Article
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1591)
- Fachbereich Wirtschaftswissenschaften (705)
- Fachbereich Elektrotechnik und Informationstechnik (638)
- Fachbereich Energietechnik (609)
- Fachbereich Chemie und Biotechnologie (602)
- INB - Institut für Nano- und Biotechnologien (542)
- Fachbereich Maschinenbau und Mechatronik (484)
- IfB - Institut für Bioengineering (449)
- Fachbereich Luft- und Raumfahrttechnik (379)
- Fachbereich Bauingenieurwesen (333)
- Solar-Institut Jülich (107)
- Fachbereich Architektur (79)
- Fachbereich Gestaltung (58)
- ECSM European Center for Sustainable Mobility (43)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (42)
- Nowum-Energy (36)
- Sonstiges (23)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (18)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (16)
- IBB - Institut für Baustoffe und Baukonstruktionen (10)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (3)
- IMP - Institut für Mikrowellen- und Plasmatechnik (3)
- Verwaltung (3)
- FH Aachen (2)
- Kommission für Forschung und Entwicklung (1)
- Kommission für Planung und Finanzen (1)
Language
Document Type
- Article (5644) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- Rapid Prototyping (4)
- biosensors (4)
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of specific ions on the sensing surface. The conventional chemical imaging system based on the light-addressable potentiometric sensor (LAPS), however, required a long time to obtain a chemical image, due to the slow mechanical scan of a single light beam. For high-speed imaging, a plurality of light beams modulated at different frequencies can be employed to measure the ion concentrations simultaneously at different locations on the sensor plate by frequency division multiplex (FDM). However, the conventional measurement geometry of back-side illumination limited the bandwidth of the modulation frequency required for FDM measurement, because of the low-pass filtering characteristics of carrier diffusion in the Si substrate. In this study, a high-speed chemical imaging system based on front-side-illuminated LAPS was developed, which achieved high-speed spatiotemporal recording of pH change at a rate of 70 frames per second.
Mass transfer correlation for evaporation–condensation thermal process in the range of 70 °C–95 °C
(2013)
Latente Steuern im Zusammenhang mit Beteiligungen an Tochterunternehmen im IFRS-Konzernabschluss
(2013)
Modeling contribution to risk assessment of thermal production power for geothermal reservoirs
(2013)
A High-Throughput Functional Complementation Assay for Classification of BRCA1 Missense Variants
(2013)
Obesity-induced overexpression of miR-802 impairs glucose metabolism through silencing of Hnf1b
(2013)
Size unlimited markerless deletions by a transconjugative plasmid-system in Bacillus licheniformis
(2013)
The concept of an injective affine embedding of the quantum states into a set of classical states, i.e., into the set of the probability measures on some measurable space, as well as its relation to statistically complete observables is revisited, and its limitation in view of a classical reformulation of the statistical scheme of quantum mechanics is discussed. In particular, on the basis of a theorem concerning a non-denseness property of a set of coexistent effects, it is shown that an injective classical embedding of the quantum states cannot be supplemented by an at least approximate classical description of the quantum mechanical effects. As an alternative approach, the concept of quasi-probability representations of quantum mechanics is considered.
In modernen Fahrzeugkarosserien der Großserie kommen zunehmend Materialmischbauweisen
zur Anwendung. In Zusammenarbeit der Daimler AG, der Tower Automotive Holding
GmbH, der Imperia GmbH sowie der Partnerunternehmen KSM Castings GmbH und Schaufler
Tooling GmbH & Co. KG wird das Leichtbaupotenzial von Stahlblech-AluminiumverbundgussHybriden
am Beispiel des vorderen Dachquerträgers des Mercedes-Benz Viano/Vito ausführlich
untersucht.
In modernen Fahrzeugkarosserien der Großserie kommen zunehmend Materialmischbauweisen zur Anwendung. In Zusammenarbeit der Daimler AG, der Tower Automotive Holding GmbH, der Imperia GmbH sowie der Partnerunternehmen KSM Castings GmbH und Schaufler Tooling GmbH & Co. KG wird das Leichtbaupotenzial von Aluminiumverbundguss-Stahlblech-Hybriden am Beispiel des vorderen Dachquerträgers des Mercedes-Benz Viano/Vito ausführlich untersucht.
Der Telekommunikationsmarkt erfährt substanzielle Veränderungen. Neue Geschäftsmodelle, innovative Dienstleistungen und Technologien erfordern Reengineering, Transformation und Prozessstandardisierung. Mit der Enhanced Telecom Operation Map (eTOM) bietet das TM Forum ein international anerkanntes de facto Referenz-Prozess-Framework basierend auf spezifischen Anforderungen und Ausprägungen der Telekommunikationsindustrie an. Allerdings enthält dieses Referenz-Framework nur eine hierarchische Sammlung von Prozessen auf unterschiedlichen Abstraktionsebenen. Eine Kontrollsicht verstanden als sequenzielle Anordnung von Aktivitäten und daraus resultierend ein realer Prozessablauf fehlt ebenso wie eine Ende-zu-Ende-Sicht auf den Kunden. In diesem Artikel erweitern wir das eTOM-Referenzmodell durch Referenzprozessabläufe, in welchen wir das Wissen über Prozesse in Telekommunikationsunternehmen abstrahieren und generalisieren. Durch die Referenzprozessabläufe werden Unternehmen bei dem strukturierten und transparenten (Re-)Design ihrer Prozesse unterstützt. Wir demonstrieren die Anwendbarkeit und Nützlichkeit unserer Referenzprozessabläufe in zwei Fallstudien und evaluieren diese anhand von Kriterien für die Bewertung von Referenzmodellen. Die Referenzprozessabläufe wurden vom TM Forum in den Standard aufgenommen und als Teil von eTOM Version 9 veröffentlicht. Darüber hinaus diskutieren wir die Komponenten unseres Ansatzes, die auch außerhalb der Telekommunikationsindustrie angewandt werden können.
The carbonized rice husk (CRH) was evaluated for its wound healing activity in rats using excision models. In this study, the influences of CRH on wound healing in rat skin in vivo and cellular behavior of human dermal fibroblasts in vitro were investigated. The obtained results showed that the CRH treatment promoted wound epithelization in rats and exhibited moderate inhibition of cell proliferation in vitro. CRH with lanolin oil treated wounds were found to epithelize faster as compared to controls.
The response of Bacillus licheniformis to heat and ethanol stress and the role of the SigB regulon
(2013)
Biotechnological downstream processing is usually an elaborate procedure, requiring a multitude of unit operations to isolate the target component. Besides the disadvantageous space-time yield, the risks of cross-contaminations and product loss grow fast with the complexity of the isolation procedure. A significant reduction of unit operations can be achieved by application of magnetic particles, especially if these are functionalized with affinity ligands. As magnetic susceptible materials are highly uncommon in biotechnological processes, target binding and selective separation of such particles from fermentation or reactions broths can be done in a single step. Since the magnetizable particles can be produced from iron salts and low priced polymers, a single-use implementation of these systems is highly conceivable. In this article, the principles of magnetizable particles, their synthesis and functionalization are explained. Furthermore, applications in the area of reaction engineering, microfluidics and downstream processing are discussed focusing on established single-use technologies and development potential.
Living cells are complex biological systems transforming metabolites taken up from the surrounding medium. Monitoring the responses of such cells to certain substrate concentrations is a challenging task and offers possibilities to gain insight into the vitality of a community influenced by the growth environment. Cell-based sensors represent a promising platform for monitoring the metabolic activity and thus, the “welfare” of relevant organisms. In the present study, metabolic responses of the model bacterium Escherichia coli in suspension, layered onto a capacitive field-effect structure, were examined to pulses of glucose in the concentration range between 0.05 and 2 mM. It was found that acidification of the surrounding medium takes place immediately after glucose addition and follows Michaelis–Menten kinetic behavior as a function of the glucose concentration. In future, the presented setup can, therefore, be used to study substrate specificities on the enzymatic level and may as well be used to perform investigations of more complex metabolic responses. Conclusions and perspectives highlighting this system are discussed.
Commercial materials with polyvinylpolypyrrolidone and polymeric amberlites (XAD7HP, XAD16) are commonly used for the adsorptive downstream processing of polyphenols from renewable resources. In this study, beta-zeolite-based adsorbent systems were examined, and their properties were compared to organic resins. Batch adsorption experiments were conducted with synthetic solutions of major polyphenols. Adsorption isotherms and desorption characteristics of individual adsorbent were determined based on these results. Maximum adsorption capacities were calculated using the Langmuir model. For example, the zeolites had capacities up to 203.2 mg/g for ferulic acid. To extend these results to a complex system, additional experiments were performed on rapeseed meal and wheat seed extracts as representative renewable resources. HPLC analysis showed that with 7.5% w/v, which is regarded as the optimum amount of zeolites, zeolites A and B could bind 100% of the major polyphenols as well as release polyphenols at high yields. Additionally, regeneration experiments were performed with isopropyl alcohol at 99°C to evaluate how zeolites regenerate under mild conditions. The results showed only a negligible loss of adsorption capacity and no loss of desorption capacity. In summary, it was concluded that beta-zeolites were promising adsorbents for developing new processes to isolate polyphenols from renewable resources.
Optical coherence tomography : a potential tool to predict premature rupture of fetal membranes
(2013)
Einschränkung von Taluskippung und -vorschub durch Sprunggelenkorthesen nach fibularer Bandruptur
(2013)
Die fibulare Bandruptur zählt zu einer der am häufigsten auftretenden Verletzungen des
Bewegungsapparats. In den meisten Fällen wird heute die konservativ frühfunktionelle Therapie mit Sprunggelenkorthesen allgemein bevorzugt. Im Rahmen der vorliegenden Studie wurden 14 verschiedene Sprunggelenkorthesen im Hinblick auf ihre Einschränkung von Taluskippung und Talusvorschub
untersucht. Zur Simulation einer fibularen Bandruptur wurde ein Unterschenkelmodell aus Holz mit Fußteil, mit angelegten Orthesen in einen Scheuba-Halteapparat eingespannt und mit 150 N seitlich sowie anterior-posterior belastet. Anhand der erstellten "gehaltenen" Röntgenaufnahmen konnten Taluskippung und Talusvorschub jeder einzelnen Orthese eindeutig bestimmt werden. Die meisten Orthesen erreichten zufriedenstellende Ergebnisse. Es stellte sich heraus, dass vor allem eine eng anliegende, im Gelenkbereich anatomisch angepasste Form vorteilhaft zu sein scheint.
Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers
(2013)
Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution.
Pepräsentatives Dösen
(2013)
Our world is well ordered in measurement and number : or why natural constants are as they are
(2013)
All the important natural constants can be logically explained with and derived from the first four ordinal numbers, 1, 2, 3 and 4, its addition to ten and finally the standard values for obviously maximal feasibility Ω and the optimum in our world, the Golden Section (GS), i.e. the number sequences 273 and 618. They both are the first three numbers of irrational results by an arithmetical transformation of simple geometrical relationships by creating multiplicity out of singularity. Both of them show that the infinite is inherent in finiteness and explain in a simple way the smallest deviations and fluctuations between the physical AS-IS state and the obvious spiritual ideal behind: Wherever we look in this world, and especially in important key-positions, we regularly find these sequences. All of the above mentioned numbers so seem to be key players in our world, what can be demonstrated by the derivation of natural constants.
Purpose
To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T.
Methods
The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study.
Results
Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly.
Conclusion
The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T.