Conference Proceeding
Refine
Year of publication
- 2024 (14)
- 2023 (37)
- 2022 (48)
- 2021 (52)
- 2020 (55)
- 2019 (93)
- 2018 (74)
- 2017 (86)
- 2016 (72)
- 2015 (78)
- 2014 (55)
- 2013 (74)
- 2012 (81)
- 2011 (70)
- 2010 (94)
- 2009 (64)
- 2008 (48)
- 2007 (44)
- 2006 (54)
- 2005 (29)
- 2004 (25)
- 2003 (22)
- 2002 (25)
- 2001 (18)
- 2000 (14)
- 1999 (15)
- 1998 (21)
- 1997 (10)
- 1996 (7)
- 1995 (6)
- 1994 (4)
- 1993 (11)
- 1992 (6)
- 1991 (3)
- 1990 (2)
- 1989 (5)
- 1988 (3)
- 1987 (1)
- 1986 (2)
- 1985 (4)
- 1984 (3)
- 1983 (3)
- 1981 (2)
- 1980 (1)
- 1979 (1)
- 1978 (3)
- 1977 (2)
- 1975 (3)
- 1974 (1)
- 1973 (3)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (294)
- Fachbereich Energietechnik (230)
- Fachbereich Luft- und Raumfahrttechnik (203)
- Fachbereich Maschinenbau und Mechatronik (190)
- Solar-Institut Jülich (164)
- Fachbereich Medizintechnik und Technomathematik (161)
- IfB - Institut für Bioengineering (117)
- Fachbereich Bauingenieurwesen (103)
- ECSM European Center for Sustainable Mobility (62)
- Fachbereich Wirtschaftswissenschaften (55)
Has Fulltext
- no (1448) (remove)
Document Type
- Conference Proceeding (1448) (remove)
Keywords
- Enterprise Architecture (5)
- Gamification (5)
- Energy storage (4)
- Natural language processing (4)
- Power plants (4)
- hydrogen (4)
- solar sail (4)
- Associated liquids (3)
- Concentrated solar power (3)
- Hybrid energy system (3)
Clearance of blood components and fluid drainage play a crucial role in subarachnoid hemorrhage (SAH) and post hemorrhagic hydrocephalus (PHH). With the involvement of interstitial fluid (ISF) and cerebrospinal fluid (CSF), two pathways for the clearance of fluid and solutes in the brain are proposed. Starting at the level of capillaries, flow of ISF follows along the basement membranes in the walls of cerebral arteries out of the parenchyma to drain into the lymphatics and CSF [1]–[3]. Conversely, it is shown that CSF enters the parenchyma between glial and pial basement membranes of penetrating arteries [4]–[6]. Nevertheless, the involved structures and the contribution of either flow pathway to fluid balance between the subarachnoid space and interstitial space remains controversial. Low frequency oscillations in vascular tone are referred to as vasomotion and corresponding vasomotion waves are modeled as the driving force for flow of ISF out of the parenchyma [7]. Retinal vessel analysis (RVA) allows non-invasive measurement of retinal vessel vasomotion with respect to diameter changes [8]. Thus, the aim of the study is to investigate vasomotion in RVA signals of SAH and PHH patients.
Solar sails provide ignificant advantages over other low-thrust propulsion systems because they produce thrust by the momentum exchange from solar radiation pressure (SRP) and thus do not consume any propellant.The force exerted on a very thin sail foil basically depends on the light incidence angle. Several analytical SRP force models that describe the SRP force acting on the sail have been established since the 1970s. All the widely used models use constant optical force coefficients of the reflecting sail material. In 2006,MENGALI et al. proposed a refined SRP force model that takes into account the dependancy of the force coefficients on the light incident angle,the sail’s distance from the sun (and thus the sail emperature) and the surface roughness of the sail material [1]. In this paper, the refined SRP force model is compared to the previous ones in order to identify the potential impact of the new model on the predicted capabilities of solar sails in performing low-cost interplanetary space missions. All force models have been implemented within InTrance, a global low-thrust trajectory optimization software utilizing evolutionary neurocontrol [2]. Two interplanetary rendezvous missions, to Mercury and the near-Earth asteroid 1996FG3, are investigated. Two solar sail performances in terms of characteristic acceleration are examined for both scenarios, 0.2 mm/s2 and 0.5 mm/s2, termed “low” and “medium” sail performance. In case of the refined SRP model, three different values of surface roughness are chosen, h = 0 nm, 10 nm and 25 nm. The results show that the refined SRP force model yields shorter transfer times than the standard model.
Lightning safety guidelines
(2010)
This paper introduces lightning to the layman, noting the right behaviour in front of thunderstorms as well as protective measures against lightning. It also contributes to the prevention of lightning injuries and damages. This report was prepared by the authors inside the AHG1 Group for IEC TC81 (Lightning Protection).
Motivation-based Learning: Teaching Fundamentals of Electrical Engineering with an LED Spinning Top
(2018)
Der Internally Commutated Thyristor (ICT) : ein neuartiger GCT mit integrierter Ausschalteinheit
(2007)
Physical layer specification of the L-band Digital Aeronautical Communications System (L-DACS1)
(2009)
The increasing digitalization brings new opportunities but also puts new challenges to modern industrial systems. Software agents are one of the key technologies towards self-optimizing factories and are currently used to address the needs of cyber-physical production systems (CPPS). However their interplay in industrial settings needs to be understood better.This paper focusses on securing a cloud infrastructure for multi-agent systems for industrial sites. An industrial site contains multiple production processes that need to communicate with each other and each physical resource is abstracted with a software agent. This volatile architecture needs to be managed and protected from manipulation. The proposed infrastructure presents a security concept for TCP/IP communication between agents, machines, and external networks. It is based on open-source software and tested on a three-node edge cloud controlling a model-plant.
Light-stimulated hydrogel actuators with incorporated graphene oxide for microfluidic applications
(2015)
Optimierung des potentiellen Sauerstoffeintrags auf Treppenschussrinnen mit gemäßigter Neigung
(2009)
Sensitivity of phase detection techniques in aerated chute flows to hydraulic design parameters
(2012)
The major advantage of labyrinth weirs over linear weirs is hydraulic efficiency. In hydraulic modeling efforts, this strength contrasts with limited pump capacity as well as limited computational power for CFD simulations. For the latter, reducing the number of investigated cycles can significantly reduce necessary computational time. In this study, a labyrinth weir with different cycle numbers was investigated. The simulations were conducted in FLOW-3D HYDRO as a Large Eddy Simulation. With a mean deviation of 1.75 % between simulated discharge coefficients and literature design equations, a reasonable agreement was found. For downstream conditions, overall consistent results were observed as well. However, the orientation of labyrinth weirs with a single cycle should be chosen carefully under consideration of the individual research purpose.
Optimization of the reaeration potential on embankment stepped spillways in skimming flow regime
(2008)
Application of the optical flow method to velocity determination in hydraulic structure models
(2016)
Fields of asymmetric tensors play an important role in many applications such as medical imaging (diffusion tensor magnetic resonance imaging), physics, and civil engineering (for example Cauchy-Green-deformation tensor, strain tensor with local rotations, etc.). However, such asymmetric tensors are usually symmetrized and then further processed. Using this procedure results in a loss of information. A new method for the processing of asymmetric tensor fields is proposed restricting our attention to tensors of second-order given by a 2x2 array or matrix with real entries. This is achieved by a transformation resulting in Hermitian matrices that have an eigendecomposition similar to symmetric matrices. With this new idea numerical results for real-world data arising from a deformation of an object by external forces are given. It is shown that the asymmetric part indeed contains valuable information.
Industrial facilities must be thoroughly designed to withstand seismic actions as they exhibit an increased loss potential due to the possibly wideranging damage consequences and the valuable process engineering equipment. Past earthquakes showed the social and political consequences of seismic damage to industrial facilities and sensitized the population and politicians worldwide for the possible hazard emanating from industrial facilities. However, a holistic approach for the seismic design of industrial facilities can presently neither be found in national nor in international standards. The introduction of EN 1998-4 of the new generation of Eurocode 8 will improve the normative situation with
specific seismic design rules for silos, tanks and pipelines and secondary process components. The article presents essential aspects of the seismic design of industrial facilities based on the new generation of Eurocode 8 using the example of tank structures and secondary process components. The interaction effects of the process components with the primary structure are illustrated by means of the experimental results of a shaking table test of a three story moment resisting steel frame with different process components. Finally, an integrated approach of
digital plant models based on building information modelling (BIM) and structural health monitoring (SHM) is presented, which provides not only a reliable decision-making basis for operation, maintenance and repair but also an excellent tool for rapid assessment of seismic damage.
Nowadays modern high-performance buildings and facilities are equipped with monitoring systems and sensors to control building characteristics like energy consumption, temperature pattern and structural safety. The visualization and interpretation of sensor data is typically based on simple spreadsheets and non-standardized user-oriented solutions, which makes it difficult for building owners, facility managers and decision-makers to evaluate and understand the data. The solution of this problem in the future are integrated BIM-Sensor approaches which allow the generation of BIM models incorporating all relevant information of monitoring systems. These approaches support both the dynamic visualization of key structural performance parameters, the effective long-term management of sensor data based on BIM and provide a user-friendly interface to communicate with various stakeholders. A major benefit for the end user is the use of the BIM software architecture, which is the future standard anyway. In the following, the application of the integrated BIM-Sensor approach is illustrated for a typical industrial facility as a part of an early warning and rapid response system for earthquake events currently developed in the research project “ROBUST” with financial support by the German Federal Ministry for Economic Affairs and Energy (BMWI).
Past earthquakes demonstrated the high vulnerability of industrial facilities equipped with complex process technologies leading to serious damage of the process equipment and multiple and simultaneous release of hazardous substances in industrial facilities. Nevertheless, the design of industrial plants is inadequately described in recent codes and guidelines, as they do not consider the dynamic interaction between the structure and the installations and thus the effect of seismic response of the installations on the response of the structure and vice versa. The current code-based approach for the seismic design of industrial facilities is considered not enough for ensure proper safety conditions against exceptional event entailing loss of content and related consequences. Accordingly, SPIF project (Seismic Performance of Multi-Component Systems in Special Risk Industrial Facilities) was proposed within the framework of the European H2020 - SERA funding scheme (Seismology and Earthquake Engineering Research Infrastructure Alliance for Europe). The objective of the SPIF project is the investigation of the seismic behaviour of a representative industrial structure equipped with complex process technology by means of shaking table tests. The test structure is a three-story moment resisting steel frame with vertical and horizontal vessels and cabinets, arranged on the three levels and connected by pipes. The dynamic behaviour of the test structure and of its relative several installations is investigated. Furthermore, both process components and primary structure interactions are considered and analyzed. Several PGA-scaled artificial ground motions are applied to study the seismic response at different levels. After each test, dynamic identification measurements are carried out to characterize the system condition. The contribution presents the experimental setup of the investigated structure and installations, selected measurement data and describes the obtained damage. Furthermore, important findings for the definition of performance limits, the effectiveness of floor response spectra in industrial facilities will be presented and discussed.
Reinforced concrete (RC) frames with masonry infills are frequently used in seismic regions all over the world. Generally masonry infills are considered as nonstructural elements and thus are typically neglected in the design process. However, the observations made after strong earthquakes have shown that masonry infills can modify the dynamic behavior of the structure significantly. The consequences were total collapses of buildings and loss of human lives. This paper presents the new system INODIS (Innovative Decoupled Infill System) developed within the European research project INSYSME (Innovative Systems for Earthquake Resistant Masonry Enclosures in RC Buildings). INODIS decouples the frame and the masonry infill by means of special U-shaped rubbers placed in between frame and infill. The effectiveness of the system was investigated by means of full scale tests on RC frames with masonry infills subjected to in-plane and out-of-plane loading. Furthermore small specimen tests were conducted to determine material characteristics of the components and the resistances of the connections. Finally, a micromodel was developed to simulate the in-plane behavior of RC frames infilled with AAC blocks with and without installation of the INODIS system.
Past earthquakes demonstrated the high vulnerability of industrial facilities equipped with complex process technologies leading to serious damage of the process equipment and multiple and simultaneous release of hazardous substances in industrial facilities. Nevertheless, the design of industrial plants is inadequately described in recent codes and guidelines, as they do not consider the dynamic interaction between the structure and the installations and thus the effect of seismic response of the installations on the response of the structure and vice versa. The current code-based approach for the seismic design of industrial facilities is considered not enough for ensure proper safety conditions against exceptional event entailing loss of content and related consequences. Accordingly, SPIF project (Seismic Performance of Multi- Component Systems in Special Risk Industrial Facilities) was proposed within the framework of the European H2020 - SERA funding scheme (Seismology and Earthquake Engineering Research Infrastructure Alliance for Europe). The objective of the SPIF project is the investigation of the seismic behavior of a representative industrial structure equipped with complex process technology by means of shaking table tests. The test structure is a three-story moment resisting steel frame with vertical and horizontal vessels and cabinets, arranged on the three levels and connected by pipes. The dynamic behavior of the test structure and installations is investigated with and without base isolation. Furthermore, both firmly anchored and isolated components are taken into account to compare their dynamic behavior and interactions with each other. Artificial and synthetic ground motions are applied to study the seismic response at different PGA levels. After each test, dynamic identification measurements are carried out to characterize the system condition. The contribution presents the numerical simulations to calibrate the tests on the prototype, the experimental setup of the investigated structure and installations, selected measurement data and finally describes preliminary experimental results.