Article
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1358) (remove)
Language
- English (1358) (remove)
Document Type
- Article (1358) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- CellDrum (3)
- Label-free detection (3)
- biosensors (3)
- hydrogen peroxide (3)
- impedance spectroscopy (3)
- shakedown analysis (3)
- Bacillus atrophaeus (2)
- Boundary integral equations (2)
- Capacitive field-effect sensor (2)
- Conductive boundary condition (2)
- Einspielanalyse (2)
- Empirical process (2)
- Field-effect sensor (2)
- Goodness-of-fit test (2)
- Independence test (2)
- Light-addressable potentiometric sensor (2)
- Lipopolysaccharide (2)
- Paired sample (2)
- Parametric bootstrap (2)
- Raman spectroscopy (2)
- Shakedown analysis (2)
- Stiffness (2)
- Traglastanalyse (2)
- Transmission eigenvalues (2)
- capacitive field-effect sensors (2)
- carbonized rice husk (2)
- constructive alignment (2)
- damage (2)
- examination (2)
- field-effect sensor (2)
- frequency mixing magnetic detection (2)
- likelihood ratio test (2)
- limit analysis (2)
- locomotion (2)
- long-term retention (2)
- multimodal (2)
- muscle fascicle behavior (2)
- not identically distributed (2)
- practical learning (2)
- shakedown (2)
- tobacco mosaic virus (TMV) (2)
- ultrasound (2)
- ultrasound imaging (2)
- (Bio)degradation (1)
- Acceleration (1)
- Achilles tendon (1)
- Adaptive control (1)
- Afterload (1)
- Ageing (1)
- Air purification (1)
- AlterG (1)
- Alternating plasticity (1)
- Alzheimer's disease (1)
- Analysis (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Architectural design (1)
- Architectural gear ratio (1)
- Assistive technology (1)
- Asymptotic efficiency (1)
- Autolysis (1)
- Automatic control (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Bacillus atrophaeus spores (1)
- Bacillus sp (1)
- Bacterial cellulose (1)
- Balance (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bauingenieurwesen (1)
- Bicharakteristikenverfahren (1)
- Bioabsorbable (1)
- Biocomposites (1)
- Biomechanical simulation (1)
- Bioreaktor (1)
- Biosolubilization (1)
- Blutzellenlagerung (1)
- Bone quality and biomechanics (1)
- Booster Station (1)
- Bootstrap (1)
- Bootstrapping (1)
- Boundary integral equations, (1)
- Brownian Pillow (1)
- CAD (1)
- CNOT (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect (1)
- Capacitive model (1)
- Carbon sources (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Categorial variable (1)
- Cell permeability (1)
- Cellular force (1)
- Cellulose nanostructure (1)
- Cement infiltration (1)
- Cementoblast (1)
- Censored data (1)
- Chemical images (1)
- Chemical imaging sensor (1)
- Chemical sensor (1)
- Circular Dichroism (1)
- Clusterion (1)
- Co-managed care (1)
- Coal (1)
- Collective risk model (1)
- Competitiveness (1)
- Complex System (1)
- Complex-valued eigenvalues (1)
- Compliance (1)
- Compression (1)
- Computational biomechanics (1)
- Concomitant (1)
- Conductive Boundary Condition (1)
- Conservation laws (1)
- Constitutive model (1)
- Contractile tension (1)
- Contractility (1)
- Convex optimization (1)
- Cost-effectiveness (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- Cramér-von-Mises test (1)
- Cross border adjustment mechanism (1)
- Crámer–von-Mises distance (1)
- Culture media (1)
- C–V method (1)
- DNA biosensor (1)
- DNA hybridization (1)
- DPA (dipicolinic acid) (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Deformation (1)
- Dehydrogenase (1)
- Design-by-analysis (1)
- Diaphorase (1)
- Dimensional splitting (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Discrete Optimization (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- Druckgeräte (1)
- Drug simulation (1)
- E-Mobility (1)
- E. coli detection (1)
- EIS capacitive sensor (1)
- ELISA (1)
- ES-FEM (1)
- Eigenvalue trajectories (1)
- Einspiel-Analyse (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elderly (1)
- Electrolyte–insulator–semiconductor (1)
- Electromagnetism (1)
- Electromechanical modeling (1)
- Elemental (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Energy-intensive industry (1)
- Enterprise information systems (1)
- Entropy solution (1)
- Environmental impact (1)
- Enzymatic biosensor (1)
- Enzyme coverage (1)
- Enzyme logic gate (1)
- Enzyme-linked immunosorbent assay (1)
- Epithel (1)
- Equivalence test (1)
- Esophageal Doppler monitor (1)
- Experiment (1)
- Exponential Euler scheme, (1)
- Exponential time differencing (1)
- External knee adduction moments (1)
- FS-FEM (1)
- Fall prevention (1)
- Fault approximation (1)
- Fault detection (1)
- Fehlerstellen (1)
- Fibroblast (1)
- Field effect (1)
- Field-effect biosensor (1)
- Finite difference methods (1)
- Finite element analysis (1)
- Finite element modelling (1)
- Fließgrenze (1)
- Floor prices (1)
- Force (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Frequency mixing magnetic detection (1)
- Functional Delta Method (1)
- Gamma distribution (1)
- Geriatric (1)
- German (1)
- Glaucoma (1)
- Global and local collapse (1)
- Gold nanoparticles (1)
- Goodness-of-fit tests for uniformity (1)
- Grenzwertberechnung (1)
- Ground-level falls (1)
- H2 (1)
- Hadamard differentiability (1)
- Haemodialysis (1)
- Handbike (1)
- Harnleiter (1)
- Heart tissue culture (1)
- Helmholtz equation (1)
- Hemoglobin structure (1)
- Heterostructure (1)
- Higher-order codes (1)
- Hip fractures (1)
- Hodgkin–Huxley models (1)
- Hoeffding-Blum-Kiefer-Rosenblatt independence test (1)
- Homogenization (1)
- Hotelling’s T² test (1)
- Human-Computer interaction (1)
- Hydrogen peroxide (1)
- Hydrogenotrophic methanogens (1)
- Hämoglobin (1)
- Hämoglobinstruktur (1)
- Image Reconstruction (1)
- Impedance spectroscopy (1)
- Implicit methods (1)
- Incomplete data (1)
- Induced pluripotent stem cells (1)
- Information extraction (1)
- Inotropic compounds (1)
- Integrated empirical distribution (survival) function (1)
- Interior Neumann eigenvalues (1)
- Interior transmission eigenvalues (1)
- Interior transmission problem (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse Scattering (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Inverse scattering (1)
- Inverse scattering problem (1)
- Inverse spectral problem (1)
- Ion channels (1)
- Iterative learning control (1)
- Kinetic energy (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- Kohlenstofffaser (1)
- LPS (1)
- Lab-on-Chip (1)
- Langevin theory (1)
- Layer-by-layer adsorption (1)
- LbL films (1)
- Light-addressable Potentiometric Sensor (1)
- Limit analysis (1)
- Liver (1)
- Long COVID (1)
- Luftreiniger (1)
- MCDA (1)
- MOS (1)
- Machine learning (1)
- Magnetic nanoparticles (1)
- Manipulated variables (1)
- Marginal homogeneity test (1)
- Master stamp (1)
- Materialermüdung (1)
- Matrix exponential (1)
- Mechanotransduction (1)
- Medusomyces gisevi (1)
- Metascintillator (1)
- Methane (1)
- Methanogenesis (1)
- Microcirculation (1)
- Micromagnetic simulation (1)
- Mild cognitive impairment (1)
- Mobility (1)
- Mobility tests (1)
- Mobility transition (1)
- Model-driven software engineering (1)
- Monotone methods (1)
- Multi-criteria decision analysis (1)
- Multi-dimensional partial differential equations (1)
- Multi-sample problem (1)
- Multianalyte detection (1)
- Multicell (1)
- Multiple TOF kernels (1)
- Multiplexing (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NONOate (1)
- Natural fibres (1)
- Negative impedance convertor (1)
- Neural Network (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Non-parallel fissures (1)
- Nonequilibrium dynamics (1)
- Nonlinear Dynamics (1)
- Nonlinear PDEs (1)
- Nonlinear eigenvalue problems (1)
- Nucleus Pulposus (1)
- Numerical inversion of Laplace transforms (1)
- Numerical linear algebra (1)
- Numerics (1)
- O2 plasma (1)
- Ocular blood flow (1)
- Organic light-emitting diode display (1)
- Organkultur (1)
- Osteoporose (1)
- Osteoporosis (1)
- Parabolic SPDEs (1)
- Paralympic sport (1)
- Penicillin (1)
- Permeability (1)
- Permeabilität (1)
- Peroxidase (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Pflanzenstress (1)
- Pharmacology (1)
- Photolithographic mimics (1)
- Physiology (1)
- Plant virus (1)
- Plasmacluster ion technology (1)
- Plastizität (1)
- Poly(allylamine hydrochloride) (1)
- Poly(d,l-lacticacid) (1)
- Polyimide (1)
- Polylactide acid (1)
- Polymer-matrix composites (1)
- Post-COVID-19 syndrome (1)
- Potential theory (1)
- Preference assessment (1)
- Pressure loaded crack-face (1)
- Prevention (1)
- Product-integration (1)
- Progressive plastic deformation (1)
- Prophylaxis (1)
- Proximal humerus fracture (1)
- Pulsations (1)
- Pump System (1)
- Quartz crystal microbalance (1)
- RVA (1)
- Ratchetting (1)
- Raumluft (1)
- Reaction-diffusion systems (1)
- Real distinct pole (1)
- Real-time monitoring (1)
- Recombinant activated protein C (1)
- Red blood cell storage (1)
- Regionalization (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Resampling test (1)
- Resistive temperature detector (1)
- Resolvent Operator (1)
- Resonance-mode measurement (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Robotic rehabilitation (1)
- Rohr (1)
- Rohrbruch (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- ScaLAPACK (1)
- Schwammknochen (1)
- Semi-parametric random censorship model (1)
- Septic cardiomyopathy (1)
- Shakedown (1)
- Shakedown criterion (1)
- Silk fibroin (1)
- Simulation (1)
- Simultaneous determination (1)
- Skeletal muscle (1)
- Small Aral Sea (1)
- Sn₃O₄ (1)
- Software and systems modeling (1)
- Source term (1)
- Spleen (1)
- Stahl (1)
- Steel industry (1)
- Sterilisation process (1)
- Stress concentrations (1)
- Strukturanalyse (1)
- Surface imprinted polymer (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Survival analysis (1)
- TMV adsorption (1)
- TOF PET (1)
- Ta₂O₅ gate (1)
- Technical Operations Research (TOR) (1)
- Temperaturabhängigkeit (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tendons (1)
- Tension (1)
- Tinetti test (1)
- Tissue Engineering (1)
- Tobacco mosaic virus (TMV) (1)
- Traglast (1)
- Transmission Eigenvalues (1)
- Ultrasound (1)
- Uniaxial compression test (1)
- Vapnik–Čhervonenkis class (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Velocity (1)
- Vertebroplastie (1)
- Vertebroplasty (1)
- Viscous flow (1)
- Viskose Strömung (1)
- Viskosität (1)
- Visual field asymmetry (1)
- Volterra integral equation (1)
- Volume of confidence regions (1)
- Volume status (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Wundheilung (1)
- XOR (1)
- Zeta potential (1)
- Zug-Druck Belastung (1)
- acetoin (1)
- acetoin reductase (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- alcoholic beverages (1)
- allocation (1)
- alternierend Verformbarkeit (1)
- amperometric biosensors (1)
- anaesthetic complications (1)
- anisotropy (1)
- annealing (1)
- aortic perfusion (1)
- aquaculture (1)
- aromatic amines (1)
- artificial olfactory image (1)
- asymptotic relative efficiency (1)
- atomic layer deposition (1)
- barium strontium titanate (1)
- biaxial tensile experiment (1)
- bicharacteristics (1)
- bioburdens (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- biomechanics (1)
- biopotential electrodes (1)
- biosensor (1)
- bone density (1)
- bone structure (1)
- bootstrap (1)
- burst pressure (1)
- burst tests (1)
- calorimetric gas sensor (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- cancellous bone (1)
- capacitive electrolyte–insulator–semiconductor sensors (1)
- capacitive field-effect sensor (1)
- carbon electrodes (1)
- cardiomyocyte biomechanics (1)
- catalytic metal (1)
- cell aerosolization (1)
- cell atomization (1)
- central symmetry test (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- chemical sensor (1)
- chip-based sensor setup (1)
- civil engineering (1)
- cognitive impairment (1)
- community dwelling (1)
- complete block symmetry (1)
- computational fluid dynamics analysis (1)
- conditional excess distribution (1)
- conditional expectation principle (1)
- confidence interval (1)
- connective tissue (1)
- constitutive modeling (1)
- contactless conductivity sensor (1)
- correlation (1)
- coupled Néel–Brownian relaxation dynamics (1)
- covariance principle (1)
- dental trauma (1)
- dialysis (1)
- difficult airway (1)
- direct method (1)
- distorted element (1)
- double-lumen tube intubation (1)
- drop jump (1)
- ecological structure (1)
- eigensolvers (1)
- elastic scattering (1)
- elastic solids (1)
- electrical conductivity of liquids (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- electromyography (1)
- electronic nose (1)
- encapsulation materials (1)
- endoluminal (1)
- endospores (1)
- energy absorption (1)
- energy dissipation (1)
- enzymatic (bio)degradation (1)
- enzymatic biosensor (1)
- enzyme cascade (1)
- epithelization (1)
- exchangeability test (1)
- extracorporeal membrane oxygenation (1)
- fatigue analyses (1)
- fibroin (1)
- field-effect structure (1)
- flaw (1)
- force generation (1)
- forecast (1)
- forehead EEG (1)
- fortschreitende plastische Deformation (1)
- frequency mixing (1)
- functional data (1)
- gait (1)
- gas sensor (1)
- glucose (1)
- glucose oxidase (GOx) (1)
- goodness-of-fit test (1)
- graphene oxide (1)
- healthy aging (1)
- heavy metals (1)
- hiPS cardiomyocytes (1)
- high-intensity exercise (1)
- high-k material (1)
- horseradish peroxidase (HRP) (1)
- huge dimensional data (1)
- human dermal fibroblasts (1)
- humic acid (1)
- hydroxylation (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- immobilization (1)
- in-ear EEG (1)
- in-situ monitoring (1)
- independence test (1)
- intraclass correlation coefficient (1)
- key performance indicators (1)
- konvexe Optimierung (1)
- lable-free detection (1)
- large language models (1)
- layer-by-layer technique (1)
- light-addressable potentiometric sensor (1)
- light-addressing technologies (1)
- lignite (1)
- limit load (1)
- lipopolysaccharide (1)
- lipopolysaccharides (1)
- load limit (1)
- magnetic actuation (1)
- magnetic beads (1)
- magnetic biosensing (1)
- magnetic nanoparticles (1)
- magnetic relaxation (1)
- magnetic sandwich immunoassay (1)
- magnetic sensing (1)
- magnetic separation (1)
- magnetic tweezers (1)
- magnetophoretic velocity (1)
- mechanical buffer (1)
- metagenomics (1)
- metal-oxide-semiconductor structure (1)
- method of fundamental solutions (1)
- microbial diversity (1)
- microfluidics (1)
- micromagnetic simulation (1)
- multi-functional material (1)
- multinomial distribution (1)
- multiparametric immunoassays (1)
- multivariate normal distribution (1)
- muscle mechanics (1)
- nanobelts (1)
- nanomaterials (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- naphtols (1)
- non-simplex S-FEM elements (1)
- novel photoexcitation method (1)
- optical sensor setup (1)
- optical spore trapping (1)
- optical trapping (1)
- organosilanes (1)
- overload (1)
- pH sensors (1)
- parabolic flight (1)
- penicillin (1)
- penicillinase (1)
- performance analysis (1)
- performance testing (1)
- phenols (1)
- photoelectrochemistry (1)
- physiology (1)
- pipes (1)
- plant scanner (1)
- plant stress (1)
- plant virus detection (1)
- plug-based microfluidic device (1)
- poly(d, l-lactic acid) (1)
- polyaniline (1)
- portfolio risk (1)
- prevention (1)
- psychosocial (1)
- random effects (1)
- random effects meta-regression model (1)
- ratchetting (1)
- rehabilitation (1)
- reliability analysis (1)
- reliability of structures (1)
- retinal microvasculature (1)
- retinal vessels (1)
- running (1)
- sEMG (1)
- sarcomere operating length (1)
- scanned light pulse technique (1)
- semantic role labeling (1)
- separable Hilbert space (1)
- series elastic element behavior (1)
- shakedown analyses (1)
- shotgun sequencing (1)
- shoulder (1)
- silanization (1)
- simulation (1)
- smooth muscle contraction (1)
- spatial resolution (1)
- speaker attribution (1)
- sprint start (1)
- standard error of measurement (1)
- sterilisation (1)
- sterility tests (1)
- sterilization (1)
- sterilization conditions (1)
- sterilization efficacy (1)
- sterilization methods (1)
- stiffness (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- superparamagnetic bead (1)
- superparamagnetic nanoparticles (1)
- surface functionalization (1)
- surface modification (1)
- survival (1)
- temperature (1)
- tendon rupture (1)
- tension–torsion loading (1)
- test-retest reliability (1)
- thermal ratcheting (1)
- thermometry (1)
- tilted constant illumination (1)
- titanium dioxide photoanode (1)
- tri-lineage differentiation (1)
- turnip vein clearing virus (TVCV) (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- ultrathin gate insulators (1)
- uniformly most powerful invariant test (1)
- unloading (1)
- validation methods (1)
- vessels (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- visualization (1)
- walking (1)
- walking gait (1)
- wound healing (1)
- yield stress (1)
Weak Representation of the Cumulative Hazard Function under Semiparametric Random Censorship Models
(2001)
There is a growing body of evidence for the effects of vitamin D on intestinal host-microbiome interactions related to gut dysbiosis and bowel inflammation. This brief review highlights the potential links between vitamin D and gut health, emphasizing the role of vitamin D in microbiological and immunological mechanisms of inflammatory bowel diseases. A comprehensive literature search was carried out in PubMed and Google Scholar using combinations of keywords “vitamin D,” “intestines,” “gut microflora,” “bowel inflammation”. Only articles published in English and related to the study topic are included in the review. We discuss how vitamin D (a) modulates intestinal microbiome function, (b) controls antimicrobial peptide expression, and (c) has a protective effect on epithelial barriers in the gut mucosa. Vitamin D and its nuclear receptor (VDR) regulate intestinal barrier integrity, and control innate and adaptive immunity in the gut. Metabolites from the gut microbiota may also regulate expression of VDR, while vitamin D may influence the gut microbiota and exert anti-inflammatory and immune-modulating effects. The underlying mechanism of vitamin D in the pathogenesis of bowel diseases is not fully understood, but maintaining an optimal vitamin D status appears to be beneficial for gut health. Future studies will shed light on the molecular mechanisms through which vitamin D and VDR interactions affect intestinal mucosal immunity, pathogen invasion, symbiont colonization, and antimicrobial peptide expression.
The chemical imaging sensor is a field-effect sensor which is able to visualize both the distribution of ions (in LAPS mode) and the distribution of impedance (in SPIM mode) inthe sample. In this study, a novel wound-healing assay is proposed, in which the chemical imaging sensor operated in SPIM mode is applied to monitor the defect of a cell layer brought into proximity of the sensing surface.A reduced impedance inside the defect, which was artificially formed ina cell layer, was successfully visualized in a photocurrent image.
In: Advanced Engineering Informatics. Vol 21, Issue 1, 2007, Pages 67-83 http://dx.doi.org/10.1016/j.aei.2006.10.001 eds. J.C. Kunz, I.F.C. Smith and T. Tomiyama, Elsevier, Seite 1-22 Current CAD tools are not able to support the conceptual design phase, and none of them provides a consistency analysis for sketches produced by architects. This phase is fundamental and crucial for the whole design and construction process of a building. To give architects a better support, we developed a CAD tool for conceptual design and a knowledge specification tool. The knowledge is specific to one class of buildings and it can be reused. Based on a dynamic and domain-specific knowledge ontology, different types of design rules formalize this knowledge in a graph-based form. An expressive visual language provides a user-friendly, human readable representation. Finally, a consistency analysis tool enables conceptual designs to be checked against this formal conceptual knowledge. In this article, we concentrate on the knowledge specification part. For that, we introduce the concepts and usage of a novel visual language and describe its semantics. To demonstrate the usability of our approach, two graph-based visual tools for knowledge specification and conceptual design are explained.
Virgin passive colon biomechanics and a literature review of active contraction constitutive models
(2022)
The objective of this paper is to present our findings on the biomechanical aspects of the virgin passive anisotropic hyperelasticity of the porcine colon based on equibiaxial tensile experiments. Firstly, the characterization of the intestine tissues is discussed for a nearly incompressible hyperelastic fiber-reinforced Holzapfel–Gasser–Ogden constitutive model in virgin passive loading conditions. The stability of the evaluated material parameters is checked for the polyconvexity of the adopted strain energy function using positive eigenvalue constraints of the Hessian matrix with MATLAB. The constitutive material description of the intestine with two collagen fibers in the submucosal and muscular layer each has been implemented in the FORTRAN platform of the commercial finite element software LS-DYNA, and two equibiaxial tensile simulations are presented to validate the results with the optical strain images obtained from the experiments. Furthermore, this paper also reviews the existing models of the active smooth muscle cells, but these models have not been computationally studied here. The review part shows that the constitutive models originally developed for the active contraction of skeletal muscle based on Hill’s three-element model, Murphy’s four-state cross-bridge chemical kinetic model and Huxley’s sliding-filament hypothesis, which are mainly used for arteries, are appropriate for numerical contraction numerical analysis of the large intestine.
Impaired cerebral autoregulation and neurovascular coupling (NVC) contribute to delayed cerebral ischemia after subarachnoid hemorrhage (SAH). Retinal vessel analysis (RVA) allows non-invasive assessment of vessel dimension and NVC hereby demonstrating a predictive value in the context of various neurovascular diseases. Using RVA as a translational approach, we aimed to assess the retinal vessels in patients with SAH. RVA was performed prospectively in 24 patients with acute SAH (group A: day 5–14), in 11 patients 3 months after ictus (group B: day 90 ± 35), and in 35 age-matched healthy controls (group C). Data was acquired using a Retinal Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and NVC using flicker-light excitation. Diameter of retinal vessels—central retinal arteriolar and venular equivalent—was significantly reduced in the acute phase (p < 0.001) with gradual improvement in group B (p < 0.05). Arterial NVC of group A was significantly impaired with diminished dilatation (p < 0.001) and reduced area under the curve (p < 0.01) when compared to group C. Group B showed persistent prolonged latency of arterial dilation (p < 0.05). Venous NVC was significantly delayed after SAH compared to group C (A p < 0.001; B p < 0.05). To our knowledge, this is the first clinical study to document retinal vasoconstriction and impairment of NVC in patients with SAH. Using non-invasive RVA as a translational approach, characteristic patterns of compromise were detected for the arterial and venous compartment of the neurovascular unit in a time-dependent fashion. Recruitment will continue to facilitate a correlation analysis with clinical course and outcome.
The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry.
Validation of a novel method for detecting and stabilizing malfunctioning areas in fuel cell stacks
(2014)
In this paper a setup for detecting malfunctioning areas of MEAs in fuel cell stacks is described. Malfunctioning areas generate electric cross currents inside bipolar plates. To exploit this we suggest bipolar plates consisting not of two but of three layers. The third one is a highly conducting layer and segmented such that the cross currents move along the segments to the surface of the stack where they can be measured by an inductive sensor. With this information a realistic model can be used to detect the malfunctioning area. Furthermore the third layer will prevent any current inhomogeneity of a malfunctioning cell to spread to neighbouring cells in the stack. In this work the results of measurements in a realistic cell setup will be compared with the results obtained in simulation studies with the same configuration. The basis for the comparison is the reliable characterisation of the electrical properties of the cell components and the implication of these results into the simulation model. The experimental studies will also show the limits in the maximum number of segments, which can be used for a reliable detection of cross currents.
Using a cell-based gas biosensor for investigation of adverse effects of acetone vapors in vitro
(2013)
The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed.
On the model of musculocutaneous wound in rats, the effect of applicative sorption by carbonized rise shell (CRS) on the healing of festering wound was studied. It has been shown, that cytological changes end with rapid scar formation. The use of CRS at the period of severe purulent wound contributes to its favorable course, prevents the development of complications of the animals from sepsis.
The demand of replacements for inoperable organs exceeds the amount of available organ transplants. Therefore, tissue engineering developed as a multidisciplinary field of research for autologous in-vitro organs. Such three dimensional tissue constructs request the application of a bioreactor. The UREPLACE bioreactor is used to grow cells on tubular collagen scaffolds OPTIMAIX Sponge 1 with a maximal length of 7 cm, in order to culture in vitro an adequate ureter replacement. With a rotating unit, (urothelial) cells can be placed homogeneously on the inner scaffold surface. Furthermore, a stimulation is combined with this bioreactor resulting in an orientation of muscle cells. These culturing methods request a precise control of several parameters and actuators. A combination of a LabBox and the suitable software LabVision is used to set and conduct parameters like rotation angles, velocities, pressures and other important cell culture values. The bioreactor was tested waterproof successfully. Furthermore, the temperature controlling was adjusted to 37 °C and the CO2 - concentration regulated to 5 %. Additionally, the pH step responses of several substances showed a perfect functioning of the designed flow chamber. All used software was tested and remained stable for several days.
We investigate interaction networks that we derive from multivariate time series with methods frequently employed in diverse scientific fields such as biology, quantitative finance, physics, earth and climate sciences, and the neurosciences. Mimicking experimental situations, we generate time series with finite length and varying frequency content but from independent stochastic processes. Using the correlation coefficient and the maximum cross-correlation, we estimate interdependencies between these time series. With clustering coefficient and average shortest path length, we observe unweighted interaction networks, derived via thresholding the values of interdependence, to possess non-trivial topologies as compared to Erdös-Rényi networks, which would indicate small-world characteristics. These topologies reflect the mostly unavoidable finiteness of the data, which limits the reliability of typically used estimators of signal interdependence. We propose random networks that are tailored to the way interaction networks are derived from empirical data. Through an exemplary investigation of multichannel electroencephalographic recordings of epileptic seizures – known for their complex spatial and temporal dynamics – we show that such random networks help to distinguish network properties of interdependence structures related to seizure dynamics from those spuriously induced by the applied methods of analysis.
Unitary Operator
(2009)
Transport through Redox-Active Ru-Terpyridine Complexes Integrated in Single Nanoparticle Devices
(2020)
Transition metal complexes are electrofunctional molecules due to their high conductivity and their intrinsic switching ability involving a metal-to-ligand charge transfer. Here, a method is presented to contact reliably a few to single redox-active Ru-terpyridine complexes in a CMOS compatible nanodevice and preserve their electrical functionality. Using hybrid materials from 14 nm gold nanoparticles (AuNP) and bis-{4′-[4-(mercaptophenyl)-2,2′:6′,2″-terpyridine]}-ruthenium(II) complexes a device size of 30² nm² inclusive nanoelectrodes is achieved. Moreover, this method bears the opportunity for further downscaling. The Ru-complex AuNP devices show symmetric and asymmetric current versus voltage curves with a hysteretic characteristic in two well separated conductance ranges. By theoretical approximations based on the single-channel Landauer model, the charge transport through the formed double-barrier tunnel junction is thoroughly analyzed and its sensibility to the molecule/metal contact is revealed. It can be verified that tunneling transport through the HOMO is the main transport mechanism while decoherent hopping transport is present to a minor extent.
In this work, the bioabsorbable materials, namely fibroin, polylactide acid (PLA), magnesium and magnesium oxide are investigated for their application as transient, resistive temperature detectors (RTD). For this purpose, a thin-film magnesium-based meander-like electrode is deposited onto a flexible, bioabsorbable substrate (fibroin or PLA) and encapsulated (passivated) by additional magnesium oxide layers on top and below the magnesium-based electrode. The morphology of different layered RTDs is analyzed by scanning electron microscopy. The sensor performance and lifetime of the RTD is characterized both under ambient atmospheric conditions between 30°C and 43°C, and wet tissue-like conditions with a constant temperature regime of 37°C. The latter triggers the degradation process of the magnesium-based layers. The 3-layers RTDs on a PLA substrate could achieve a lifetime of 8.5 h. These sensors also show the best sensor performance under ambient atmospheric conditions with a mean sensitivity of 0.48 Ω/°C ± 0.01 Ω/°C.
Training-induced increase in Achilles tendon stiffness affects tendon strain pattern during running
(2019)
Background
During the stance phase of running, the elasticity of the Achilles tendon enables the utilisation of elastic energy and allows beneficial contractile conditions for the triceps surae muscles. However, the effect of changes in tendon mechanical properties induced by chronic loading is still poorly understood. We tested the hypothesis that a training-induced increase in Achilles tendon stiffness would result in reduced tendon strain during the stance phase of running, which would reduce fascicle strains in the triceps surae muscles, particularly in the mono-articular soleus.
Methods
Eleven subjects were assigned to a training group performing isometric singleleg plantarflexion contractions three times per week for ten weeks, and another ten subjects formed a control group. Before and after the training period, Achilles tendon stiffness was estimated, and muscle-tendon mechanics were assessed during running at preferred speed using ultrasonography, kinematics and kinetics.
Results
Achilles tendon stiffness increased by 18% (P <0:01) in the training group, but the associated reduction in strain seen during isometric contractions was not statistically significant. Tendon elongation during the stance phase of running was similar after training, but tendon recoil was reduced by 30% (P <0:01), while estimated tendon force remained unchanged. Neither gastrocnemius medialis nor soleus fascicle shortening during stance was affected by training.
Discussion
These results show that a training-induced increase in Achilles tendon
stiffness altered tendon behaviour during running. Despite training-induced changes in tendon mechanical properties and recoil behaviour, the data suggest that fascicle shortening patterns were preserved for the running speed that we examined. The asymmetrical changes in tendon strain patterns supports the notion that simple inseries models do not fully explain the mechanical output of the muscle-tendon unit during a complex task like running.
Trace metal determination by dc resistance changes of microstructured thin gold film electrodes
(1999)
An amperometric biosensor using a substrate recycling principle was realized for the detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and Ringer’s solution at pH 6.5 and pH 7.4, respectively. In proof-of-concept experiments, a Boolean logic-gate principle has been applied to develop a digital adrenaline biosensor based on an enzyme AND logic gate. The obtained results demonstrate that the developed digital biosensor is capable for a rapid qualitative determination of the presence/absence of adrenaline in a YES/NO statement. Such digital biosensor could be used in clinical diagnostics for the control of a correct insertion of a catheter in the adrenal veins during adrenal venous-sampling procedure.
The LAPS (light-addressable potentiometric sensor) platform is one of the most attractive approaches for chemical and biological sensing with many applications ranging from pH and ion/analyte concentration measurements up to cell metabolism detection and chemical imaging. However, although it is generally accepted that LAPS measurements are spatially resolved, the light-addressability feature of LAPS devices has not been discussed in detail so far. In this work, an extended electrical equivalent-circuit model of the LAPS has been presented, which takes into account possible cross-talk effects due to the capacitive coupling of the non-illuminated region. A shunting effect of the non-illuminated area on the measured photocurrent and addressability of LAPS devices has been studied. It has been shown, that the measured photocurrent will be determined not only by the local interfacial potential in the illuminated region but also by possible interfacial potential changes in the non-illuminated region, yielding cross-talk effects. These findings were supported by the experimental investigations of a penicillin-sensitive multi-spot LAPS and a metal-insulator-semiconductor LAPS as model systems.
A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.
Sterilisation processes are compulsory in medicine, pharmacy, and food industries to prevent infections of consumers and microbiological contaminations of products. Monitoring the sterilisation by conventional microbiological methods is time- and lab-consuming. To overcome this problem, in this work a novel biosensor has been proposed. The sensor enables a fast method to evaluate sterilisation processes. By means of thin-film technology the sensor's transducer structures in form of IDEs (interdigitated electrodes) have been fabricated on a silicon substrate. Physical characterisation of the developed sensor was done by AFM, SEM, and profilometry. Impedance analyses were conducted for the electrical characterisation. As microbiological layer spores of B. atrophaeus have been immobilised on the sensing structure; spores of this type are a well-known sterilisation test organism. Impedance measurements at a fixed frequency over time were performed to monitor the immobilisation process. A sterilisation process according to aseptic filling machines was applied to demonstrate the sensor functionality. After both, immobilisation and sterilisation, a change in impedance could successfully be detected.
Monitoring of organic acids (OA) and volatile fatty acids (VFA) is crucial for the control of anaerobic digestion. In case of unstable process conditions, an accumulation of these intermediates occurs. In the present work, two different enzyme-based biosensor arrays are combined and presented for facile electrochemical determination of several process-relevant analytes. Each biosensor utilizes a platinum sensor chip (14 × 14 mm²) with five individual working electrodes. The OA biosensor enables simultaneous measurement of ethanol, formate, d- and l-lactate, based on a bi-enzymatic detection principle. The second VFA biosensor provides an amperometric platform for quantification of acetate and propionate, mediated by oxidation of hydrogen peroxide. The cross-sensitivity of both biosensors toward potential interferents, typically present in fermentation samples, was investigated. The potential for practical application in complex media was successfully demonstrated in spiked sludge samples collected from three different biogas plants. Thereby, the results obtained by both of the biosensors were in good agreement to the applied reference measurements by photometry and gas chromatography, respectively. The proposed hybrid biosensor system was also used for long-term monitoring of a lab-scale biogas reactor (0.01 m³) for a period of 2 months. In combination with typically monitored parameters, such as gas quality, pH and FOS/TAC (volatile organic acids/total anorganic carbonate), the amperometric measurements of OA and VFA concentration could enhance the understanding of ongoing fermentation processes.
The conjunction of (bio-)chemical recognition elements with nanoscale biological building blocks such as virus particles is considered as a very promising strategy for the creation of biohybrids opening novel opportunities for label-free biosensing. This work presents a new approach for the development of biosensors using tobacco mosaic virus (TMV) nanotubes or coat proteins (CPs) as enzyme nanocarriers. Sensor chips combining an array of Pt electrodes loaded with glucose oxidase (GOD)-modified TMV nanotubes or CP aggregates were used for amperometric detection of glucose as a model system for the first time. The presence of TMV nanotubes or CPs on the sensor surface allows binding of a high amount of precisely positioned enzymes without substantial loss of their activity, and may also ensure accessibility of their active centers for analyte molecules. Specific and efficient immobilization of streptavidin-conjugated GOD ([SA]-GOD) complexes on biotinylated TMV nanotubes or CPs was achieved via bioaffinity binding. These layouts were tested in parallel with glucose sensors with adsorptively immobilized [SA]-GOD, as well as [SA]-GOD crosslinked with glutardialdehyde, and came out to exhibit superior sensor performance. The achieved results underline a great potential of an integration of virus/biomolecule hybrids with electronic transducers for future applications in biosensorics and biochips.
The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented
Thin film chemical sensors based on chalcogenide glasses for „electronic tongue“ applications
(2001)
This study addresses a proof-of-concept experiment with a biocompatible screen-printed carbon electrode deposited onto a biocompatible and biodegradable substrate, which is made of fibroin, a protein derived from silk of the Bombyx mori silkworm. To demonstrate the sensor performance, the carbon electrode is functionalized as a glucose biosensor with the enzyme glucose oxidase and encapsulated with a silicone rubber to ensure biocompatibility of the contact wires. The carbon electrode is fabricated by means of thick-film technology including a curing step to solidify the carbon paste. The influence of the curing temperature and curing time on the electrode morphology is analyzed via scanning electron microscopy. The electrochemical characterization of the glucose biosensor is performed by amperometric/voltammetric measurements of different glucose concentrations in phosphate buffer. Herein, systematic studies at applied potentials from 500 to 1200 mV to the carbon working electrode (vs the Ag/AgCl reference electrode) allow to determine the optimal working potential. Additionally, the influence of the curing parameters on the glucose sensitivity is examined over a time period of up to 361 days. The sensor shows a negligible cross-sensitivity toward ascorbic acid, noradrenaline, and adrenaline. The developed biocompatible biosensor is highly promising for future in vivo and epidermal applications.
In this article, we present an overview on the thermocatalytic reaction of hydrogen peroxide (H₂O₂) gas on a manganese (IV) oxide (MnO₂) catalytic structure. The principle of operation and manufacturing techniques are introduced for a calorimetric H₂O₂ gas sensor based on porous MnO₂. Results from surface analyses by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) of the catalytic material provide indication of the H₂O₂ dissociation reaction schemes. The correlation between theory and the experiments is documented in numerical models of the catalytic reaction. The aim of the numerical models is to provide further information on the reaction kinetics and performance enhancement of the porous MnO₂ catalyst.
Thermodynamic stability, configurational motions and internal forces of haemoglobin (Hb) of three endotherms (platypus, Ornithorhynchus anatinus; domestic chicken, Gallus gallus domesticus and human, Homo sapiens) and an ectotherm (salt water crocodile, Crocodylus porosus) were investigated using circular dichroism, incoherent elastic neutron scattering and coarse-grained Brownian dynamics simulations. The experimental results from Hb solutions revealed a direct correlation between protein resilience, melting temperature and average body temperature of the different species on the 0.1 ns time scale. Molecular forces appeared to be adapted to permit conformational fluctuations with a root mean square displacement close to 1.2 Å at the corresponding average body temperature of the endotherms. Strong forces within crocodile Hb maintain the amplitudes of motion within a narrow limit over the entire temperature range in which the animal lives. In fully hydrated powder samples of human and chicken, Hb mean square displacements and effective force constants on the 1 ns time scale showed no differences over the whole temperature range from 10 to 300 K, in contrast to the solution case. A complementary result of the study, therefore, is that one hydration layer is not sufficient to activate all conformational fluctuations of Hb in the pico- to nanosecond time scale which might be relevant for biological function. Coarse-grained Brownian dynamics simulations permitted to explore residue-specific effects. They indicated that temperature sensing of human and chicken Hb occurs mainly at residues lining internal cavities in the β-subunits.
Therefore Fermat is right
(2014)
It was Fernat's idea to investigate how many numbers would fulfill the equation according to the Pythagorean Theorem if the exponent were increased to random, e.g. to a3 + b3 = c3. His question became therefore: are there two whole numbers the cubes of which add up to the volume of the cube of a third whole number? He posed this same question, of course, for all kinds of higher exponents, so that the equation could be generalized: is there an integral solution for the equation an + bn = cn, if the exponent n is higher than 2? Although in 1993, the English mathematician Andrew Wiles was able to produce an arithmetical proof for Fermat's famous theorem, I will show that there is a simple logical explanation which is also pragmatic and plausible and what is the result of a fundamental alternative idea how our world seems to be constructed.
The most of conventional methods of air purification use the power of a fan to draw in air and pass it through a filter. The problem of bacterial contamination of inner parts of such a type of air conditioners in some cases draws attention towards alternative air-cleaning systems. Some manufacturers offer to use the ozone's bactericidal and deodorizing effects, but the wide spreading of such systems is restricted by the fact that toxic effects of ozone in respect of human beings are well known. In 2000 Sharp Inc. introduced "Plasma Cluster Ions (PCI)" air purification technology, which uses plasma discharge to generate cluster ions (I 0-14 ). This technology has been developed for those customers that are conscious about health and hygiene. In our experiments, we focused on some principal aspects of plasma-generated ions application - time-dependency and irreversibility of bactericidal action, spatial and kinetic characteristics of emitted cluster particles, their chemical targets in the microbial cells.
A network of brain areas is expected to be involved in supporting the motion aftereffect. The most active components of this network were determined by means of an fMRI study of nine subjects exposed to a visual stimulus of moving bars producing the effect. Across the subjects, common areas were identified during various stages of the effect, as well as networks of areas specific to a single stage. In addition to the well-known motion-sensitive area MT the prefrontal brain areas BA44 and 47 and the cingulate gyrus, as well as posterior sites such as BA37 and BA40, were important components during the period of the motion aftereffect experience. They appear to be involved in control circuitry for selecting which of a number of processing styles is appropriate. The experimental fMRI results of the activation levels and their time courses for the various areas are explored. Correlation analysis shows that there are effectively two separate and weakly coupled networks involved in the total process. Implications of the results for awareness of the effect itself are briefly considered in the final discussion.
The inverse scattering problem for a conductive boundary condition and transmission eigenvalues
(2018)
In this paper, we consider the inverse scattering problem associated with an inhomogeneous media with a conductive boundary. In particular, we are interested in two problems that arise from this inverse problem: the inverse conductivity problem and the corresponding interior transmission eigenvalue problem. The inverse conductivity problem is to recover the conductive boundary parameter from the measured scattering data. We prove that the measured scatted data uniquely determine the conductivity parameter as well as describe a direct algorithm to recover the conductivity. The interior transmission eigenvalue problem is an eigenvalue problem associated with the inverse scattering of such materials. We investigate the convergence of the eigenvalues as the conductivity parameter tends to zero as well as prove existence and discreteness for the case of an absorbing media. Lastly, several numerical and analytical results support the theory and we show that the inside–outside duality method can be used to reconstruct the interior conductive eigenvalues.
The hybrid K+/Ca2+ sensor based on laser scanned silicon transducer for multi-component analysis
(2002)
The hot spots conjecture is only known to be true for special geometries. This paper shows numerically that the hot spots conjecture can fail to be true for easy to construct bounded domains with one hole. The underlying eigenvalue problem for the Laplace equation with Neumann boundary condition is solved with boundary integral equations yielding a non-linear eigenvalue problem. Its discretization via the boundary element collocation method in combination with the algorithm by Beyn yields highly accurate results both for the first non-zero eigenvalue and its corresponding eigenfunction which is due to superconvergence. Additionally, it can be shown numerically that the ratio between the maximal/minimal value inside the domain and its maximal/minimal value on the boundary can be larger than 1 + 10− 3. Finally, numerical examples for easy to construct domains with up to five holes are provided which fail the hot spots conjecture as well.