Article
Refine
Year of publication
- 2003 (154) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (39)
- INB - Institut für Nano- und Biotechnologien (27)
- Fachbereich Wirtschaftswissenschaften (25)
- Fachbereich Maschinenbau und Mechatronik (17)
- IfB - Institut für Bioengineering (15)
- Fachbereich Elektrotechnik und Informationstechnik (14)
- Fachbereich Bauingenieurwesen (13)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Energietechnik (12)
- Fachbereich Chemie und Biotechnologie (8)
Document Type
- Article (154) (remove)
Keywords
- Blitzschutz (2)
- Lightning protection (2)
- Alternative Energiequelle (1)
- Analysis (1)
- Architektur (1)
- Bauingenieurwesen (1)
- CAD (1)
- Cement infiltration (1)
- Digital Museum (1)
- Digitales Museum (1)
Das von Texas-Instruments (TI) vertriebene Interface CBL2 wird über einige TI-Grafik-Rechner (TI-92, TI-89 usw.) angesteuert. Wegen seiner Handlichkeit wird dieses System beim Unterricht in wechselnden Räumen »großen« Messwerterfassungssystemen oft vorgezogen. Das CBL2 bietet drei analoge Eingänge, die immerhin mit 10 Bit Auflösung und bis zu einer Frequenz von 50 kHz arbeiten. Weiterhin besitzt das CBL2 eine Buchse für angeblich nur einen digitalen Ein- bzw. Ausgang. An diesem Eingang wird standardmäßig hauptsächlich der Bewegungssensor CBR betrieben. In diesem Beitrag werden Erweiterungsmöglichkeiten dieses Anschlusses beschrieben.
Entrauchung über Seitenwände
(2003)
Dot net und Sun ONE - Wettbewerb oder Mitspieler? Neue Programmiermodelle machen das Web interaktiv
(2003)
Die Eignung von Baggergut als mineralische Komponente in Deponie-Oberflächenabdichtungssystemen
(2003)
Within the Crystal Clear Collaboration (CCC), four centers are developing second generation high performance small animal positron emission tomography (PET) scanners for different kinds of animals and medical applications. The first prototypes are photomultiplier tube (PMT)-based systems including depth of interaction (DOI) detection by using a phoswich layer of lutetium oxyorthosilicate (LSO) and lutetium yttrium aluminum perovskite (LuYAP). The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in fields of view (FOVs) caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN, Geneva, Switzerland) was used.
Within the Crystal Clear Collaboration four centres are developing 2nd generation high performance small animal PET scanners for different kinds of animals and medical applications. The first prototypes are PMT-based systems including depth of interaction (DOI) detection by using a phoswich layer of LSO and LuYAP. The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in FOVs caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN) was used. The simulations have shown that all PMT designs with one-to-one coupling of crystals have a very nonlinear axial sensitivity profile. By shifting every other PMT 1/4 of a PMT length in axial direction the sampling of the FOVs became more homogeneous. At an energy threshold of 350keV the regression coefficient increases from 0.818 for the non-shifted to 0.993 for the shifted design. Simulations of a point source centred in the FOV (threshold: 350keV) resulted in sensitivities of 4.2% for a 4×20PMT (LSO/LuYAP a 10mm) and 3.8% for a 4×16PMT (LSO/LuYAP a 8mm) ring design. The 3D-MLEM reconstruction of a point source shows the enormous improvement of resolution using a crystal double layer with DOI (3.1mm at 40mm from CFOV) instead of a 20mm single layer (11.9mm).
Kunstwerke sowie ihre Präsentation und Vermittlung werden zunehmend von digitalen Technologien unterstützt. Virtuelle Ausstellungen, Internet-Projekte und komplexe Datenarchive stellen das Kunstwerk in einen medialen Kontext, der weit über das Moment einer technischen Reproduzierbarkeit hinausgeht. Das allgegenwärtige Konzept der Vernetzung dynamisiert Kunst, ihre Rezipienten und Ausstellungsorte. Die Beziehungen zwischen diesen Feldern werden mit Hilfe physiologischer Metaphern definiert und visualisiert. Frühere Speicher und Archive geraten in einen prozessualen Sog, in dem alles fluktuiert, sich kurzweilig verknüpft, auflöst und in permanente Dialoge mit seiner Umgebung tritt - das virtuelle Museum gerät in aktuellen Standortbestimmungen in die definitorische Nähe des Künstlichen Lebens.
Couponing
(2003)
Application of a (bio-)chemical sensor (ISFET) for the detection of physical parameters in liquids
(2003)