Refine
Year of publication
- 2020 (245) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (59)
- Fachbereich Energietechnik (35)
- Fachbereich Wirtschaftswissenschaften (35)
- Fachbereich Luft- und Raumfahrttechnik (33)
- IfB - Institut für Bioengineering (33)
- Fachbereich Elektrotechnik und Informationstechnik (29)
- ECSM European Center for Sustainable Mobility (19)
- Fachbereich Maschinenbau und Mechatronik (18)
- Fachbereich Bauingenieurwesen (14)
- Solar-Institut Jülich (14)
Language
- English (172)
- German (71)
- Multiple languages (1)
- Dutch (1)
Document Type
- Article (135)
- Conference Proceeding (55)
- Part of a Book (20)
- Book (9)
- Review (7)
- Other (4)
- Doctoral Thesis (3)
- Patent (3)
- Administrative publication (3)
- Conference Poster (2)
- Conference: Meeting Abstract (1)
- Contribution to a Periodical (1)
- Part of a Periodical (1)
- Report (1)
Keywords
- Amtliche Mitteilung (3)
- MINLP (3)
- Additive manufacturing (2)
- Adjacent buildings (2)
- Experimental validation (2)
- Historical centres (2)
- INODIS (2)
- SIJ (2)
- Shake table test (2)
- Solar-Institut Jülich (2)
Is part of the Bibliography
- no (245)
Design, evaluation and comparison of endorectal coils for hybrid MR-PET imaging of the prostate
(2020)
Prostate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexible and can move into different positions under external conditions, it is important to localise the focused region-of-interest using both MRI and PET under identical circumstances. In this work, we designed five commonly used linear and quadrature radiofrequency surface coils suitable for hybrid MR-PET use in endorectal applications. Due to the endorectal design and the shielded PET insert, the outer face of the coils investigated was curved and the region to be imaged was outside the volume of the coil. The tilting angles of the coils were varied with respect to the main magnetic field direction. This was done to approximate the various positions from which the prostate could be imaged. The transmit efficiencies and safety excitation efficiencies from simulations, together with the signal-to-noise ratios from the MR images were calculated and analysed. Overall, it was found that the overlapped loops driven in quadrature were superior to the other types of coils we tested. In order to determine the effect of the different coil designs on PET, transmission scans were carried out, and it was observed that the differences between attenuation maps with and without the coils were negligible. The findings of this work can provide useful guidance for the integration of such coil designs into MR-PET hybrid systems in the future.
In this chapter, the key technologies and the instrumentation required for the subsurface exploration of ocean worlds are discussed. The focus is laid on Jupiter’s moon Europa and Saturn’s moon Enceladus because they have the highest potential for such missions in the near future. The exploration of their oceans requires landing on the surface, penetrating the thick ice shell with an ice-penetrating probe, and probably diving with an underwater vehicle through dozens of kilometers of water to the ocean floor, to have the chance to find life, if it exists. Technologically, such missions are extremely challenging. The required key technologies include power generation, communications, pressure resistance, radiation hardness, corrosion protection, navigation, miniaturization, autonomy, and sterilization and cleaning. Simpler mission concepts involve impactors and penetrators or – in the case of Enceladus – plume-fly-through missions.
Large scale central receiver systems typically deploy between thousands to more than a hundred thousand heliostats. During solar operation, each heliostat is aligned individually in such a way that the overall surface normal bisects the angle between the sun’s position and the aim point coordinate on the receiver. Due to various tracking error sources, achieving accurate alignment ≤1 mrad for all the heliostats with respect to the aim points on the receiver without a calibration system can be regarded as unrealistic. Therefore, a calibration system is necessary not only to improve the aiming accuracy for achieving desired flux distributions but also to reduce or eliminate spillage. An overview of current larger-scale central receiver systems (CRS), tracking error sources and the basic requirements of an ideal calibration system is presented. Leading up to the main topic, a description of general and specific terms on the topics heliostat calibration and tracking control clarifies the terminology used in this work. Various figures illustrate the signal flows along various typical components as well as the corresponding monitoring or measuring devices that indicate or measure along the signal (or effect) chain. The numerous calibration systems are described in detail and classified in groups. Two tables allow the juxtaposition of the calibration methods for a better comparison. In an assessment, the advantages and disadvantages of individual calibration methods are presented.
The application of atomic layer deposition in the production of sorbents for ⁹⁹Mo/⁹⁹ᵐTc generator
(2020)
New production routes for ⁹⁹Mo are steadily gaining importance. However, the obtained specific activity is much lower than currently produced by the fission of U-235. To be able to supply hospitals with ⁹⁹Mo/⁹⁹ᵐTc generators with the desired activity, the adsorption capacity of the column material should be increased. In this paper we have investigated whether the gas phase coating technique Atomic Layer Deposition (ALD), which can deposit ultra-thin layers on high surface area materials, can be used to attain materials with high adsorption capacity for ⁹⁹Mo. For this purpose, ALD was applied on a silica-core sorbent material to coat it with a thin layer of alumina. This sorbent material shows to have a maximum adsorption capacity of 120 mg/g and has a ⁹⁹ᵐTc elution efficiency of 55 ± 2% based on 3 executive elutions.
Extracellular acidification is a basic indicator for alterations in two vital metabolic pathways: glycolysis and cellular respiration. Measuring these alterations by monitoring extracellular acidification using cell-based biosensors such as LAPS plays an important role in studying these pathways whose disorders are associated with numerous diseases including cancer. However, the surface of the biosensors must be specially tailored to ensure high cell compatibility so that cells can represent more in vivo-like behavior, which is critical to gain more realistic in vitro results from the analyses, e.g., drug discovery experiments. In this work, O2 plasma patterning on the LAPS surface is studied to enhance surface features of the sensor chip, e.g., wettability and biofunctionality. The surface treated with O2 plasma for 30 s exhibits enhanced cytocompatibility for adherent CHO–K1 cells, which promotes cell spreading and proliferation. The plasma-modified LAPS chip is then integrated into a microfluidic system, which provides two identical channels to facilitate differential measurements of the extracellular acidification of CHO–K1 cells. To the best of our knowledge, it is the first time that extracellular acidification within microfluidic channels is quantitatively visualized as differential (bio-)chemical images.
Die fortschreitende Digitalisierung und Globalisierung fordert von den Unternehmen eine erhöhte Flexibilität und Anpassungsfähigkeit. Um dies zu erreichen, sind qualifizierte und engagierte Mitarbeiter/-innen unabdingbar. Gamification bietet die Möglichkeit, Beschäftigte individuell in ihren Tätigkeiten zu unterstützen und mittels Feedbackmechanismen zu motivieren. In dieser Arbeit wird ein Gamification Konzept bestehend aus einem intelligenten Arbeitsplatz, einer Wissensdatenbank und einer Gamification Plattform vorgestellt, welches an bestehende Produktionsumgebungen adaptiert werden kann. Das Konzept wird am Beispiel der Longboardproduktion in der Industrie 4.0 Modellfabrik der FH Aachen implementiert und evaluiert.
Dargestellt und beansprucht ist eine Funkeinheit mit einem Funkbauteil, einer elektrisch leitfähigen Antenne und einem Kunststoffverbindungsmittel. Das Funkbauteil weist einen Antennenanschluss auf. Das Kunststoffverbindungsmittel weist ein erstes Elastomermaterial mit elektrisch leitfähigem Zusatzmaterial auf, so dass das Kunststoffverbindungsmittel elektrisch leitfähig ist. Das Kunststoffverbindungsmittel bildet eine mechanische und elektrisch leitfähige Verbindung zwischen dem Antennenanschluss und der Antenne. Weiterhin wird eine Vorrichtung mit einem ein Matrixmaterial mit oder aus einem zweiten Elastomermaterial und einer Funkeinheit beschrieben und beansprucht, wobei die Funkeinheit vollständig in das Matrixmaterial eingebettet ist. Die Vorrichtung kann insbesondere ein Fahrzeugreifen sein.
Sekundäre galvanische Zelle
(2020)
Die vorliegende Erfindung betrifft eine sekundäre galvanische Zelle, umfassend eine Kathode, eine Anode und einen Separator, der zwischen der Kathode und der Anode angeordnet ist, wobei die Kathode ein erstes elastomeres Polymer umfasst, welches mit einem ersten Füllstoff als Kathodenmaterial gefüllt ist, wobei die Anode ein zweites elastomeres Polymer umfasst, welches mit einem zweiten Füllstoff als Anodenmaterial gefüllt ist, wobei der Separator ein drittes elastomeres Polymer umfasst, wobei das erste elastomere Polymer, das zweite elastomere Polymer und das dritte elastomere Polymer unabhängig voneinander aus vernetzungsfähigen Dienkautschuken ausgewählt sind, und wobei zumindest eines von dem ersten elastomeren Polymer, dem zweiten elastomeren Polymer und dem dritten elastomeren Polymer eine ionische Flüssigkeit und/oder ein elektrisch leitfähiges Polymer enthält. Die vorliegende Erfindung betrifft ferner eine wiederaufladbare Batterie, umfassend die erfindungsgemäße sekundäre galvanische Zelle, ein Verfahren zur Herstellung einer sekundären galvanischen Zelle sowie die Verwendung der erfindungsgemäßen sekundären galvanischen Zelle sowie der erfindungsgemäßen wiederaufladbaren Batterie.
The Kremer–Grest (KG) polymer model is a standard model for studying generic polymer properties in molecular dynamics simulations. It owes its popularity to its simplicity and computational efficiency, rather than its ability to represent specific polymers species and conditions. Here we show that by tuning the chain stiffness it is possible to adapt the KG model to model melts of real polymers. In particular, we provide mapping relations from KG to SI units for a wide range of commodity polymers. The connection between the experimental and the KG melts is made at the Kuhn scale, i.e., at the crossover from the chemistry-specific small scale to the universal large scale behavior. We expect Kuhn scale-mapped KG models to faithfully represent universal properties dominated by the large scale conformational statistics and dynamics of flexible polymers. In particular, we observe very good agreement between entanglement moduli of our KG models and the experimental moduli of the target polymers.