A capacitive electrolyte-insulator-semiconductor (EISCAP) biosensor modified with Tobacco mosaic virus (TMV) particles for the detection of acetoin is presented. The enzyme acetoin reductase (AR) was immobilized on the surface of the EISCAP using TMV particles as nanoscaffolds. The study focused on the optimization of the TMV-assisted AR immobilization on the Ta 2 O 5 -gate EISCAP surface. The TMV-assisted acetoin EISCAPs were electrochemically characterized by means of leakage-current, capacitance-voltage, and constant-capacitance measurements. The TMV-modified transducer surface was studied via scanning electron microscopy.
In aseptischen Abfüllsystemen wird Wasserstoffperoxid in der Gasphase aufgrund der stark oxidativen Wirkung zur Packstoffentkeimung eingesetzt. Dabei wird die Effizienz der Entkeimung im Wesentlichen von der vorliegenden H2O2-Konzentration im Packstoff bestimmt. Zur Inline-Überwachung der H2O2-Konzentration wurde ein kalorimetrischer Gassensor auf Basis einer flexiblen Polyimidfolie aus temperatursensitiven Dünnschicht-Widerständen und Mangan(IV)-oxid als katalytische Transducerschicht realisiert. Der Sensor weist ein lineares Ansprechverhalten mit einer Sensitivität von 7,15 °C/Vol.-% in einem H2O2-Konzentrationsbereich von 0 bis 8 Vol.-% auf. Weiterhin wurde zur Auslesung des Sensorsignals eine RFID-Elektronik, bestehend aus einem Sensor-Tag und einer Sende-/Empfangseinheit ausgelegt, sowie eine Abfolge des Messzyklus aufgestellt. Im weiteren Verlauf soll der kalorimetrische Gassensor mit der RFID-Elektronik gekoppelt und in eine Testverpackung zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllsystemen implementiert werden.
Ein lichtadressierbarer potentiometrischer Sensor (LAPS) kann die Konzentration eines oder mehrerer Analyten ortsaufgelöst auf der Sensoroberfläche nachweisen. Dazu wird mit einer modulierten Lichtquelle die Halbleiterstruktur des zu untersuchenden Bereiches angeregt und ein entsprechender Photostrom ausgelesen. Durch gleichzeitige Anregung mehrere Bereiche durch Lichtquellen mit unterschiedlichen Modulationsfrequenzen können diese auch zeitgleich ausgelesen werden. Mit der neuen, hier vorgestellten Ansteuerungselektronik integriert in einem "Field Programmable Gate Array" (FPGA) ist es möglich, mehrere Leuchtquellen gleichzeitig mit unterschiedlichen, während der Laufzeit festlegbaren Frequenzen, Phasen und Lichtintensitäten zu betreiben. Somit kann das Frequenzverhalten des Sensors untersucht und die Konzentration des Analyten über das Oberflächenpotential mit Hilfe von Strom/Spannungs-Kurven und Phase/Spannungs-Kurven bestimmt werden.
Multi-parameter detection for supporting monitoring and control of biogas processes in agriculture
(2014)
Light-stimulated hydrogel actuators with incorporated graphene oxide for microfluidic applications
(2015)
Label-free sensing of biomolecules by their intrinsic molecular charge using field-effect devices
(2015)
Label-free Electrostatic Detection of DNA Amplification by PCR Using Capacitive Field-effect Devices
(2016)
A capacitive field-effect EIS (electrolyte-insulator-semiconductor) sensor modified with a positively charged weak polyelectrolyte of poly(allylamine hydrochloride) (PAH)/single-stranded probe DNA (ssDNA) bilayer has been used for a label-free electrostatic detection of pathogen-specific DNA amplification via polymerase chain reaction (PCR). The sensor is able to distinguish between positive and negative PCR solutions, to detect the existence of target DNA amplicons in PCR samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process.
Heavy metal detection with semiconductor devices based on PLD-prepared chalcogenide glass thin films
(2007)
DNA-hybridization detection using light-addressable potentiometric sensor modified with gold layer
(2014)
Detection of Adrenaline Based on Bioelectrocatalytical System to Support Tumor Diagnostic Technology
(2017)
Chemische Sensoren mit Bariumstrontiumtitanat als funktionelle Schicht zur Multiparameterdetektion
(2013)
Es wurde ein automatisiertes, computerunterstütztes Testsystem für die Funktionsprüfung und Charakterisierung von (bio-)chemischen Sensoren auf Waferebene entwickelt und in einen konventionellen Spitzenmessplatz integriert. Das System ermöglicht die Charakterisierung und Identifizierung „funktionstauglicher“ Sensoren bereits auf Waferebene zwischen den einzelnen Herstellungsschritten, wodurch weitere, bisher übliche Verarbeitungsschritte wie das Fixieren, Bonden und Verkapseln für die defekten oder nicht funktionstauglichen Sensorstrukturen entfällt. Außerdem bietet eine speziell entworfene miniaturisierte Durchflussmesszelle die Möglichkeit, bereits auf Waferlevel die Sensitivität, Drift, Hysterese und Ansprechzeit der (bio-)chemischen Sensoren zu charakterisieren. Das System wurde exemplarisch mit kapazitiven, pH-sensitiven EIS- (Elektrolyt-Isolator-Silizium) Strukturen und ISFET- (ionensensitiver Feldeffekttransistor) Strukturen mit verschiedenen Geometrien und Gate-Layouts getestet.
An application of a scanning light-addressable potentiometric sensor for label-free DNA detection
(2013)