Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1941)
- Fachbereich Elektrotechnik und Informationstechnik (1156)
- Fachbereich Wirtschaftswissenschaften (1124)
- Fachbereich Energietechnik (1068)
- Fachbereich Chemie und Biotechnologie (900)
- Fachbereich Maschinenbau und Mechatronik (818)
- Fachbereich Luft- und Raumfahrttechnik (772)
- Fachbereich Bauingenieurwesen (665)
- IfB - Institut für Bioengineering (630)
- INB - Institut für Nano- und Biotechnologien (586)
Has Fulltext
- no (9363) (remove)
Language
Document Type
- Article (5513)
- Conference Proceeding (1454)
- Book (1064)
- Part of a Book (574)
- Patent (177)
- Bachelor Thesis (170)
- Conference: Meeting Abstract (83)
- Report (83)
- Doctoral Thesis (82)
- Other (67)
- Contribution to a Periodical (20)
- Master's Thesis (18)
- Review (18)
- Working Paper (13)
- Conference Poster (5)
- Habilitation (5)
- Preprint (5)
- Talk (5)
- Diploma Thesis (3)
- Part of a Periodical (2)
- Examination Thesis (1)
- Video (1)
Keywords
- Illustration (10)
- Nachhaltigkeit (10)
- Corporate Design (9)
- Erscheinungsbild (8)
- Gamification (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Deutschland (6)
- Digitalisierung (6)
Design, evaluation and comparison of endorectal coils for hybrid MR-PET imaging of the prostate
(2020)
Prostate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexible and can move into different positions under external conditions, it is important to localise the focused region-of-interest using both MRI and PET under identical circumstances. In this work, we designed five commonly used linear and quadrature radiofrequency surface coils suitable for hybrid MR-PET use in endorectal applications. Due to the endorectal design and the shielded PET insert, the outer face of the coils investigated was curved and the region to be imaged was outside the volume of the coil. The tilting angles of the coils were varied with respect to the main magnetic field direction. This was done to approximate the various positions from which the prostate could be imaged. The transmit efficiencies and safety excitation efficiencies from simulations, together with the signal-to-noise ratios from the MR images were calculated and analysed. Overall, it was found that the overlapped loops driven in quadrature were superior to the other types of coils we tested. In order to determine the effect of the different coil designs on PET, transmission scans were carried out, and it was observed that the differences between attenuation maps with and without the coils were negligible. The findings of this work can provide useful guidance for the integration of such coil designs into MR-PET hybrid systems in the future.
Large scale central receiver systems typically deploy between thousands to more than a hundred thousand heliostats. During solar operation, each heliostat is aligned individually in such a way that the overall surface normal bisects the angle between the sun’s position and the aim point coordinate on the receiver. Due to various tracking error sources, achieving accurate alignment ≤1 mrad for all the heliostats with respect to the aim points on the receiver without a calibration system can be regarded as unrealistic. Therefore, a calibration system is necessary not only to improve the aiming accuracy for achieving desired flux distributions but also to reduce or eliminate spillage. An overview of current larger-scale central receiver systems (CRS), tracking error sources and the basic requirements of an ideal calibration system is presented. Leading up to the main topic, a description of general and specific terms on the topics heliostat calibration and tracking control clarifies the terminology used in this work. Various figures illustrate the signal flows along various typical components as well as the corresponding monitoring or measuring devices that indicate or measure along the signal (or effect) chain. The numerous calibration systems are described in detail and classified in groups. Two tables allow the juxtaposition of the calibration methods for a better comparison. In an assessment, the advantages and disadvantages of individual calibration methods are presented.
The application of atomic layer deposition in the production of sorbents for ⁹⁹Mo/⁹⁹ᵐTc generator
(2020)
New production routes for ⁹⁹Mo are steadily gaining importance. However, the obtained specific activity is much lower than currently produced by the fission of U-235. To be able to supply hospitals with ⁹⁹Mo/⁹⁹ᵐTc generators with the desired activity, the adsorption capacity of the column material should be increased. In this paper we have investigated whether the gas phase coating technique Atomic Layer Deposition (ALD), which can deposit ultra-thin layers on high surface area materials, can be used to attain materials with high adsorption capacity for ⁹⁹Mo. For this purpose, ALD was applied on a silica-core sorbent material to coat it with a thin layer of alumina. This sorbent material shows to have a maximum adsorption capacity of 120 mg/g and has a ⁹⁹ᵐTc elution efficiency of 55 ± 2% based on 3 executive elutions.
Extracellular acidification is a basic indicator for alterations in two vital metabolic pathways: glycolysis and cellular respiration. Measuring these alterations by monitoring extracellular acidification using cell-based biosensors such as LAPS plays an important role in studying these pathways whose disorders are associated with numerous diseases including cancer. However, the surface of the biosensors must be specially tailored to ensure high cell compatibility so that cells can represent more in vivo-like behavior, which is critical to gain more realistic in vitro results from the analyses, e.g., drug discovery experiments. In this work, O2 plasma patterning on the LAPS surface is studied to enhance surface features of the sensor chip, e.g., wettability and biofunctionality. The surface treated with O2 plasma for 30 s exhibits enhanced cytocompatibility for adherent CHO–K1 cells, which promotes cell spreading and proliferation. The plasma-modified LAPS chip is then integrated into a microfluidic system, which provides two identical channels to facilitate differential measurements of the extracellular acidification of CHO–K1 cells. To the best of our knowledge, it is the first time that extracellular acidification within microfluidic channels is quantitatively visualized as differential (bio-)chemical images.
Die fortschreitende Digitalisierung und Globalisierung fordert von den Unternehmen eine erhöhte Flexibilität und Anpassungsfähigkeit. Um dies zu erreichen, sind qualifizierte und engagierte Mitarbeiter/-innen unabdingbar. Gamification bietet die Möglichkeit, Beschäftigte individuell in ihren Tätigkeiten zu unterstützen und mittels Feedbackmechanismen zu motivieren. In dieser Arbeit wird ein Gamification Konzept bestehend aus einem intelligenten Arbeitsplatz, einer Wissensdatenbank und einer Gamification Plattform vorgestellt, welches an bestehende Produktionsumgebungen adaptiert werden kann. Das Konzept wird am Beispiel der Longboardproduktion in der Industrie 4.0 Modellfabrik der FH Aachen implementiert und evaluiert.
Die Erfindung betrifft eine schwefelvernetzbare Kautschukmischung, deren Vulkanisat und einen Fahrzeugreifen. Die schwefelvernetzbare Kautschukmischung enthält wenigstens die folgenden Bestandteile: - wenigstens einen Dienkautschuk; und - 10 bis 300 phr wenigstens einer Kieselsäure; und - 1 bis 30 phf wenigstens eines Silans A mit der allgemeinen Summenformel A-I) A-I)(R1)oSi-R2-(S-R3)q-S-X; und - 0,5 bis 30 phf wenigstens eines Silans B mit der allgemeinen Summenformel B-I) B-I) (R1)oSi-R2-(S-R3)u-S-R2-Si(R1)o wobei q =1, 2 oder 3 ist; und u = 1, 2 oder 3 ist; und X ein Wasserstoffatom oder eine –C(=O)-R8 Gruppe ist wobei R8 ausgewählt ist aus Wasserstoff, C1-C20 Alkylgruppen, vorzugsweise C1-C17, C6-C20- Arylgruppen, vorzugsweise Phenyl, C2-C20-Alkenylgruppen und C7-C20-Aralkylgruppen.
Die Erfindung betrifft eine schwefelvernetzbare Kautschukmischung, deren Vulkanisat und einen Fahrzeugreifen. Die erfindungsgemäße Kautschukmischung enthält wenigstens folgende Bestandteile: - Wenigstens einen Dienkautschuk; - wenigstens eine Kohle (HTC-Kohle), die mittels hydrothermaler Karbonisierung von wenigstens einer Ausgangssubstanz hergestellt ist. Der erfindungsgemäße Fahrzeugreifen weist in wenigstens einem Bauteil wenigstens ein erfindungsgemäßes Vulkanisat der Kautschukmischung auf.
Fahrzeugreifen
(2018)
Die Erfindung betrifft einen Fahrzeugreifen mit zumindest einem radial außen befindlichen Gummilaufstreifen, Wulstbereichen für den Anschluss an eine Felge und mit auf einer Gummimischung basierenden Seitenwandbereichen zwischen Gummilaufstreifen und den Wulstbereichen. Ferner betrifft die Erfindung Verfahren zur Herstellung solcher Fahrzeugreifen. Um den Anteil der umweltschädlichen Substanzen, insbesondere im Innenstadtbereich, zu reduzieren weisen die Seitenwandbereiche auf der äußeren Oberfläche eine für den oxidativen Abbau von Molekülen photokatalytisch aktive Substanz auf.
Die Erfindung betrifft eine schwefelvernetzbare Kautschukmischung, deren Vulkanisat und einen Fahrzeugreifen.Die schwefelvernetzbare Kautschukmischung enthält wenigstens die folgenden Bestandteile:- wenigstens einen Dienkautschuk; und- 10 bis 300 phr wenigstens einer Kieselsäure ; und- 1 bis 30 phf wenigstens eines Silans A mit der allgemeinen Summenformel A-I)und- 0,5 bis 30 phf wenigstens eines Silans B mit der allgemeinen Summenformel B-I)wobei u gleich 0, 1, 2 oder 3 und v gleich 0 oder 1 ist.
Die Erfindung betrifft ein Verfahren zum Bestimmen einer Sitzeinstellung (23) eines Sitzes (3) eines Kraftfahrzeugs (1), bei welchem folgende Schritte durchgeführt werden:- Bereitstellen einer Körperabmessung (12) eines Nutzers (6) des Kraftfahrzeugs (1);- Bereitstellen einer Sitzeigenschaft (13) des Sitzes (3) des Kraftfahrzeugs (1);- Bereitstellen eines mit zumindest einer Referenzsitzeigenschaft (20), zumindest einer Referenzkörperabmessung (21) und zumindest einer Referenzsitzeinstellung (22) trainiertes künstliches neuronales Netz (14); und- Bestimmen der Sitzeinstellung (23) durch Eingabe der Körperabmessung (12) und der Sitzeigenschaft (13) in das künstliche neuronale Netz (14).