Article
Refine
Year of publication
- 2012 (130) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (41)
- Fachbereich Wirtschaftswissenschaften (26)
- INB - Institut für Nano- und Biotechnologien (25)
- Fachbereich Elektrotechnik und Informationstechnik (16)
- Fachbereich Chemie und Biotechnologie (15)
- IfB - Institut für Bioengineering (14)
- Fachbereich Maschinenbau und Mechatronik (11)
- Fachbereich Bauingenieurwesen (5)
- Fachbereich Energietechnik (5)
- Fachbereich Architektur (3)
Document Type
- Article (130) (remove)
Keywords
- (Bio)degradation (1)
- 802.15.4 (1)
- Acceleration (1)
- Afterload (1)
- Alginate beads (1)
- Anastomotic leakage (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Avalanche (1)
- Bank-issued Warrants (1)
- Bluetooth (1)
- Borehole heat exchanger (1)
- Calorimetric gas sensor (1)
- Cell permeability (1)
- CellDrum (1)
- Cellular force (1)
- Chemical imaging sensor (1)
- Circular Dichroism (1)
- Compliance (1)
- Consensus (1)
- Contractile tension (1)
- Contractility (1)
- C–V method (1)
- Decomposition (1)
- Detergent protease (1)
- Discourse ethics (1)
- Disposition Effect (1)
- Distributed Control Systems, (1)
- Elemental (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Esophageal Doppler monitor (1)
- Extracellular enzymes (1)
- Field-effect sensor (1)
- Finite differences (1)
- Finite element modelling (1)
- Force (1)
- Freeze–thaw process (1)
- Fußball (1)
- Guerrillawerbung (1)
- Heat transport (1)
- Hydrogen peroxide (1)
- Hypersecretion (1)
- IP-based networks (1)
- Impedance spectroscopy (1)
- Individual Investors (1)
- Industrial Automation Technology, (1)
- Kinetic energy (1)
- LAPS (1)
- Light-addressable potentiometric sensor (1)
- Lipopolysaccharide (1)
- Liver (1)
- Low-field NMR (1)
- Marker-free mutagenesis (1)
- NGN (1)
- NMR exchange relaxometry (1)
- NONOate (1)
- Negative Feedback Trading (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Numerical linear algebra (1)
- Organic light-emitting diode display (1)
- PIV (1)
- PROFINET (1)
- Parasitäre Strategie (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Requirements prioritization (1)
- Requirements relations (1)
- SLM (1)
- ScaLAPACK (1)
- Schienbeinschoner (1)
- Selektives Laser Schmelzen (1)
- Silber (1)
- Snow (1)
- Spleen (1)
- Stenotrophomonas maltophilia (1)
- Sterilisation process (1)
- Surgical staplers (1)
- Tool support (1)
- Trading Behavior (1)
- Uracil-phosphoribosyltransferase (1)
- VOF (1)
- Variable height stapler design (1)
- Velocity (1)
- Volume status (1)
- Wireless Networks (1)
- brachytherapy (1)
- dam-break (1)
- drag force (1)
- eigensolvers (1)
- incontinence (1)
- next generation network (1)
- numerical model (1)
- performance analysis (1)
- physical model (1)
- product bundling (1)
- prostate cancer (1)
- prostatectomy (1)
- quality of life (1)
- telecommunication (1)
Der Deutsche Bundestag und Bundesrat haben am 2.3.2012 bzw. 30.3.2012 das Gesetz gegen Kostenfallen im Internet verabschiedet, das am 1.8.2012 in Kraft treten wird. Hiermit hat der deutsche Gesetzgeber einen ersten Schritt getan, um die neue EU-Verbraucherrechterichtlinie vom 25.10.2011 (2011/83/EU, ABl L 304/64) in nationales Recht umzusetzen. Mit dieser Umsetzung ist das drängendste Problem der Kosten- und Abo-Fallen im elektronischen Geschäftsverkehr aus dem Gesamtpaket der Verbraucherrechterichtlinie herausgelöst und in dem neugefassten § 312g BGB behandelt worden. Eile bei der Umsetzung war hier geboten, weil unseriöse Unternehmen im elektronischen Rechtsverkehr zunehmend und in großem Umfang gegenüber ihren Kunden durch irreführende Gestaltungen ihrer Internetseiten verschleiern, dass die angebotenen Leistungen entgeltpflichtig sind.
The esophageal Doppler monitor (EDM) is a minimally-invasive hemodynamic device which evaluates both cardiac output (CO), and fluid status, by estimating stroke volume (SV) and calculating heart rate (HR). The measurement of these parameters is based upon a continuous and accurate approximation of distal thoracic aortic blood flow. Furthermore, the peak velocity (PV) and mean acceleration (MA), of aortic blood flow at this anatomic location, are also determined by the EDM. The purpose of this preliminary report is to examine additional clinical hemodynamic calculations of: compliance (C), kinetic energy (KE), force (F), and afterload (TSVRi). These data were derived using both velocity-based measurements, provided by the EDM, as well as other contemporaneous physiologic parameters. Data were obtained from anesthetized patients undergoing surgery or who were in a critical care unit. A graphical inspection of these measurements is presented and discussed with respect to each patient’s clinical situation. When normalized to each of their initial values, F and KE both consistently demonstrated more discriminative power than either PV or MA. The EDM offers additional applications for hemodynamic monitoring. Further research regarding the accuracy, utility, and limitations of these parameters is therefore indicated.
Mit Gesetz vom 29.7.2009 (BGBl 2009 I S. 2355) hat der deutsche Gesetzgeber die EU-Verbraucherkreditrichtlinie 2008/48/EG vom 23.4.2008 NWB PAAAD-28762 in nationales Recht umgesetzt. In diesem Gesetz ist auch der Immobiliardarlehensvertrag neu geregelt worden. Auf diese besondere Kreditform sind grds. die Vorschriften zum Verbraucherkredit anzuwenden, so dass der Darlehensgeber auch im Fall einer Immobilienfinanzierung zu vorvertraglicher Information des Verbrauchers verpflichtet ist. Beim finanzierten Immobilienerwerb werden Veräußerer und kreditgebende Bank häufig in Abstimmung und Zusammenarbeit tätig, so dass für die Bank besondere Aufklärungspflichten gegenüber dem Verbraucher entstehen. Im Fall der Verletzung dieser Pflichten drohen ihr Schadensersatzansprüche oder ein Widerrufsrecht des Verbrauchers.
Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry
(2012)
A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(%, v/v) in a H2O2 concentration range of 0%, v/v to 8%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes.
In vitro studies of the degradation kinetic of biopolymers are essential for the design and optimization of implantable biomedical devices. In the presented work, a field-effect capacitive sensor has been applied for the real-time and in situ monitoring of degradation processes of biopolymers for the first time. The polymer-covered field-effect sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. The feasibility of this approach has been experimentally proven by using the commercially available biomedical polymer poly(D,L-lactic acid) (PDLLA) as a model system. PDLLA films of different thicknesses were deposited on the Ta₂O₅-gate surface of the field-effect structure from a polymer solution by means of spin-coating method. The polymer-modified field-effect sensors have been characterized by means of capacitance–voltage and impedance-spectroscopy method. The degradation of the PDLLA was accelerated by changing the degradation medium from neutral (pH 7.2) to alkaline (pH 9) condition, resulting in drastic changes in the capacitance and impedance spectra of the polymer-modified field-effect sensor.
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current–voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.
Purpose: It was demonstrated previously that retinal pulse wave velocity (rPWV) as a measure of retinal arterial stiffness is increased in aged anamnestically healthy volunteers compared with young healthy subjects. Using novel methodology of rPWV assessment this finding was confirmed and investigated whether it might relate to the increased blood pressure usually accompanying the aging process, rather than to the aging itself.
Methods: A total of 12 young 25.5-year-old (24.0–28.8) [median(1st quartile–3rd quartile)] and 12 senior 68.5-year-old (63.8–71.8) anamnestically healthy volunteers; and 12 senior 63.0-year-old (60.8–65.0) validated healthy volunteers and 12 young 33.0-year-old (29.5–35.0) hypertensive patients were examined. Time-dependent alterations of vessel diameter were assessed by the Dynamic Vessel Analyzer in a retinal artery of each subject. The data were filtered and processed using mathematical signal analysis and rPWVs were calculated.
Results: rPWV amounted to 1200 (990-1470) RU (relative units)/s in the hypertensive group and to 1040 (700-2230) RU/s in anamnestically healthy seniors. These differed significantly from rPWVs in young healthy group (410 [280–500] RU/s) and in validated healthy seniors (400 [320–510] RU/s). rPWV associated with age and mean arterial pressure (MAP) in the pooled cohort excluded validated healthy seniors. In a regression model these associations remain when alternately adjusted for MAP and age. When including validated healthy seniors in the pooled cohort only association with MAP remains.
Conclusions: Both aging (with not excluded cardiovascular risk factors) and mild hypertension are associated with elevated rPWV. rPWV increases to a similar extent both in young mildly hypertensive subjects and in aged anamnestically healthy persons. Healthy aging is not associated with increased rPWV.
Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs
(2012)
The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines.
The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge.