Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1926)
- Fachbereich Elektrotechnik und Informationstechnik (1150)
- Fachbereich Wirtschaftswissenschaften (1119)
- Fachbereich Energietechnik (1066)
- Fachbereich Chemie und Biotechnologie (892)
- Fachbereich Maschinenbau und Mechatronik (801)
- Fachbereich Luft- und Raumfahrttechnik (768)
- Fachbereich Bauingenieurwesen (664)
- IfB - Institut für Bioengineering (625)
- INB - Institut für Nano- und Biotechnologien (585)
Has Fulltext
- no (9278) (remove)
Language
Document Type
- Article (5516)
- Conference Proceeding (1413)
- Book (1057)
- Part of a Book (555)
- Patent (174)
- Bachelor Thesis (165)
- Report (82)
- Doctoral Thesis (79)
- Conference: Meeting Abstract (75)
- Other (67)
- Contribution to a Periodical (20)
- Review (18)
- Master's Thesis (17)
- Working Paper (13)
- Conference Poster (5)
- Habilitation (5)
- Preprint (5)
- Talk (5)
- Diploma Thesis (3)
- Part of a Periodical (2)
- Examination Thesis (1)
- Video (1)
Keywords
- Illustration (10)
- Nachhaltigkeit (10)
- Corporate Design (9)
- Erscheinungsbild (8)
- Gamification (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Deutschland (6)
- Digitalisierung (6)
After menopause, decreased levels of estrogen and progesterone remodel the collagen of the soft tissues thereby reducing their stiffness. Stress urinary incontinence is associated with involuntary urine leakage due to pathological movement of the pelvic organs resulting from lax suspension system, fasciae, and ligaments. This study compares the changes in the orientation and position of the female pelvic organs due to weakened fasciae, ligaments, and their combined laxity. A mixture theory weighted by respective volume fraction of elastin-collagen fibre compound (5%), adipose tissue (85%), and smooth muscle (5%) is adopted to characterize the mechanical behaviour of the fascia. The load carrying response (other than the functional response to the pelvic organs) of each fascia component, pelvic organs, muscles, and ligaments are assumed to be isotropic, hyperelastic, and incompressible. Finite element simulations are conducted during Valsalva manoeuvre with weakened tissues modelled by reduced tissue stiffness. A significant dislocation of the urethrovesical junction is observed due to weakness of the fascia (13.89 mm) compared to the ligaments (5.47 mm). The dynamics of the pelvic floor observed in this study during Valsalva manoeuvre is associated with urethral-bladder hypermobility, greater levator plate angulation, and positive Q-tip test which are observed in incontinent females.
Pelvic floor dysfunction (PFD) is characterized by the failure of the levator ani (LA) muscle to maintain the pelvic hiatus, resulting in the descent of the pelvic organs below the pubococcygeal line. This chapter adopts the modified Humphrey material model to consider the effect of the muscle fiber on passive stretching of the LA muscle. The deformation of the LA muscle subjected to intra-abdominal pressure during Valsalva maneuver is compared with the magnetic resonance imaging (MRI) examination of a nulliparous female. Numerical result shows that the fiber-based Humphrey model simulates the muscle behavior better than isotropic constitutive models. Greater posterior movement of the LA muscle widens the levator hiatus due to lack of support from the anococcygeal ligament and the perineal structure as a consequence of birth-related injury and aging. Old and multiparous females with uncontrolled urogenital and rectal hiatus tend to develop PFDs such as prolapse and incontinence.
In this work, a spore-based biosensor is evaluated to monitor the microbicidal efficacy of sterilization processes applying gaseous hydrogen peroxide (H2O2). The sensor is based on interdigitated electrode structures (IDEs) that have been fabricated by means of thin-film technologies. Impedimetric measurements are applied to study the effect of sterilization process on spores of Bacillus atrophaeus. This resilient microorganism is commonly used in industry to proof the sterilization efficiency. The sensor measurements are accompanied by conventional microbiological challenge tests, as well as morphological characterizations with scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The sensor measurements are correlated with the microbiological test routines. In both methods, namely the sensor-based and microbiological one, a tailing effect has been observed. The results are evaluated and discussed in a three-dimensional calibration plot demonstrating the sensor's suitability to enable a rapid process decision in terms of a successfully performed sterilization.