Refine
Year of publication
- 2020 (227) (remove)
Document Type
- Article (124)
- Conference Proceeding (55)
- Part of a Book (16)
- Book (9)
- Review (7)
- Doctoral Thesis (3)
- Other (3)
- Patent (3)
- Administrative publication (3)
- Contribution to a Periodical (1)
- Part of Periodical (1)
- Poster (1)
- Report (1)
Language
- English (157)
- German (68)
- Multiple languages (1)
- nld (1)
Keywords
- Amtliche Mitteilung (3)
- MINLP (3)
- Additive manufacturing (2)
- Adjacent buildings (2)
- Experimental validation (2)
- Historical centres (2)
- INODIS (2)
- SIJ (2)
- Shake table test (2)
- Solar-Institut Jülich (2)
- Stone masonry (2)
- Verwaltungs- und Benutzungsordnung (2)
- 3D printing (1)
- Acceptance (1)
- Adaptive control (1)
- Anwendungsorientierter Forschungsansatz (1)
- Aufhebungsordnung (1)
- Biofuel (1)
- Biorefinery (1)
- Blind prediction competition (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (52)
- Fachbereich Energietechnik (34)
- IfB - Institut für Bioengineering (33)
- Fachbereich Luft- und Raumfahrttechnik (31)
- Fachbereich Wirtschaftswissenschaften (31)
- Fachbereich Elektrotechnik und Informationstechnik (29)
- ECSM European Center for Sustainable Mobility (17)
- Fachbereich Maschinenbau und Mechatronik (17)
- Fachbereich Bauingenieurwesen (14)
- Fachbereich Chemie und Biotechnologie (13)
- Solar-Institut Jülich (13)
- INB - Institut für Nano- und Biotechnologien (12)
- Institut fuer Angewandte Polymerchemie (7)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (6)
- Nowum-Energy (6)
- FH Aachen (4)
- IBB - Institut für Baustoffe und Baukonstruktionen (3)
- IaAM - Institut für angewandte Automation und Mechatronik (3)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- Fachbereich Architektur (1)
Trotz fortschreitender Automatisierung bleiben manuelle Tätigkeiten ein wichtiger Baustein der Fertigung kundenindividueller Produkte. Um die Mitarbeiter(innen) zu unterstützen und um eine effiziente Arbeit zu ermöglichen, werden zunehmend auf Augmented Reality (AR) basierende Systeme eingesetzt. Die vorgestellte Arbeit konzentriert sich auf die Entwicklung ganzheitlicher AR-Arbeitsplätze für den Einsatz in kleinen und mittleren Unternehmen (KMU). Das entwickelte AR- Handarbeitskonzept beinhaltet eine Just-in-time-Darstellung der Arbeitsaufgaben auf Werkstücken mit automatisierter Fertigungskontrolle. Als
Reaktion auf kurze Produktlebenszyklen und hohe Produktvielfalten sind alle Komponenten auf maximale Flexibilität ausgelegt. Ein Umrüsten auf neue Produkte kann innerhalb von Minuten erfolgen.
The adoption of the Digital Health Transformation is a tremendous paradigm change in health organizations, which is not a trivial process in reality. For that reason, in this chapter, it is proposed a methodology with the objective to generate a changing culture in healthcare organisations. Such a change culture is essential for the successful implementation of any supporting methods like Interactive Process Mining. It needs to incorporate (mostly) new ways of team-based and evidence-based approaches for solving structural problems in a digital healthcare environment.
Muscular activity in terms of surface electromyography (sEMG) is usually normalised to maximal voluntary isometric contractions (MVICs). This study aims to compare two different MVIC-modes in handcycling and examine the effect of moving average window-size. Twelve able-bodied male competitive triathletes performed ten MVICs against manual resistance and four sport-specific trials against fixed cranks. sEMG of ten muscles [M. trapezius (TD); M. pectoralis major (PM); M. deltoideus, Pars clavicularis (DA); M. deltoideus, Pars spinalis (DP); M. biceps brachii (BB); M. triceps brachii (TB); forearm flexors (FC); forearm extensors (EC); M. latissimus dorsi (LD) and M. rectus abdominis (RA)] was recorded and filtered using moving average window-sizes of 150, 200, 250 and 300 ms. Sport-specific MVICs were higher compared to manual resistance for TB, DA, DP and LD, whereas FC, TD, BB and RA demonstrated lower values. PM and EC demonstrated no significant difference between MVIC-modes. Moving average window-size had no effect on MVIC outcomes. MVIC-mode should be taken into account when normalised sEMG data are illustrated in handcycling. Sport-specific MVICs seem to be suitable for some muscles (TB, DA, DP and LD), but should be augmented by MVICs against manual/mechanical resistance for FC, TD, BB and RA.
Stored and cooled, highly-charged ions offer unprecedented capabilities for precision studies in the realm of atomic, nuclear structure and astrophysics[1]. After the successful investigation of the 96Ru(p,7)97Rh reaction cross section in 2009[2], the first measurement of the 124Xe(p,7)125Cs reaction cross section has been performed with decelerated, fully-ionized 124Xe ions in 2016 at the Experimental Storage Ring (ESR) of GSI[3]. Using a Double Sided Silicon Strip Detector, introduced directly into the ultra-high vacuum environment of a storage ring, the 125Cs proton-capture products have been successfully detected. The cross section has been measured at 5 different energies between 5.5AMeV and 8AMeV, on the high energy tail of the Gamow-window for hot, explosive scenarios such as supernovae and X-ray binaries. The elastic scattering on the H2 gas jet target is the major source of background to count the (p,7) events. Monte Carlo simulations show that an additional slit system in the ESR in combination with the energy information of the Si detector will enable background free measurements of the proton-capture products. The corresponding hardware is being prepared and will increase the sensitivity of the method tremendously.