Refine
Year of publication
- 2005 (130) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (40)
- Fachbereich Luft- und Raumfahrttechnik (27)
- IfB - Institut für Bioengineering (23)
- Fachbereich Energietechnik (19)
- Fachbereich Elektrotechnik und Informationstechnik (15)
- INB - Institut für Nano- und Biotechnologien (15)
- Fachbereich Chemie und Biotechnologie (10)
- Fachbereich Maschinenbau und Mechatronik (8)
- Fachbereich Wirtschaftswissenschaften (5)
- Freshman Institute (4)
Language
- English (130) (remove)
Document Type
- Article (99)
- Conference Proceeding (23)
- Book (5)
- Part of a Book (1)
- Lecture (1)
- Working Paper (1)
Keywords
- Bauingenieurwesen (2)
- CAD (2)
- civil engineering (2)
- Alternating plasticity (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Deformation (1)
- Design-by-analysis (1)
- Einspiel-Analyse (1)
- Einspiel-Kriterium (1)
- Einspielen <Werkstoff> (1)
- Energietechnik (1)
- Energy (1)
- Energy Systems (1)
- Evolutionary Neurocontrol (1)
- FEM (1)
- Finite-Elemente-Methode (1)
- Global and local collapse (1)
- Grenzwertberechnung (1)
- Kernenergie (1)
- Limit analysis (1)
- Low-Thrust Propulsion (1)
- Nuclear Applications (1)
- Plastizität (1)
- Pressure loaded crack-face (1)
- Progressive plastic deformation (1)
- Pyrometrie (1)
- Rapid Prototyping (1)
- Shakedown analysis (1)
- Shakedown criterion (1)
- Spacecraft Trajectory Optimization (1)
- Temperaturmessung (1)
- Traglastanalyse (1)
- Umwelt (1)
- acoustic pyrometry (1)
- alternierend Verformbarkeit (1)
- environment (1)
- flue gas components (1)
- fortschreitende plastische Deformation (1)
- steam production (1)
- temperature measurement (1)
This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.
The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner
(2005)
Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view.
Preliminary data shows a correct identification of the crystal layer about (98±1)%. Typically the energy resolution is (23.3±0.5)% for the luyap layer and (15.4±0.4)% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled.
The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it.
Das Drallrohr
(2005)
Flow visualization by means of PIV of an artificial aortic heart valve fixed into a mock aorta
(2005)
Solar Sail Trajectory Optimization for Intercepting, Impacting, and Deflecting Near-Earth Asteroids
(2005)
Solar Sails for Near- and Medium-Term Scientific Deep Space Missions / W. Sebolt ; B. Dachwald
(2005)
Multiple Near-Earth Asteroid Rendezvous and Sample Return Using First Generation Solar Sailcraft
(2005)
468 Scatter dose determination at the eye lens during a mask based whole brain radiotherapy (WBRT)
(2005)
Studieren lehren
(2005)
Miniaturised reference electrodes for field-effect sensors compatible to silicon chip technology
(2005)
Proc. of the 2005 ASCE Intl. Conf. on Computing in Civil Engineering (ICCC 2005) eds. L. Soibelman und F. Pena-Mora, Seite 1-14, ASCE (CD-ROM), Cancun, Mexico, 2005 Current CAD tools are not able to support the fundamental conceptual design phase, and none of them provides consistency analyses of sketches produced by architects. To give architects a greater support at the conceptual design phase, we develop a CAD tool for conceptual design and a knowledge specification tool allowing the definition of conceptually relevant knowledge. The knowledge is specific to one class of buildings and can be reused. Based on a dynamic knowledge model, different types of design rules formalize the knowledge in a graph-based realization. An expressive visual language provides a user-friendly, human readable representation. Finally, consistency analyses enable conceptual designs to be checked against this defined knowledge. In this paper we concentrate on the knowledge specification part of our project.
In: Computer Aided Architectural Design Futures 2005 2005, Part 4, 207-216, DOI: http://dx.doi.org/10.1007/1-4020-3698-1_19 The conceptual design at the beginning of the building construction process is essential for the success of a building project. Even if some CAD tools allow elaborating conceptual sketches, they rather focus on the shape of the building elements and not on their functionality. We introduce semantic roomobjects and roomlinks, by way of example to the CAD tool ArchiCAD. These extensions provide a basis for specifying the organisation and functionality of a building and free architects being forced to directly produce detailed constructive sketches. Furthermore, we introduce consistency analyses of the conceptual sketch, based on an ontology containing conceptual relevant knowledge, specific to one class of buildings.
One of the most important parameters in a burning chamber - in power stations, in waste to energy plants - is the temperature. This temperature is in the range of 700-1500 °C - one of the most advanced measuring methods being the acoustic pyrometry with the possibility of producing temperature mapping in one level of the burning chamber - comparable to computer tomography. The results of these measurements discussed in the presentation can be used - to fulfil the legal requirements in the FRG or in the EU - to equalise the temperature in one level of the burning chamber to optimise the steam production (better efficiency of the plant) and to minimise the production of temperature controlled flue gas components (NO, CO a. o.) - to control the SNCR-process if used.
The Ministry of Science and Research in North Rhine-Westphalia created eight platforms of excellence, one in the research area „Energy and Environment“ in 2002 at ACUAS. This platform concentrates the research and development of 13 professors in Jülich and Aachen and of two scientific institutes with different topics: – NOWUM-Energy with emphasis on efficient and economic energy conversion – The Solar Institute Jülich – SIJ – being the largest research institute in the field of renewables at a University of Applied Sciences in Germany With this platform each possible energy conversion – nuclear, fossil, renewable- can be dealt with to help solving the two most important problems of mankind, energy and potable water. At the CSE are presented the historical development, some research results and the combined master studies in „Energy Systems“ and „Nuclear Applications“
In the new European standard for unfired pressure vessels, EN 13445-3, there are two approaches for carrying out a Design-by-Analysis that cover both the stress categorization method (Annex C) and the direct route method (Annex B) for a check against global plastic deformation and against progressive plastic deformation. This paper presents the direct route in the language of limit and shakedown analysis. This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for mechanical and thermal actions. One observation from the examples is that the so-called 3f (3Sm) criterion fails to be a reliable check against progressive plastic deformation. Precise conditions are given, which greatly restrict the applicability of the 3f criterion.
Limit loads can be calculated with the finite element method (FEM) for any component, defect geometry, and loading. FEM suggests that published long crack limit formulae for axial defects under-estimate the burst pressure for internal surface defects in thick pipes while limit loads are not conservative for deep cracks and for pressure loaded crack-faces. Very deep cracks have a residual strength, which is modelled by a global collapse load. These observations are combined to derive new analytical local and global collapse loads. The global collapse loads are close to FEM limit analyses for all crack dimensions.
Rapid Prototyping Technology: Types of models, rapid prototyping processes, prototyper Fundamentals of rapid prototyping Industrial rapid prototyping technology: Stereolithography, (Selective) laser sintering ((S)LS), Layer laminate manufacturing (LLM), Fused layer modeling (FLM), Three dimensional printing (3DP)