate the effectiveness of the present method.
Biopharmaceuticals such as antibodies are produced in cultivated mammalian cells, which must be monitored to comply with good manufacturing practice. We, therefore, developed a fully automated system comprising a specific exhaust gas analyzer, inline analytics and a corresponding algorithm to precisely determine the oxygen uptake rate, carbon dioxide evolution rate, carbon dioxide transfer rate, transfer quotient and respiratory quotient without interrupting the ongoing cultivation, in order to assess its reproducibility. The system was verified using chemical simulation experiments and was able to measure the respiratory activity of hybridoma cells and DG44 cells (derived from Chinese hamster ovary cells) with satisfactory results at a minimum viable cell density of ~2.0 × 10⁵ cells ml⁻¹. The system was suitable for both batch and fed-batch cultivations in bubble-aerated and membrane-aerated reactors, with and without the control of pH and dissolved oxygen.
This article describes the fabrication, characterization and application of an epidermal temporary-transfer tattoo-based potentiometric sensor, coupled with a miniaturized wearable wireless transceiver, for real-time monitoring of sodium in the human perspiration. Sodium excreted during perspiration is an excellent marker for electrolyte imbalance and provides valuable information regarding an individual's physical and mental wellbeing. The realization of the new skin-worn non-invasive tattoo-like sensing device has been realized by amalgamating several state-of-the-art thick film, laser printing, solid-state potentiometry, fluidics and wireless technologies. The resulting tattoo-based potentiometric sodium sensor displays a rapid near-Nernstian response with negligible carryover effects, and good resiliency against various mechanical deformations experienced by the human epidermis. On-body testing of the tattoo sensor coupled to a wireless transceiver during exercise activity demonstrated its ability to continuously monitor sweat sodium dynamics. The real-time sweat sodium concentration was transmitted wirelessly via a body-worn transceiver from the sodium tattoo sensor to a notebook while the subjects perspired on a stationary cycle. The favorable analytical performance along with the wearable nature of the wireless transceiver makes the new epidermal potentiometric sensing system attractive for continuous monitoring the sodium dynamics in human perspiration during diverse activities relevant to the healthcare, fitness, military, healthcare and skin-care domains.
Poly(vinyl acetate), PVAc, with a degree of polymerization Xn = 10 was prepared by chain-transfer radical polymerization using carbon tetrachloride and used as oligomeric plasticizer for commercial PVAc. However, the chlorinated chain ends cause a low thermal stability requiring mild Cl/H substitution. The product exhibits high thermal stability and excellent melt-compounding properties. Blends of oligomeric and commercial PVAc show single glass transition temperatures which decrease with higher oligomer content and exhibit small negative deviations from Fox' linear additivity rule. This indicates plasticization and miscibility being mainly due to entropic effects. Injection-moulded thick specimens show ductile behaviour at oligomer contents >10 wt %, while sheets with a thickness of 0.2–0.5 mm appear flexible already at 7.5 wt %. The oxygen permeability coefficients are an order of magnitude lower than those of low-density polyethylene. Due to the sum of their properties, the plasticized sheets present a promising alternative in the preparation of barrier materials.
We study the estimation of some linear functionals which are based on an unknown lifetime distribution. The observations are assumed to be generated under the semi-parametric random censorship model (SRCM), that is, a random censorship model where the conditional expectation of the censoring indicator given the observation belongs to a parametric family. Under this setup a semi-parametric estimator of the survival function was introduced by the author. If the parametric model assumption is correct, it is known that the estimated functional which is based on this semi-parametric estimator is asymptotically at least as efficient as the corresponding one which rests on the nonparametric Kaplan–Meier estimator.
In this paper we show that the estimated functional which is based on this semi-parametric estimator is asymptotically efficient with respect to the class of all regular estimators under this semi-parametric model.
In this study, a high-speed chemical imaging system was developed for visualization of the interior of a microfluidic channel. A microfluidic channel was constructed on the sensor surface of the light-addressable potentiometric sensor (LAPS), on which the ion concentrations could be measured in parallel at up to 64 points illuminated by optical fibers. The temporal change of pH distribution inside the microfluidic channel was recorded at a maximum rate of 100 frames per second (fps). The high frame rate allowed visualization of moving interfaces and plugs in the channel even at a flow velocity of 111 mm/s, which suggests the feasibility of plug-based microfluidic devices for flow-injection analysis (FIA).
An enzyme system organized in a flow device was used to mimic a reversible Controlled NOT (CNOT) gate with two input and two output signals. Reversible conversion of NAD⁺ and NADH cofactors was used to perform a XOR logic operation, while biocatalytic hydrolysis of p-nitrophenyl phosphate resulted in an Identity operation working in parallel. The first biomolecular realization of a CNOT gate is promising for integration into complex biomolecular networks and future biosensor/biomedical applications.
The composition and physiochemical properties of aquatic-phase natural organic matter (NOM) are most important problems for both environmental studies and water industry. Laser desorption/ionization (LDI) mass spectrometry facilitated successful examinations of NOM, as humic and fulvic acids in NOM are readily ionized by the nitrogen laser. In this study, hydrophobic NOMs (HPO NOMs) from river, reservoir and waste water were characterized by this technique. The effect of analytical variables like concentration, solvent composition and laser energy was investigated. The exact masses of small molecular NOM moieties in the range of 200–1200 m/z were determined in reflectron mode. In addition, spectra of post-source-decay experiments in this range showed that some compounds from different natural NOMs had the same fragmental ions. In the large mass range of 1200–15 000 Da, macromolecules and their aggregates were found in HPO NOMs from natural waters. Highly humic HPO exhibited mass peaks larger than 8000 Da. On the other hand, the waste water and reservoir water mainly had relatively smaller molecules of about 2000 Da. The LDI-MS measurements indicated that highly humic river waters were able to form large aggregates and membrane foulants, while the HPO NOMs from waste water and reservoir water were unlikely to form large aggregates. Copyright © 2014 John Wiley & Sons, Ltd.
The Gram-positive endospore-forming bacterium Bacillus licheniformis can be found widely in nature and it is exploited in industrial processes for the manufacturing of antibiotics, specialty chemicals, and enzymes. Both in its varied natural habitats and in industrial settings, B. licheniformis cells will be exposed to increases in the external osmolarity, conditions that trigger water efflux, impair turgor, cause the cessation of growth, and negatively affect the productivity of cell factories in biotechnological processes. We have taken here both systems-wide and targeted physiological approaches to unravel the core of the osmostress responses of B. licheniformis. Cells were suddenly subjected to an osmotic upshift of considerable magnitude (with 1 M NaCl), and their transcriptional profile was then recorded in a time-resolved fashion on a genome-wide scale. A bioinformatics cluster analysis was used to group the osmotically up-regulated genes into categories that are functionally associated with the synthesis and import of osmostress-relieving compounds (compatible solutes), the SigB-controlled general stress response, and genes whose functional annotation suggests that salt stress triggers secondary oxidative stress responses in B. licheniformis. The data set focusing on the transcriptional profile of B. licheniformis was enriched by proteomics aimed at identifying those proteins that were accumulated by the cells through increased biosynthesis in response to osmotic stress. Furthermore, these global approaches were augmented by a set of experiments that addressed the synthesis of the compatible solutes proline and glycine betaine and assessed the growth-enhancing effects of various osmoprotectants. Combined, our data provide a blueprint of the cellular adjustment processes of B. licheniformis to both sudden and sustained osmotic stress.