Article
Refine
Year of publication
- 2003 (154) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (39)
- INB - Institut für Nano- und Biotechnologien (27)
- Fachbereich Wirtschaftswissenschaften (25)
- Fachbereich Maschinenbau und Mechatronik (17)
- IfB - Institut für Bioengineering (15)
- Fachbereich Elektrotechnik und Informationstechnik (14)
- Fachbereich Bauingenieurwesen (13)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Energietechnik (12)
- Fachbereich Chemie und Biotechnologie (8)
Document Type
- Article (154) (remove)
Keywords
- Blitzschutz (2)
- Lightning protection (2)
- Alternative Energiequelle (1)
- Analysis (1)
- Architektur (1)
- Bauingenieurwesen (1)
- CAD (1)
- Cement infiltration (1)
- Digital Museum (1)
- Digitales Museum (1)
Cement augmentation is an emerging surgical procedure in which bone cement is used to infiltrate and reinforce osteoporotic vertebrae. Although this infiltration procedure has been widely applied, it is performed empirically and little is known about the flow characteristics of cement during the injection process. We present a theoretical and experimental approach to investigate the intertrabecular bone permeability during the infiltration procedure. The cement permeability was considered to be dependent on time, bone porosity, and cement viscosity in our analysis. In order to determine the time-dependent permeability, ten cancellous bone cores were harvested from osteoporotic vertebrae, infiltrated with acrylic cement at a constant flow rate, and the pressure drop across the cores during the infiltration was measured. The viscosity dependence of the permeability was determined based on published experimental data. The theoretical model for the permeability as a function of bone porosity and time was then fit to the testing data. Our findings suggest that the intertrabecular bone permeability depends strongly on time. For instance, the initial permeability (60.89 mm4/N.s) reduced to approximately 63% of its original value within 18 seconds. This study is the first to analyze cement flow through osteoporotic bone. The theoretical and experimental models provided in this paper are generic. Thus, they can be used to systematically study and optimize the infiltration process for clinical practice.
Die Eignung von Baggergut als mineralische Komponente in Deponie-Oberflächenabdichtungssystemen
(2003)
Sanierung des ehemaligen Gaswerkgeländes am Bremer Hauptbahnhof / K. Konertz ; E. Biener ; T. Sasse
(2003)
Das von Texas-Instruments (TI) vertriebene Interface CBL2 wird über einige TI-Grafik-Rechner (TI-92, TI-89 usw.) angesteuert. Wegen seiner Handlichkeit wird dieses System beim Unterricht in wechselnden Räumen »großen« Messwerterfassungssystemen oft vorgezogen. Das CBL2 bietet drei analoge Eingänge, die immerhin mit 10 Bit Auflösung und bis zu einer Frequenz von 50 kHz arbeiten. Weiterhin besitzt das CBL2 eine Buchse für angeblich nur einen digitalen Ein- bzw. Ausgang. An diesem Eingang wird standardmäßig hauptsächlich der Bewegungssensor CBR betrieben. In diesem Beitrag werden Erweiterungsmöglichkeiten dieses Anschlusses beschrieben.
Couponing
(2003)
Solar sailcraft of the first generation technology development / Seboldt, Wolfgang ; Dachwald, Bernd
(2003)
Kunstwerke sowie ihre Präsentation und Vermittlung werden zunehmend von digitalen Technologien unterstützt. Virtuelle Ausstellungen, Internet-Projekte und komplexe Datenarchive stellen das Kunstwerk in einen medialen Kontext, der weit über das Moment einer technischen Reproduzierbarkeit hinausgeht. Das allgegenwärtige Konzept der Vernetzung dynamisiert Kunst, ihre Rezipienten und Ausstellungsorte. Die Beziehungen zwischen diesen Feldern werden mit Hilfe physiologischer Metaphern definiert und visualisiert. Frühere Speicher und Archive geraten in einen prozessualen Sog, in dem alles fluktuiert, sich kurzweilig verknüpft, auflöst und in permanente Dialoge mit seiner Umgebung tritt - das virtuelle Museum gerät in aktuellen Standortbestimmungen in die definitorische Nähe des Künstlichen Lebens.
Layer Deposition I
(2003)
Entrauchung über Seitenwände
(2003)
Seßlestalbrücke - Verbundbrücke mit einteiligem Querschnitt / Wanzek, Thorsten; Gossla, Ulrich
(2003)
Within the Crystal Clear Collaboration (CCC), four centers are developing second generation high performance small animal positron emission tomography (PET) scanners for different kinds of animals and medical applications. The first prototypes are photomultiplier tube (PMT)-based systems including depth of interaction (DOI) detection by using a phoswich layer of lutetium oxyorthosilicate (LSO) and lutetium yttrium aluminum perovskite (LuYAP). The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in fields of view (FOVs) caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN, Geneva, Switzerland) was used.
Within the Crystal Clear Collaboration four centres are developing 2nd generation high performance small animal PET scanners for different kinds of animals and medical applications. The first prototypes are PMT-based systems including depth of interaction (DOI) detection by using a phoswich layer of LSO and LuYAP. The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in FOVs caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN) was used. The simulations have shown that all PMT designs with one-to-one coupling of crystals have a very nonlinear axial sensitivity profile. By shifting every other PMT 1/4 of a PMT length in axial direction the sampling of the FOVs became more homogeneous. At an energy threshold of 350keV the regression coefficient increases from 0.818 for the non-shifted to 0.993 for the shifted design. Simulations of a point source centred in the FOV (threshold: 350keV) resulted in sensitivities of 4.2% for a 4×20PMT (LSO/LuYAP a 10mm) and 3.8% for a 4×16PMT (LSO/LuYAP a 8mm) ring design. The 3D-MLEM reconstruction of a point source shows the enormous improvement of resolution using a crystal double layer with DOI (3.1mm at 40mm from CFOV) instead of a 20mm single layer (11.9mm).
Untersuchung eines hybriden EMV-Simulationsverfahrens anhand eines virtuellen Komponententests
(2003)
Ein vorausschauendes Risikomanagement beinhaltet, Risiken zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent,welche Risiken sinnvoll über Versicherungen abgedeckt werden sollten. Bei Unternehmen, die mit umfangreichen elektronischenEinrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nichtverfügbarkeit der elektronischen Einrichtungen und damit derProduktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardwareschaden an der betroffenen Anlage oft bei weitem übersteigt.
Dem Blitzschutz von Anlagen der regenerativen Energien kommt in Zukunft eine steigende Bedeutung zu. Dabei ist es notwendig zu berücksichtigen, dass die Schutzmaßnahmen technisch/wirtschaftlich ausgewogen sind. Erbauer, Besitzer oder Benutzer von netzautarken Hybridanlagen haben zu entscheiden, ob die Anlage einen Schutz braucht oder nicht. Um diese Entscheidung zu fällen, ist eine Risikoanalyse als erster Schritt sinnvoll. Diese muss dabei die für die Hybridanlage relevanten Schadenarten und spezifischen Parameter, Werte und Randbedingungen mit einbeziehen. Dazu ist die Hilfe eines Blitzschutzexperten sehr hilfreich.
Sonderbilanz und Status
(2003)
The Virtual Clean Room - a new tool in teaching MST process technologies University education in high-technology fields like MST is not complete without intensive laboratory sessions. Students cannot fully grasp the complexity and the special problems related to the manufacturing of microsystems without a thorough hands-on experience in a MST clean room.