Conference Proceeding
Refine
Year of publication
- 2006 (94) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (34)
- Fachbereich Bauingenieurwesen (15)
- Fachbereich Maschinenbau und Mechatronik (14)
- INB - Institut für Nano- und Biotechnologien (13)
- Fachbereich Energietechnik (10)
- Fachbereich Luft- und Raumfahrttechnik (9)
- Fachbereich Wirtschaftswissenschaften (5)
- Solar-Institut Jülich (4)
- IfB - Institut für Bioengineering (3)
- Nowum-Energy (2)
Document Type
- Conference Proceeding (94) (remove)
Keywords
- Biosensor (23)
- Bauingenieurwesen (2)
- Bauplanung (2)
- CAD (2)
- biosensor (2)
- civil engineering (2)
- 3-nitrofluoranthene (1)
- Aachen / Fachhochschule Aachen / Fachbereich Bauingenieurwesen (1)
- Absolvententreffen (1)
- Abwasser (1)
A concept for a sensitive micro total analysis system for high throughput fluorescence imaging
(2006)
This paper discusses possible methods for on-chip fluorescent imaging for integrated bio-sensors. The integration of optical and electro-optical accessories, according to suggested methods, can improve the performance of fluorescence imaging. It can boost the signal to background ratio by a few orders of magnitudes in comparison to conventional discrete setups. The methods that are present in this paper are oriented towards building reproducible arrays for high-throughput micro total analysis systems (µTAS). The first method relates to side illumination of the fluorescent material placed into microcompartments of the lab-on-chip. Its significance is in high utilization of excitation energy for low concentration of fluorescent material. The utilization of a transparent µLED chip, for the second method, allows the placement of the excitation light sources on the same optical axis with emission detector, such that the excitation and emission rays are directed controversly. The third method presents a spatial filtering of the excitation background.
A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polymer membrane was impregnated with tetra-ammine platinum chloride hydrate and the metal ions were subsequently reduced by using either sodium tetrahydroborate or potassium tetrahydroborate. The hydrogen sensing characteristics with air as reference gas is reported. The sensors were capable of detecting hydrogen concentrations from 10 ppm to 10% in nitrogen. The response time was in the range of 10-30 s and a stable linear current output was observed. The thin Pt films were characterized by XRD, Infrared Spectroscopy, Optical Microscopy, Atomic Force Microscopy, Scanning Electron Microscopy and EDAX.
Micromachined thermal heater platforms offer low electrical power consumption and high modulation speed, i.e. properties which are advantageous for realizing nondispersive infrared (NDIR) gas- and liquid monitoring systems. In this paper, we report on investigations on silicon-on-insulator (SOI) based infrared (IR) emitter devices heated by employing different kinds of metallic and semiconductor heater materials. Our results clearly reveal the superior high-temperature performance of semiconductor over metallic heater materials. Long-term stable emitter operation in the vicinity of 1300 K could be attained using heavily antimony-doped tin dioxide (SnO2:Sb) heater elements.
Study of swift heavy ion modified conduction polymer composites for application as gas sensor
(2006)
A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.
In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demonstrated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several additional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings.
Various planar technologies are employed for developing solid-state sensors having low cost, small size and high reproducibility; thin- and thick-film technologies are most suitable for such productions. Screen-printing is especially suitable due to its simplicity, low-cost, high reproducibility and efficiency in large-scale production. This technology enables the deposition of a thick layer and allows precise pattern control. Moreover, this is a highly economic technology, saving large amounts of the used inks. In the course of repetitions of the film-deposition procedure there is no waste of material due to additivity of this thick-film technology. Finally, the thick films can be easily and quickly deposited on inexpensive substrates. In this contribution, thick-film ion-selective electrodes based on ionophores as well as crystalline ion-selective materials dedicated for potentiometric measurements are demonstrated. Analytical parameters of these sensors are comparable with those reported for conventional potentiometric electrodes. All mentioned thick-film strip electrodes have been totally fabricated in only one, fully automated thickfilm technology, without any additional manual, chemical or electrochemical steps. In all cases simple, inexpensive, commercially available materials, i.e. flexible, plastic substrates and easily cured polymer-based pastes were used.
Analysis of error and time behavior of the IEEE 802.15.4 PHY-layer in an industrial environment
(2006)
Praktische Untersuchungen zum zeitlichen Übertragungs- und Bündelfehlerverhalten der IEEE 802.15.4
(2006)
We report on the synthesis and CO gas-sensing properties of mesoporous tin(IV) oxides (SnO2). For the synthesis cetyltrimethylammonium bromide (CTABr) was used as a structure-directing agent; the resulting SnO2 powders were applied as films to commercially available sensor substrates by drop coating. Nitrogen physisorption shows specific surface areas up to 160 m2·g-1 and mean pore diameters of about 4 nm, as verified by TEM. The film conductance was measured in dependence on the CO concentration in humid synthetic air at a constant temperature of 300 °C. The sensors show a high sensitivity at low CO concentrations and turn out to be largely insensitive towards changes in the relative humidity. We compare the materials with commercially available SnO2-based sensors.
O Perfil Reiss apresenta no resultado uma visão da estrutura dos motivos e impulsos de uma pessoa. O ponto de saída para a análise do resultado é o conhecimento de que os motivos vitais (= valores e metas de sobrevivência) formam a moldura, na qual as competências e capacidades que uma pessoa possui possam se desabrochar de forma ideal. A partir desse princípio, não existe no Perfil Reiss nenhum resultado que se possa classificar como correto ou falso, nem como bom ou mau. Uma comparação entre o resultado do Perfil Reiss e o conteúdo de uma atividade apresentada ou ambicionada dá informação sobre até que ponto a capacidade de rendimento de uma pessoa nessa posição pode vir ou virá a se desenvolver por um longo tempo.
"Mit dem "1. Erfahrungsaustausch" im Fachbereich Bauingenieurwesen berichten Absolventen des Fachbereichs aus der Praxis. Mit diesem Treffen wird die wichtige Verbindung zwischen Hochschule, ihren Absolventen und der Berufspraxis zum besonderen Anliegen gemacht und besonders gestärkt." Zitat Prof. Dr.- Ing. Hans Boegershausen, Dekan im Grußwort. Referenten und Themen: Wellmann, Judith: Perspektiven eines Bauingenieurs im konstruktiven Ingenieurbau Dirk Gobbele, Dirk: Planung der Umbaumaßnahme Hauptbahnhof Aachen Kretschmann, Lars: Planung und Bauleitung Buschtunnel Aachen Becker, Astrid: Anlagenmanagement und Aufgaben der DB Netz AG, Bauherrenvertretung und Wirtschaftlichkeit Plenz, Michael: Baurevision und Unternehmensberatung, Tätigkeit als öffentlich bestellter und vereidigter Sachverständiger Klöcker, Alexander: Das Leitungsbauunternehmen – Unternehmerische Strategie als Zukunftssicherung Türk, Roman: Sanierung von Hausanschlüssen Bornebusch, Michael: Hydraulische und Hydrologische Modellsimulationen als Planungswerkzeug für Hochwasser-Schutz-Maßnahmen Himmerich, Jörg : Pipeline Integrity Management System – Probabilistische Bewertung von Bauwerken am Beispiel von Hochdruckleitungen.