Refine
Year of publication
- 2024 (13)
- 2023 (4)
- 2022 (10)
- 2021 (11)
- 2020 (14)
- 2019 (28)
- 2018 (16)
- 2017 (14)
- 2016 (35)
- 2015 (26)
- 2014 (11)
- 2013 (17)
- 2012 (30)
- 2011 (23)
- 2010 (23)
- 2009 (27)
- 2008 (21)
- 2007 (29)
- 2006 (39)
- 2005 (18)
- 2004 (20)
- 2003 (20)
- 2002 (8)
- 2001 (9)
- 2000 (17)
- 1999 (12)
- 1998 (13)
- 1997 (5)
- 1996 (14)
- 1995 (13)
- 1994 (9)
- 1993 (11)
- 1992 (11)
- 1991 (7)
- 1990 (4)
- 1989 (4)
- 1988 (10)
- 1987 (7)
- 1986 (5)
- 1985 (8)
- 1984 (8)
- 1983 (4)
- 1982 (3)
- 1981 (3)
- 1980 (5)
- 1979 (5)
- 1978 (3)
- 1977 (2)
- 1976 (2)
- 1975 (2)
- 1974 (2)
- 1972 (1)
- 1971 (1)
- 1969 (1)
Document Type
- Article (324)
- Book (117)
- Conference Proceeding (101)
- Part of a Book (86)
- Report (17)
- Doctoral Thesis (6)
- Contribution to a Periodical (2)
- Patent (2)
- Working Paper (2)
- Poster (1)
Has Fulltext
- no (658) (remove)
Keywords
- metal structure (4)
- steel (4)
- industrial research (3)
- iron and steel industry (3)
- materials technology (3)
- research report (3)
- Haustechnik (2)
- Heizung (2)
- Klimatechnik (2)
- Lüftung (2)
- Lüftungstechnik (2)
- Stickstoffoxide (2)
- building industry (2)
- building information modelling (2)
- building materials (2)
- energy efficiency (2)
- research project (2)
- resistance of materials (2)
- 20 fossil-fueled power plants (1)
- 3D printing (1)
Institute
- Fachbereich Bauingenieurwesen (658) (remove)
Die Eignung von Baggergut als mineralische Komponente in Deponie-Oberflächenabdichtungssystemen
(2003)
Sanierung des ehemaligen Gaswerkgeländes am Bremer Hauptbahnhof / K. Konertz ; E. Biener ; T. Sasse
(2003)
Schäden an Talsperren
(1984)
Koaxiale Stahlenergiepfähle
(2021)
Ein entscheidender Teil der Energiewende ist die Wärmewende im Gebäudesektor. Ein Schlüsselelement sind hier Wärmepumpen. Diese benötigen eine Wärmequelle, der sie Energie entziehen können, um sie auf ein höheres Temperaturniveau zu transformieren. Diese Wärmequelle kann bspw. das Erdreich sein, dessen Wärme durch Erdsonden erschlossen werden kann. In diesem Beitrag werden in Stahlpfähle integrierte Koaxialsonden mit dem Stand der Technik von Erdsonden gleichen Durchmessers bezüglich ihrer thermischen Leistungsmerkmale verglichen. Die Stahlenergiepfähle bieten neben der Wärmegewinnung weitere Vorteile, da sie auch eine statische Funktion übernehmen und rückstandsfrei zurückgebaut werden können. Es werden analytische und numerische Berechnungen vorgestellt, um die thermischen Potenziale beider Systeme zu vergleichen. Außerdem wird ein Testaufbau gezeigt, bei dem Stahlenergiepfähle in zwei verschiedenen Längen mit vorhandenen gängigen Erdsonden verglichen werden können. Die Berechnungen zeigen einen deutlichen thermischen Mehrertrag zwischen 26 % und 148 % der Stahlenergiepfähle gegenüber dem Stand der Technik abhängig vom Erdreich. Die Messergebnisse zeigen einen thermischen Mehrertrag von über 100 %. Es lässt sich also signifikante Erdsondenlänge einsparen. Dabei ist zu beachten, dass sich damit der thermisch genutzte Bereich des Erdreichs reduziert, wodurch die thermische Regeneration und/oder das Langzeitverhalten des Erdreichs an Bedeutung gewinnt.
Using optimization to design a renewable energy system has become a computationally demanding task as the high temporal fluctuations of demand and supply arise within the considered time series. The aggregation of typical operation periods has become a popular method to reduce effort. These operation periods are modelled independently and cannot interact in most cases. Consequently, seasonal storage is not reproducible. This inability can lead to a significant error, especially for energy systems with a high share of fluctuating renewable energy. The previous paper, “Time series aggregation for energy system design: Modeling seasonal storage”, has developed a seasonal storage model to address this issue. Simultaneously, the paper “Optimal design of multi-energy systems with seasonal storage” has developed a different approach. This paper aims to review these models and extend the first model. The extension is a mathematical reformulation to decrease the number of variables and constraints. Furthermore, it aims to reduce the calculation time while achieving the same results.
Optimierung des potentiellen Sauerstoffeintrags auf Treppenschussrinnen mit gemäßigter Neigung
(2009)
Sensitivity of phase detection techniques in aerated chute flows to hydraulic design parameters
(2012)
Hydraulic modeling is the classical approach to investigate and describe complex fluid motion. Many empirical formulas in the literature used for the hydraulic design of river training measures and structures have been developed using experimental data from the laboratory. Although computer capacities have increased to a high level which allows to run complex numerical simulations on standard workstation nowadays, non-standard design of structures may still raise the need to perform physical model investigations. These investigations deliver insight into details of flow patterns and the effect of varying boundary conditions. Data from hydraulic model tests may be used for calibration of numerical models as well. As the field of hydraulic modeling is very complex, this chapter intends to give a short overview on capacities and limits of hydraulic modeling in regard to river flows and hydraulic structures only. The reader shall get a first idea of modeling principles and basic considerations. More detailed information can be found in the references.
Optimization of the reaeration potential on embankment stepped spillways in skimming flow regime
(2008)
Application of the optical flow method to velocity determination in hydraulic structure models
(2016)
As with most high-velocity free-surface flows, stepped spillway flows become self-aerated when the drop height exceeds a critical value. Due to the step-induced macro-roughness, the flow field becomes more turbulent than on a similar smooth-invert chute. For this reason, cascades are oftentimes used as re-aeration structures in wastewater treatment. However, for stepped spillways as flood release structures downstream of deoxygenated reservoirs, gas transfer is also of crucial significance to meet ecological requirements. Prediction of mass transfer velocities becomes challenging, as the flow regime differs from typical previously studied flow conditions. In this paper, detailed air-water flow measurements are conducted on stepped spillway models with different geometry, with the aim to estimate the specific air-water interface. Re-aeration performances are determined by applying the absorption method. In contrast to earlier studies, the aerated water body is considered a continuous mixture up to a level where 75% air concentration is reached. Above this level, a homogenous surface wave field is considered, which is found to significantly affect the total air-water interface available for mass transfer. Geometrical characteristics of these surface waves are obtained from high-speed camera investigations. The results show that both the mean air concentration and the mean flow velocity have influence on the mass transfer. Finally, an empirical relationship for the mass transfer on stepped spillway models is proposed.
Optical flow estimation is known from Computer Vision where it is used to determine obstacle movements through a sequence of images following an assumption of brightness conservation. This paper presents the first study on application of the optical flow method to aerated stepped spillway flows. For this purpose, the flow is captured with a high-speed camera and illuminated with a synchronized LED light source. The flow velocities, obtained using a basic Horn–Schunck method for estimation of the optical flow coupled with an image pyramid multi-resolution approach for image filtering, compare well with data from intrusive conductivity probe measurements. Application of the Horn–Schunck method yields densely populated flow field data sets with velocity information for every pixel. It is found that the image pyramid approach has the most significant effect on the accuracy compared to other image processing techniques. However, the final results show some dependency on the pixel intensity distribution, with better accuracy found for grey values between 100 and 150.
Geologisch-geotechnischer Planungsprozess von Tunnelbauten mit Schwerpunkt tiefliegender Tunnel
(2014)
Deammonification for nitrogen removal in municipal wastewater in temperate and cold climate zones is currently limited to the side stream of municipal wastewater treatment plants (MWWTP). This study developed a conceptual model of a mainstream deammonification plant, designed for 30,000 P.E., considering possible solutions corresponding to the challenging mainstream conditions in Germany. In addition, the energy-saving potential, nitrogen elimination performance and construction-related costs of mainstream deammonification were compared to a conventional plant model, having a single-stage activated sludge process with upstream denitrification. The results revealed that an additional treatment step by combining chemical precipitation and ultra-fine screening is advantageous prior the mainstream deammonification. Hereby chemical oxygen demand (COD) can be reduced by 80% so that the COD:N ratio can be reduced from 12 to 2.5. Laboratory experiments testing mainstream conditions of temperature (8–20°C), pH (6–9) and COD:N ratio (1–6) showed an achievable volumetric nitrogen removal rate (VNRR) of at least 50 gN/(m3∙d) for various deammonifying sludges from side stream deammonification systems in the state of North Rhine-Westphalia, Germany, where m3 denotes reactor volume. Assuming a retained Norganic content of 0.0035 kgNorg./(P.E.∙d) from the daily loads of N at carbon removal stage and a VNRR of 50 gN/(m3∙d) under mainstream conditions, a resident-specific reactor volume of 0.115 m3/(P.E.) is required for mainstream deammonification. This is in the same order of magnitude as the conventional activated sludge process, i.e., 0.173 m3/(P.E.) for an MWWTP of size class of 4. The conventional plant model yielded a total specific electricity demand of 35 kWh/(P.E.∙a) for the operation of the whole MWWTP and an energy recovery potential of 15.8 kWh/(P.E.∙a) through anaerobic digestion. In contrast, the developed mainstream deammonification model plant would require only a 21.5 kWh/(P.E.∙a) energy demand and result in 24 kWh/(P.E.∙a) energy recovery potential, enabling the mainstream deammonification model plant to be self-sufficient. The retrofitting costs for the implementation of mainstream deammonification in existing conventional MWWTPs are nearly negligible as the existing units like activated sludge reactors, aerators and monitoring technology are reusable. However, the mainstream deammonification must meet the performance requirement of VNRR of about 50 gN/(m3∙d) in this case.
Gas- und Dampfturbinen-Kraftwerke mit Druckwirbelschicht- oder mit Druckvergasungsverfahren ermöglichen die Verstromung von Kohle mit hohem Wirkungsgrad und niedrigen Emissionen. Eine Voraussetzung für den Betrieb dieser Anlagen ist die Entstaubung der Rauchgase bei hohen Temperaturen und Drücken. Abreinigungsfilter mit keramischen Elementen werden dazu eingesetzt. Eine Reduzierung gasförmiger Schadstoffe unter den gleichen Bedingungen könnte Rauchgaswäsche ersetzen. Ziel des Gesamtvorhabens ist es, die Integration von Heißgasfiltration und katalytischem Abbau der Schadstoffe Kohlenmonoxid, Kohlenwasserstoffe und Stickoxide in einen Verfahrensschritt zu untersuchen. Die Arbeitsschwerpunkte dieses Teilvorhabens betreffen:
die katalytische Wirkung eisenhaltiger Braunkohlenaschen,
die Wirksamkeit des Calciumaluminat als Katalysator des Abbaus unverbrannter Kohlenwasserstoffe im Heißgasfilter,
numerische Simulation der kombinierten Abscheidung von Partikeln und gasförmigen Schadstoffen aus Rauchgasen
Im Rahmen von Forschungsvorhaben des BMBF und verschiedener Industriepartner betreibt der Lehrstuhl für Wärmeübertragung und Klimatechnik der RWTH Aachen Pilotanlagen und Prüfstände für Untersuchungen auf dem Gebiet der Heißgasfiltration mit keramischen Filterelementen. Als wesentlicher Garant für den Erfolg der Forschungsarbeit muß die auf das jeweilige Projekt genau abgestimmte Meß- und Regelungstechnik angesehen werden. Hierbei zählt neben der Auswahl geeigneter Hardwarekomponenten auch die Softwareentwicklung unter einer leistungsstarken und zuverlässigen Programmierumgebung. Anhand des Aufbaus dreier Versuchsanlagen im Technikumsmaßstab soll das Anforderungsprofil an die Meßtechnik bis hin zur Umsetzung innerhalb der Anlage skizziert werden. Der Heißgasfiltrationsprüfstand im Heizkraftwerk der RWTH Aachen dient der Beobachtung des Reinigungsverhaltens keramischer Filterelemente bei der Heißgasentstaubung im Temperaturbereich bis 850 Grad C. Wesentlich für die Meßwerterfassung ist hierbei die Kopplung eines Orion-Datenloggers der Firma Schlumberger mit LabView 4.0. Im Hochtemperaturofen des Lehrstuhls werden instationäre Druckmessungen an einer keramischen Filterkerze während eines Abreinigungsimpulses bei 950 Grad C mit hoher Samplingrate durchgeführt. Hierbei übernimmt eine durch LabView 4.0 angesteuerte E-Series Karte der Firma National Instruments die Signalaufnahme. Die katalytische Schadstoffreduktion und Entstaubung heißer Rauchgase bei 900 Grad C sind Ziele der Untersuchungen in einer erstellten Versuchsanlage mit einem Quarzglasreaktor. Die Signalerfassung und -konditionierung erfolgt über SCXI in Verbindung mit LabView 4.0, die Steuerung der Anlage übernehmen zwei Multifunktionskarten (National Instruments).