Conference Proceeding
Refine
Year of publication
Document Type
- Conference Proceeding (1146) (remove)
Language
- English (1146) (remove)
Keywords
- Biosensor (25)
- CAD (7)
- Finite-Elemente-Methode (7)
- civil engineering (7)
- Bauingenieurwesen (6)
- Blitzschutz (6)
- Enterprise Architecture (5)
- Clusterion (4)
- Energy storage (4)
- Gamification (4)
- Leadership (4)
- Limit analysis (4)
- Natural language processing (4)
- Power plants (4)
- Sonde (4)
- Telekommunikationsmarkt (4)
- hydrogen (4)
- solar sail (4)
- Air purification (3)
- Associated liquids (3)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (230)
- Fachbereich Medizintechnik und Technomathematik (208)
- Fachbereich Luft- und Raumfahrttechnik (178)
- Fachbereich Energietechnik (177)
- IfB - Institut für Bioengineering (147)
- Solar-Institut Jülich (110)
- Fachbereich Maschinenbau und Mechatronik (107)
- Fachbereich Bauingenieurwesen (73)
- Fachbereich Wirtschaftswissenschaften (51)
- ECSM European Center for Sustainable Mobility (50)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (46)
- INB - Institut für Nano- und Biotechnologien (39)
- Fachbereich Chemie und Biotechnologie (23)
- Kommission für Forschung und Entwicklung (16)
- Nowum-Energy (11)
- Fachbereich Architektur (7)
- Fachbereich Gestaltung (4)
- Institut fuer Angewandte Polymerchemie (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between “floor” and “roof” in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived.