Refine
Year of publication
- 2024 (125)
- 2023 (194)
- 2022 (237)
- 2021 (230)
- 2020 (236)
- 2019 (309)
- 2018 (254)
- 2017 (258)
- 2016 (267)
- 2015 (284)
- 2014 (284)
- 2013 (286)
- 2012 (314)
- 2011 (311)
- 2010 (332)
- 2009 (341)
- 2008 (291)
- 2007 (271)
- 2006 (276)
- 2005 (263)
- 2004 (286)
- 2003 (218)
- 2002 (232)
- 2001 (210)
- 2000 (234)
- 1999 (232)
- 1998 (236)
- 1997 (214)
- 1996 (200)
- 1995 (192)
- 1994 (175)
- 1993 (155)
- 1992 (144)
- 1991 (100)
- 1990 (108)
- 1989 (110)
- 1988 (103)
- 1987 (105)
- 1986 (81)
- 1985 (83)
- 1984 (75)
- 1983 (70)
- 1982 (57)
- 1981 (54)
- 1980 (61)
- 1979 (58)
- 1978 (52)
- 1977 (32)
- 1976 (30)
- 1975 (28)
- 1974 (17)
- 1973 (12)
- 1972 (17)
- 1971 (11)
- 1970 (2)
- 1969 (2)
- 1968 (2)
- 1967 (1)
- 1963 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1941)
- Fachbereich Elektrotechnik und Informationstechnik (1156)
- Fachbereich Wirtschaftswissenschaften (1124)
- Fachbereich Energietechnik (1068)
- Fachbereich Chemie und Biotechnologie (900)
- Fachbereich Maschinenbau und Mechatronik (818)
- Fachbereich Luft- und Raumfahrttechnik (772)
- Fachbereich Bauingenieurwesen (665)
- IfB - Institut für Bioengineering (630)
- INB - Institut für Nano- und Biotechnologien (586)
Has Fulltext
- no (9363) (remove)
Language
Document Type
- Article (5513)
- Conference Proceeding (1454)
- Book (1064)
- Part of a Book (574)
- Patent (177)
- Bachelor Thesis (170)
- Conference: Meeting Abstract (83)
- Report (83)
- Doctoral Thesis (82)
- Other (67)
Keywords
- Illustration (10)
- Nachhaltigkeit (10)
- Corporate Design (9)
- Erscheinungsbild (8)
- Gamification (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Deutschland (6)
- Digitalisierung (6)
Solar sails enable missions to the outer solar system and beyond, although the solar
radiation pressure decreases with the square of solar distance. For such missions, the solar sail may gain a large amount of energy by first making one or more close approaches to the sun. Within this paper, optimal trajectories for solar sail missions to the outer planets and into near interstellar space (200 AU) are presented. Thereby, it is shown that even near/medium-term solar sails with relatively moderate performance allow reasonable transfer times to the boundaries of the solar system.
Recently, in his vision for space exploration, US president Bush announced to extend human presence across the solar system, starting with a human return to the Moon as early as 2015 in preparation for human exploration of Mars and other destinations. In Europe, an exploration program, termed AURORA, was established by ESA in 2001 – funded on a voluntary basis by ESA member states – with a clear focus on Mars and the ultimate goal of landing humans on Mars around 2030 in international cooperation. In 2003, a Human Spaceflight Vision Group was appointed by ESA with the task to develop a vision for the role of human spaceflight during the next quarter of the century. The resulting vision focused on a European-led lunar exploration initiative as part of a multi-decade, international effort to strengthen European identity and economy. After a review of the situation in Europe concerning space exploration, the paper outlines an approach for a consistent positioning of exploration within the existing European space programs, identifies destinations, and develops corresponding scenarios for an integrated strategy, starting with robotic missions to the Moon, Mars, and near-Earth asteroids. The interests of the European planetary in-situ science community, which recently met at DLR Cologne, are considered. Potential robotic lunar missions comprise polar landings to search for frozen volatiles and a sample return. For Mars, the implementation of a modest robotic landing mission in 2009 to demonstrate the capability for landing and prepare more ambitious and complex missions is discussed. For near-Earth asteroid exploration, a low-cost in-situ technology demonstration mission could yield important results. All proposed scenarios offer excellent science and could therefore create synergies between ESA’s mandatory and optional programs in the area of planetary science and exploration. The paper intents to stimulate the European discussion on space exploration and reflects the personal view of the authors.
Stahlbau
(2004)
Advanced on-wafer multiport calibration methods for mono- and mixed-mode device characterization
(2004)
TOP-Energy : softwaregestützte Analyse und Optimierung industrieller Energieversorgungssysteme
(2004)
Novel balanced inductor for compact differential systems / Sadeghfam, Arash; Heuermann, Holger
(2004)
A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes.
Planwirtschaft
(2004)
IT Service Level Agreements
(2004)
The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry.
This study has been performed to design the combination of the new ClearPET TM (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal Positron Emission Tomography (PET) system, with a microComputed Tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.
The ClearPET project
(2004)
The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view.
Rapid Prototyping
(2003)
Urkundenprozeß ohne Urkunden? Zur Zulässigkeit des Urkundenprozesses bei unstreitigem Vorbringen
(2003)
Anmerkung zu EuGH RS C-208/00 (Niederlassungsfreiheit und Internationales Gesellschaftsrecht)
(2003)
Rechtsfolgen vorbehaltloser Mietzahlung in Mangelkenntnis –Mehr als bloß eine Etappe beim BGH?
(2003)