Refine
Year of publication
- 2024 (21)
- 2023 (22)
- 2022 (42)
- 2021 (43)
- 2020 (57)
- 2019 (64)
- 2018 (59)
- 2017 (60)
- 2016 (41)
- 2015 (59)
- 2014 (52)
- 2013 (53)
- 2012 (58)
- 2011 (65)
- 2010 (58)
- 2009 (66)
- 2008 (50)
- 2007 (40)
- 2006 (37)
- 2005 (36)
- 2004 (68)
- 2003 (38)
- 2002 (44)
- 2001 (46)
- 2000 (47)
- 1999 (29)
- 1998 (24)
- 1997 (22)
- 1996 (21)
- 1995 (16)
- 1994 (11)
- 1993 (16)
- 1992 (7)
- 1991 (5)
- 1990 (11)
- 1989 (10)
- 1988 (16)
- 1987 (6)
- 1986 (2)
- 1985 (2)
- 1984 (1)
- 1983 (2)
- 1982 (20)
- 1981 (13)
- 1980 (27)
- 1979 (18)
- 1978 (26)
- 1977 (13)
- 1976 (12)
- 1975 (9)
- 1974 (2)
- 1973 (1)
- 1972 (2)
- 1968 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1571) (remove)
Has Fulltext
- no (1571) (remove)
Language
- English (1571) (remove)
Document Type
- Article (1316)
- Conference Proceeding (135)
- Book (43)
- Part of a Book (43)
- Doctoral Thesis (18)
- Other (6)
- Patent (4)
- Preprint (3)
- Conference: Meeting Abstract (1)
- Habilitation (1)
Keywords
- LAPS (4)
- Natural language processing (4)
- CellDrum (3)
- Field-effect sensor (3)
- Light-addressable potentiometric sensor (3)
- Paired sample (3)
- hydrogen peroxide (3)
- impedance spectroscopy (3)
- Bacillus atrophaeus (2)
- Biocomposites (2)
Objective
To investigate whether functional brain networks of epilepsy patients treated with antiepileptic medication differ from networks of healthy controls even during the seizure-free interval.
Methods
We applied different rules to construct binary and weighted networks from EEG and MEG data recorded under a resting-state eyes-open and eyes-closed condition from 21 epilepsy patients and 23 healthy controls. The average shortest path length and the clustering coefficient served as global statistical network characteristics.
Results
Independent on the behavioral condition, epileptic brains exhibited a more regular functional network structure. Similarly, the eyes-closed condition was characterized by a more regular functional network structure in both groups. The amount of network reorganization due to behavioral state changes was similar in both groups. Consistent findings could be achieved for networks derived from EEG but hardly from MEG recordings, and network construction rules had a rather strong impact on our findings.
Conclusions
Despite the locality of the investigated processes epileptic brain networks differ in their global characteristics from non-epileptic brain networks. Further methodological developments are necessary to improve the characterization of disturbed and normal functional networks.
Significance
An increased regularity and a diminished modulation capability appear characteristic of epileptic brain networks.
Epilepsy
(2010)
We consider recent reports on small-world topologies of interaction networks derived from the dynamics of spatially extended systems that are investigated in diverse scientific fields such as neurosciences, geophysics, or meteorology. With numerical simulations that mimic typical experimental situations, we have identified an important constraint when characterizing such networks: indications of a small-world topology can be expected solely due to the spatial sampling of the system along with the commonly used time series analysis based approaches to network characterization.
Recently, we introduced and mathematically analysed a new method for grid deformation (Grajewski et al., 2009) [15] we call basic deformation method (BDM) here. It generalises the method proposed by Liao et al. (Bochev et al., 1996; Cai et al., 2004; Liao and Anderson, 1992) [4], [6], [20]. In this article, we employ the BDM as core of a new multilevel deformation method (MDM) which leads to vast improvements regarding robustness, accuracy and speed. We achieve this by splitting up the deformation process in a sequence of easier subproblems and by exploiting grid hierarchy. Being of optimal asymptotic complexity, we experience speed-ups up to a factor of 15 in our test cases compared to the BDM. This gives our MDM the potential for tackling large grids and time-dependent problems, where possibly the grid must be dynamically deformed once per time step according to the user's needs. Moreover, we elaborate on implementational aspects, in particular efficient grid searching, which is a key ingredient of the BDM.
Self metathesis of oleochemicals offers a variety of bifunctional compounds, that can be used as monomer for polymer production. Many precursors are in huge scales available, like oleic acid ester (biodiesel), oleyl alcohol (tensides), oleyl amines (tensides, lubricants). We show several ways to produce and separate and purify C18-α,ω-bifunctional compounds, using Grubbs 2nd Generation catalysts, starting from technical grade educts.
Autonomous robotic systems for penetrating thick ice shells with simultaneous collecting of scientific data are very promising devices in both terrestrial (glacier, climate research) and extra-terrestrial applications. Technical challenges in development of such systems are numerous and include 3D-navigation, an appropriate energy source, motion control, etc. Not less important is the problem of forward contamination of the pristine glacial environments with microorganisms and biomolecules from the surface of the probe. This study was devoted to establishing a laboratory model for microbial contamination of a newly constructed ice-melting probe called IceMole and to analyse the viability and amount of the contaminating microorganisms as a function of distance. The used bacterial strains were Bacillus subtilis (ATCC 6051) and Escherichia coli (ATCC 11775). The main objective was development of an efficient and reliable in-situ decontamination method of the melting probe. Therefore, several chemical substances were tested in respect of their efficacy to eliminate bacteria on the surface of the melting probe at low temperature (0 - 5 °C) and at continuous dilution by melted water. Our study has shown that at least 99.9% decontamination of the IceMole can be successfully achieved by the injection of 30% (v/v) hydrogen peroxide and 3% (v/v) sodium hypochlorite into the drilling site. We were able to reproduce this result in both time-dependent and depth-dependent experiments. The sufficient amount of 30% (v/v) H₂O₂ or 3% (v/v) NaClO has been found to be approximately 18 L per cm² of the probe’s surface.
The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the currentvoltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated.
Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry
(2010)
A calorimetric gas sensor is presented for the monitoring of gas-phase H2O2 at elevated temperature during sterilization processes in aseptic food industry. The sensor consists of two temperature-sensitive thin-film resistances built up on a polyimide foil with a thickness of 25 μm, which are passivated with a layer of SU-8 photo resist and catalytically activated with manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilizes the elevated temperature of an evaporated H2O2 aerosol. In an experimental set-up, the sensor has shown a sensitivity of 4.78 °C/(%v/v) in a H2O2 concentration range of 0 to 10% v/v at an evaporation temperature of 240 ∘C. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied evaporation temperatures of the gas stream. The sensor characterization demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of sterilization processes.
In this contribution, we focus on the detection of toxic gases with living eukaryotic cells. A cell-based gas sensor system, able to measure the effects of direct exposure of gases to cells in real-time, was set up. Impedance data as well as oxygen consumption of Chinese hamster lung fibroblast cells (V79) were analysed upon exposure to carbon monoxide (CO). The CO (diluted in wet synthetic air) affects the cell respiration as indicated by an attenuated respiration signal after the CO exposure as well as an instant increase of the capacitive part of the impedance signal during the gas exposure.
Chalcogenide glass materials as membranes for potentiometric sensors for chemical analysis in solutions have been studied since more than 20 years. In this work, an electrolyte–insulator–semiconductor structure was combined with chalcogenide glass membranes prepared by means of the pulsed laser deposition technique. Depending on the membrane composition a selectivity to different ions (Cd2+ and Pb2+) is achieved. The different sensor membranes have been physically characterised using microscopy, ellipsometry, profilometry, atomic force microscopy (AFM), scanning electron microscopy (SEM) and Rutherford backscattering spectrometry (RBS). The electrochemical behaviour has been investigated via capacitance/voltage (C/V) and constant capacitance (ConCap) measurements and results in a Cd2+ sensitivity of 23.1 ± 0.6 mV per decade in a linear range from 7 × 10−6 to 10−2 mol/l and 24.4 ± 0.5 mV per decade in a linear range from 5 × 10−6 to 10−2 mol/l for Pb2+, respectively.
The importance of validating and reproducing the outcome of computational processes is fundamental to many application domains. Assuring the provenance of workflows will likely become even more important with respect to the incorporation of human tasks to standard workflows by emerging standards such as WS-HumanTask. This paper addresses this trend by an actor-based workflow approach that actively support provenance. It proposes a framework to track and store provenance information automatically that applies for various workflow management systems. In particular, the introduced provenance framework supports the documentation of workflows in a legally binding way. The authors therefore use the concept of layered XML documents, i.e. history-tracing XML. Furthermore, the proposed provenance framework enables the executors (actors) of a particular workflow task to attest their operations and the associated results by integrating digital XML signatures.
Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach of read out in a light-addressable potentiometric sensor (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device which allows fast and flexible generation of light patterns. With the help of these light patterns the sensor surface of the LAPS device can be read out sequentially in a raster like scheme (scanning LAPS). The DLP approach has several advantages compared to conventional scanning LAPS set-ups, e.g., the spot size, the shape and the intensity of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of measurement.
A new approach for a label-free electrical detection of DNA hybridization and denaturation using an array of individually addressable field-effect nanoplate SOI (silicon-on-insulator) capacitors functionalized with gold nanoparticles is presented. By using a constant-capacitance measuring setup in a differential mode, signal changes of ∼110 mV and ∼70 mV have been registered after the DNA hybridization and denaturation events, respectively.
Currently, most workflow management systems in Grid environments provide push-oriented job distribution strategies, where jobs are explicitly delegated to resources. In those scenarios the dedicated resources execute submitted jobs according to the request of a workflow engine or Grid wide scheduler. This approach has various limitations, particularly if human interactions should be integrated in workflow execution. To support human interactions with the benefit of enabling inter organizational computation and community approaches, this poster paper proposes the idea of a pull-based task distribution strategy. Here, heterogeneous resources, including human interaction, should actively select tasks for execution from a central repository. This leads to special demands regarding security issues like access control. In the established push-based job execution the resources are responsible for granting access to workflows and job initiators. In general this is done by access control lists, where users are explicitly mapped to local accounts according to their policies. In the pull-based approach the resources actively apply for job executions by sending requests to a central task repository. This means that every resource has to be able to authenticate against the repository to be authorized for task execution. In other words the authorization is relocated from the resources to the repository. The poster paper introduces current work regarding to the mentioned security aspects in the pull-based approach within the scope of the project “HiX4AGWS”.
The development of new interfaces for (bio-)chemical sensors requires comprehensive analyses and testing. The light-addressable potentiometric sensor (LAPS) can be used as a platform to investigate the sensitivity of a newly developed interface towards (bio-)chemical agents. LAPS measurements are spatially resolved by utilisation of focused light beams to define individual measurement spots. In this work, a new digitally modulated LAPS set-up based on an FPGA design will be introduced to increase the number of measurement spots, to shorten the measurement time and to improve the measurement accuracy.
A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack
(2010)
A novel scheme for detecting inhomogeneous internal currents in a fuel cell stack is presented. In this paper the scheme is investigated for the case that the flow field plates consist of graphite. Then plates of high conductivity, e.g. aluminium between the flow field plates together with small slits in these plates have three effects: (a) Whenever a local inhomogeneity of the electric current occurs at a particular cell in the stack, this will induce a surface current close to that cell perpendicular to the averaged current. This current can be detected. (b) The plates of high conductivity completely prevent the inhomogeneities from spreading to neighbouring cells. (c) Even at the particular cell the inhomogeneity is suppressed as far as possible. Thus this scheme leads to much better diagnostic possibilities and at the same time reduces electric instabilities to an extent, where they probably become harmless. This scheme will first be explained for a simple model to clarify the idea. However, very precise three dimensional computations using realistic parameters are presented, corroborating the results of the simple model.
A novel tomographic scheme for analysing the state of any single membrane electrode assembly (MEA) in a stack is suggested. Plates of very high conductivity placed between every fuel cell and slitted in an appropriate manner cause surface currents at well-defined locations of the stack. We show that knowing these surface currents, information about anomalies of the currents in a MEA can be obtained using the methods of tomography. The results are mathematically not unique. However, when assuming plausible defect structures, one can exclude improbable deficiencies by applying a special form of simulated annealing. We present numerical calculations of typical examples demonstrating that the essential defects of the MEA in any single cell of the stack can be detected and their extent can be determined.
Biomechanics studies biological soft tissue materials (growth, remodeling) in vivo. For this objective, the detailed information of material properties must be well defined to construct reliable constitutive models. In the paper, the bulge test is carried out with elastomers in order to develop a test method. Then, application of the test for soft tissue materials is straightforward due to the similarities between elastomers with soft tissue materials as proved in Holzapfel 2005, Ogden 2009. It means, after the preliminary experiments and parameter identification with rubber materials has been setup, experiments on soft tissue materials can be similarly carried out. Elastomers have a complex behavior which strongly depends on the largest previous load cycle. For simplicity we consider only the first loading.
Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method
(2010)
Capacitive field-effect electrolyte-diamond-insulator-semiconductor (EDIS) structures with O-terminated nanocrystalline diamond (NCD) as sensitive gate material have been realized and investigated for the detection of pH, penicillin concentration, and layer-by-layer adsorption of polyelectrolytes. The surface oxidizing procedure of NCD thin films as well as the seeding and NCD growth process on a Si-SiO2 substrate have been improved to provide high pH-sensitive, non-porous thin films without damage of the underlying SiO2 layer and with a high coverage of O-terminated sites. The NCD surface topography, roughness, and coverage of the surface groups have been characterized by SEM, AFM and XPS methods. The EDIS sensors with O-terminated NCD film treated in oxidizing boiling mixture for 45 min show a pH sensitivity of about 50 mV/pH. The pH-sensitive properties of the NCD have been used to develop an EDIS-based penicillin biosensor with high sensitivity (65-70 mV/decade in the concentration range of 0.25-2.5 mM penicillin G) and low detection limit (5 μM). The results of label-free electrical detection of layer-by-layer adsorption of charged polyelectrolytes are presented, too.
A light-addressable potentiometric sensor (LAPS) can measure the concentration of one or several analytes at the sensor surface simultaneously in a spatially resolved manner. A modulated light pointer stimulates the semiconductor structure at the area of interest and a responding photocurrent can be read out. By simultaneous stimulation of several areas with light pointers of different modulation frequencies, the read out can be performed at the same time. With the new proposed controller electronic based on a field-programmable gate array (FPGA), it is possible to control the modulation frequencies, phase shifts, and light brightness of multiple light pointers independently and simultaneously. Thus, it is possible to investigate the frequency response of the sensor, and to examine the analyte concentration by the determination of the surface potential with the help of current/voltage curves and phase/voltage curves. Additionally, the ability to individually change the light intensities of each light pointer is used to perform signal correction.
In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit.
Can vascular function be assessed by the interpretation of retinal vascular diameter changes?
(2011)
Air-pulse corneal applanation signal curve parameters for the characterisation of keratoconus
(2011)
This paper presents a novel numerical procedure for computing limit and shakedown loads of structures using a node-based smoothed FEM in combination with a primal–dual algorithm. An associated primal–dual form based on the von Mises yield criterion is adopted. The primal-dual algorithm together with a Newton-like iteration are then used to solve this associated primal–dual form to determine simultaneously both approximate upper and quasi-lower bounds of the plastic collapse limit and the shakedown limit. The present formulation uses only linear approximations and its implementation into finite element programs is quite simple. Several numerical examples are given to show the reliability, accuracy, and generality of the present formulation compared with other available methods.
One-chip integrated dual amperometric/field-effect sensor for the detection of dissolved hydrogen
(2011)
We investigate interaction networks that we derive from multivariate time series with methods frequently employed in diverse scientific fields such as biology, quantitative finance, physics, earth and climate sciences, and the neurosciences. Mimicking experimental situations, we generate time series with finite length and varying frequency content but from independent stochastic processes. Using the correlation coefficient and the maximum cross-correlation, we estimate interdependencies between these time series. With clustering coefficient and average shortest path length, we observe unweighted interaction networks, derived via thresholding the values of interdependence, to possess non-trivial topologies as compared to Erdös-Rényi networks, which would indicate small-world characteristics. These topologies reflect the mostly unavoidable finiteness of the data, which limits the reliability of typically used estimators of signal interdependence. We propose random networks that are tailored to the way interaction networks are derived from empirical data. Through an exemplary investigation of multichannel electroencephalographic recordings of epileptic seizures – known for their complex spatial and temporal dynamics – we show that such random networks help to distinguish network properties of interdependence structures related to seizure dynamics from those spuriously induced by the applied methods of analysis.
The purpose of this study was to investigate whether sprint performance is related to lower leg musculoskeletal geometry within a homogeneous group of highly trained 100-m sprinters. Using a cluster analysis, eighteen male sprinters were divided into two groups based on their personal best (fast: N = 11, 10.30 ± 0.07 s; slow: N = 7, 10.70 ± 0.08 s). Calf muscular fascicle arrangement and Achilles tendon moment arms (calculated by the gradient of tendon excursion versus ankle joint angle) were analyzed for each athlete using ultrasonography. Achilles tendon moment arm, foot and ankle skeletal geometry, fascicle arrangement as well as the ratio of fascicle length to Achilles tendon moment arm showed no significant (p > 0.05) correlation with sprint performance, nor were there any differences in the analyzed musculoskeletal parameters between the fast and slow sprinter group. Our findings provide evidence that differences in sprint ability in world-class athletes are not a result of differences in the geometrical design of the lower leg even when considering both skeletal and muscular components.