Refine
Year of publication
- 2023 (237) (remove)
Document Type
- Bachelor Thesis (93)
- Article (68)
- Conference Proceeding (30)
- Part of a Book (22)
- Book (10)
- Master's Thesis (2)
- Patent (2)
- Preprint (2)
- Talk (2)
- Contribution to a Periodical (1)
- Habilitation (1)
- Other (1)
- Part of Periodical (1)
- Report (1)
- Administrative publication (1)
Keywords
- Corporate Design (6)
- Editorial (6)
- Illustration (6)
- Typografie (6)
- Nachhaltigkeit (5)
- Produktdesign (5)
- Fotografie (4)
- Publikation (4)
- Design (3)
- Erscheinungsbild (3)
- Information extraction (3)
- Kinder (3)
- Künstliche Intelligenz (3)
- Museum (3)
- Natural language processing (3)
- nachhaltig (3)
- Animation (2)
- Architektur (2)
- Associated liquids (2)
- Bacillaceae (2)
Institute
- Fachbereich Gestaltung (95)
- Fachbereich Medizintechnik und Technomathematik (38)
- Fachbereich Elektrotechnik und Informationstechnik (23)
- ECSM European Center for Sustainable Mobility (21)
- Fachbereich Luft- und Raumfahrttechnik (20)
- Fachbereich Wirtschaftswissenschaften (17)
- Fachbereich Chemie und Biotechnologie (14)
- Fachbereich Energietechnik (14)
- INB - Institut für Nano- und Biotechnologien (12)
- Fachbereich Maschinenbau und Mechatronik (10)
- IfB - Institut für Bioengineering (9)
- Nowum-Energy (7)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (6)
- Fachbereich Bauingenieurwesen (5)
- Kommission für Forschung und Entwicklung (3)
- Solar-Institut Jülich (3)
- FH Aachen (2)
- Fachbereich Architektur (2)
- Institut fuer Angewandte Polymerchemie (2)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
The increasing share of renewable electricity in the grid drives the need for sufficient storage capacity. Especially for seasonal storage, power-to-gas can be a promising approach. Biologically produced methane from hydrogen produced from surplus electricity can be used to substitute natural gas in the existing infrastructure. Current reactor types are not or are poorly optimized for flexible methanation. Therefore, this work proposes a new reactor type with a plug flow reactor (PFR) design. Simulations in COMSOL Multiphysics ® showed promising properties for operation in laminar flow. An experiment was conducted to support the simulation results and to determine the gas fraction of the novel reactor, which was measured to be 29%. Based on these simulations and experimental results, the reactor was constructed as a 14 m long, 50 mm diameter tube with a meandering orientation. Data processing was established, and a step experiment was performed. In addition, a kLa of 1 h−1 was determined. The results revealed that the experimental outcomes of the type of flow and gas fractions are in line with the theoretical simulation. The new design shows promising properties for flexible methanation and will be tested.
Modern implementations of driver assistance systems are evolving from a pure driver assistance to a independently acting automation system. Still these systems are not covering the full vehicle usage range, also called operational design domain, which require the human driver as fall-back mechanism. Transition of control and potential minimum risk manoeuvres are currently research topics and will bridge the gap until full autonomous vehicles are available. The authors showed in a demonstration that the transition of control mechanisms can be further improved by usage of communication technology. Receiving the incident type and position information by usage of standardised vehicle to everything (V2X) messages can improve the driver safety and comfort level. The connected and automated vehicle’s software framework can take this information to plan areas where the driver should take back control by initiating a transition of control which can be followed by a minimum risk manoeuvre in case of an unresponsive driver. This transition of control has been implemented in a test vehicle and was presented to the public during the IEEE IV2022 (IEEE Intelligent Vehicle Symposium) in Aachen, Germany.
Die Auswahl der passenden Geschäftsprozesse für eine Automatisierung mittels Robotic Process Automation (RPA) ist für den Erfolg von RPA-Projekten entscheidend. Das vorliegende Kapitel liefert dafür Selektionskriterien, die aus einer qualitativen Studie mit elf interviewten RPA-Experten aus dem Versicherungsumfeld resultieren. Das Ergebnis umfasst eine gewichtete Liste von sieben Dimensionen und 51 Prozesskriterien, welche die Automatisierung mit Softwarerobotern begünstigen beziehungsweise deren Nichterfüllung eine Umsetzung erschweren oder sogar verhindern. Die drei wichtigsten Kriterien zur Auswahl von Geschäftsprozessen für die Automatisierung mittels RPA umfassen die Entlastung der an dem Prozess mitwirkenden Mitarbeiter (Arbeitnehmerentlastung), die Ausführbarkeit des Prozesses mittels Regeln (Regelbasierte Prozessteuerung) sowie ein positiver Kosten-Nutzen-Vergleich. Auf diesen Ergebnissen aufbauend wird ein Vergleich mit den bereits bekannten Selektionskriterien aus der Literatur erstellt und diskutiert. Praktiker können die Ergebnisse verwenden, um eine systematische Auswahl von RPA-relevanten Prozessen vorzunehmen. Aus wissenschaftlicher Perspektive stellen die Ergebnisse eine Grundlage zur Erklärung des Erfolgs und Misserfolgs von RPA-Projekten dar.
A method for detecting and approximating fault lines or surfaces, respectively, or decision curves in two and three dimensions with guaranteed accuracy is presented. Reformulated as a classification problem, our method starts from a set of scattered points along with the corresponding classification algorithm to construct a representation of a decision curve by points with prescribed maximal distance to the true decision curve. Hereby, our algorithm ensures that the representing point set covers the decision curve in its entire extent and features local refinement based on the geometric properties of the decision curve. We demonstrate applications of our method to problems related to the detection of faults, to multi-criteria decision aid and, in combination with Kirsch’s factorization method, to solving an inverse acoustic scattering problem. In all applications we considered in this work, our method requires significantly less pointwise classifications than previously employed algorithms.
Deammonification for nitrogen removal in municipal wastewater in temperate and cold climate zones is currently limited to the side stream of municipal wastewater treatment plants (MWWTP). This study developed a conceptual model of a mainstream deammonification plant, designed for 30,000 P.E., considering possible solutions corresponding to the challenging mainstream conditions in Germany. In addition, the energy-saving potential, nitrogen elimination performance and construction-related costs of mainstream deammonification were compared to a conventional plant model, having a single-stage activated sludge process with upstream denitrification. The results revealed that an additional treatment step by combining chemical precipitation and ultra-fine screening is advantageous prior the mainstream deammonification. Hereby chemical oxygen demand (COD) can be reduced by 80% so that the COD:N ratio can be reduced from 12 to 2.5. Laboratory experiments testing mainstream conditions of temperature (8–20°C), pH (6–9) and COD:N ratio (1–6) showed an achievable volumetric nitrogen removal rate (VNRR) of at least 50 gN/(m3∙d) for various deammonifying sludges from side stream deammonification systems in the state of North Rhine-Westphalia, Germany, where m3 denotes reactor volume. Assuming a retained Norganic content of 0.0035 kgNorg./(P.E.∙d) from the daily loads of N at carbon removal stage and a VNRR of 50 gN/(m3∙d) under mainstream conditions, a resident-specific reactor volume of 0.115 m3/(P.E.) is required for mainstream deammonification. This is in the same order of magnitude as the conventional activated sludge process, i.e., 0.173 m3/(P.E.) for an MWWTP of size class of 4. The conventional plant model yielded a total specific electricity demand of 35 kWh/(P.E.∙a) for the operation of the whole MWWTP and an energy recovery potential of 15.8 kWh/(P.E.∙a) through anaerobic digestion. In contrast, the developed mainstream deammonification model plant would require only a 21.5 kWh/(P.E.∙a) energy demand and result in 24 kWh/(P.E.∙a) energy recovery potential, enabling the mainstream deammonification model plant to be self-sufficient. The retrofitting costs for the implementation of mainstream deammonification in existing conventional MWWTPs are nearly negligible as the existing units like activated sludge reactors, aerators and monitoring technology are reusable. However, the mainstream deammonification must meet the performance requirement of VNRR of about 50 gN/(m3∙d) in this case.
Background
Post-COVID-19 syndrome (PCS) is a lingering disease with ongoing symptoms such as fatigue and cognitive impairment resulting in a high impact on the daily life of patients. Understanding the pathophysiology of PCS is a public health priority, as it still poses a diagnostic and treatment challenge for physicians.
Methods
In this prospective observational cohort study, we analyzed the retinal microcirculation using Retinal Vessel Analysis (RVA) in a cohort of patients with PCS and compared it to an age- and gender-matched healthy cohort (n = 41, matched out of n = 204).
Measurements and main results
PCS patients exhibit persistent endothelial dysfunction (ED), as indicated by significantly lower venular flicker-induced dilation (vFID; 3.42% ± 1.77% vs. 4.64% ± 2.59%; p = 0.02), narrower central retinal artery equivalent (CRAE; 178.1 [167.5–190.2] vs. 189.1 [179.4–197.2], p = 0.01) and lower arteriolar-venular ratio (AVR; (0.84 [0.8–0.9] vs. 0.88 [0.8–0.9], p = 0.007). When combining AVR and vFID, predicted scores reached good ability to discriminate groups (area under the curve: 0.75). Higher PCS severity scores correlated with lower AVR (R = − 0.37 p = 0.017). The association of microvascular changes with PCS severity were amplified in PCS patients exhibiting higher levels of inflammatory parameters.
Conclusion
Our results demonstrate that prolonged endothelial dysfunction is a hallmark of PCS, and impairments of the microcirculation seem to explain ongoing symptoms in patients. As potential therapies for PCS emerge, RVA parameters may become relevant as clinical biomarkers for diagnosis and therapy management.
Preprint: Studies on the enzymatic reduction of levulinic acid using Chiralidon-R and Chiralidon-S
(2023)
The enzymatic reduction of levulinic acid by the chiral catalysts Chiralidon-R and Chiralidon-S which are commercially available superabsorbed alcohol dehydrogenases is described. The Chiralidon®-R/S reduces the levulinic acid to the (R,S)-4-hydroxy valeric acid and the (R)- or (S)- gamma-valerolactone.
Die Verfasser stellen in ihrem Beitrag die künftig in Kraft tretenden oder schon in Kraft getretenen Gesetzesvorhaben der europäischen Union vor. Vorab werde auf die abgelaufene Frist zur Anpassung von Standardvertragsklausel hingewiesen. Die Anpassung könne ggf. durch den Data Privacy Act der Kommission bewirkt werden, da dieser eine Angemessenheit suggeriere. Neben dem Digital Markets Act, der die Wahrung der Diskriminierungsfreiheit den Gatekeeper-Plattformen bezüglich der Bewerbung von Waren Dritter vorschreibt, sind ebenfalls der Digital Service Act und der Data Governance Act in Kraft getreten und werden künftig wirksam. Letzteres bezweckt den Datenaustausch von nicht-personenbezogenen Daten öffentlich-rechtlicher Datensätze, wobei anders als bei DSA, der die Verbraucherrechte durchsetzen möchte, mangels Verpflichtung die praktische Umsetzung ausbleiben werde. In der Entwurfsphase stecken der Artificial Intelligence Act, der Data Act, sowie der Cyber Resilience Act. Allen drei sei wegen dem weiten Anwendungsspielraum, der Bußgeldandrohung oder der Cyber-Bedrohungslage besondere praktische Relevanz beizumessen. Die Kommission weite durch diese Gesetzesvorhaben ihre Regelungsabsicht auch auf nicht-personenbezogene Daten und dem Datentransfer aus. Im Ergebnis werden die Unternehmen mit mehr Verpflichtungen konfrontiert, zu dessen Umsetzung ein funktionierendes Compliance-Management-System unabdingbar sei.