Article
Refine
Year of publication
- 2011 (178) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (65)
- INB - Institut für Nano- und Biotechnologien (36)
- Fachbereich Elektrotechnik und Informationstechnik (25)
- Fachbereich Chemie und Biotechnologie (22)
- Fachbereich Wirtschaftswissenschaften (19)
- IfB - Institut für Bioengineering (18)
- Fachbereich Energietechnik (13)
- Fachbereich Bauingenieurwesen (12)
- Fachbereich Maschinenbau und Mechatronik (10)
- Fachbereich Luft- und Raumfahrttechnik (9)
Has Fulltext
- no (178) (remove)
Document Type
- Article (178) (remove)
Keywords
- High field MRI (1)
- MR safety (1)
- MRI (1)
- Magneto alert sensor (1)
- Pornographie (1)
- Uktrahigh field MRI (1)
- Zuschauer (1)
- avalanche (1)
- snow (1)
Möglichkeiten und Grenzen der Anwendbarkeit statisch nichtlinearer Verfahren nach DIN EN 1998-1
(2011)
Preclinical development of highly effective and safe DNA vaccines directed against HPV 16 E6 and E7
(2011)
Purpose:
At 1.5 T, real-time MRI of joint movement has been shown to be feasible. However, 7 T, provides higher SNR and thus an improved potential for parallel imaging acceleration. The purpose of this work was to build an open, U-shaped eight-channel transmit/receive microstrip coil for 7 T MRI to enable high-resolution and real-time imaging of the moving ankle joint.
Methods:
A U-shaped eight-channel transmit/receive array for the human ankle was built.urn:x-wiley:00942405:mp3399:equation:mp3399-math-0001-parameters and urn:x-wiley:00942405:mp3399:equation:mp3399-math-0002-factor were measured. SAR calculations of different ankle postures were performed to ensure patient safety. Inhomogeneities in the transmit field consequent to the open design were compensated for by the use of static RF shimming. High-resolution and real-time imaging was performed in human volunteers.
Results:
The presented array showed good performance with regard to patient comfort and image quality. High acceleration factors of up to 4 are feasible without visible acceleration artifacts. Reasonable image homogeneity was achieved with RF shimming.
Conclusions:
Open, noncylindrical designs for transmit/receive coils are practical at 7 T and real-time imaging of the moving joint is feasible with the presented coil design.
In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit.
Lignocellulosic biorefinery: Process integration of hydrolysis and fermentation (SSF process)
(2011)
The aim of the present work is the process integration and the optimization of the enzymatic hydrolysis of wood and the following fermentation of the products to ethanol. The substrate is a fiber fraction obtained by organosolv pre-treatment of beech wood. For the ethanol production, a co-fermentation by two different yeasts (Saccharomyces cerevisiae and Pachysolen tannophilus) was carried out to convert glucose as well as xylose. Two approaches has been followed: 1. A two step process, in which the hydrolysis of the fiber fraction and the fermentation to product are separated from each other. 2. A process, in which the hydrolysis and the fermentation are carried out in one single process step as simultaneous saccharification and fermentation (SSF). Following the first approach, a yield of about 0.15 g ethanol per gram substrate can be reached. Based on the SSF, one process step can be saved, and additionally, the gained yield can be raised up to 0.3 g ethanol per gram substrate.
Harmful effects of electromagnetic fields (EMF) on cognitive and behavioural features of humans and rodents have been controversially discussed and raised persistent concern about adverse effects of EMF on general brain functions. In the present study we applied radio-frequency (RF) signals of the Universal Mobile Telecommunications System (UMTS) to full brain exposed male Wistar rats in order to elaborate putative influences on stress hormone release (corticosteron; CORT and adrenocorticotropic hormone; ACTH) and on hippocampal derived synaptic long-term plasticity (LTP) and depression (LTD) as electrophysiological hallmarks for memory storage and memory consolidation. Exposure was computer controlled providing blind conditions. Nominal brain-averaged specific absorption rates (SAR) as a measure of applied mass-related dissipated RF power were 0, 2, and 10 W/kg over a period of 120 min. Comparison of cage exposed animals revealed, regardless of EMF exposure, significantly increased CORT and ACTH levels which corresponded with generally decreased field potential slopes and amplitudes in hippocampal LTP and LTD. Animals following SAR exposure of 2 W/kg (averaged over the whole brain of 2.3 g tissue mass) did not differ from the sham-exposed group in LTP and LTD experiments. In contrast, a significant reduction in LTP and LTD was observed at the high power rate of SAR (10 W/kg). The results demonstrate that a rate of 2 W/kg displays no adverse impact on LTP and LTD, while 10 W/kg leads to significant effects on the electrophysiological parameters, which can be clearly distinguished from the stress derived background. Our findings suggest that UMTS exposure with SAR in the range of 2 W/kg is not harmful to critical markers for memory storage and memory consolidation, however, an influence of UMTS at high energy absorption rates (10 W/kg) cannot be excluded.
Numerical and experimental investigation of tensile behavior of laser beam welded TRIP700 steel
(2011)
Reasoning with Qualitative Positional Information for Domestic Domains in the Situation Calculus
(2011)
Grass silage provides a great potential as renewable feedstock. Two fractions of the grass silage, a press juice and the fiber fraction, were evaluated for their possible use for bioethanol production. Direct production of ethanol from press juice is not possible due to high concentrations of organic acids. For the fiber fraction, alkaline peroxide or enzymatic pretreatment was used, which removes the phenolic acids in the cell wall. In this study, we demonstrate the possibility to integrate the enzymatic pretreatment with a simultaneous saccharification and fermentation to achieve ethanol production from grass silage in a one-process step. Achieved yields were about 53 g ethanol per kg silage with the alkaline peroxide pretreatment and 91 g/kg with the enzymatic pretreatment at concentrations of 8.5 and 14.6 g/L, respectively. Furthermore, it was shown that additional supplementation of the fermentation medium with vitamins, trace elements and nutrient salts is not necessary when the press juice is directly used in the fermentation step.
Werbung mit Garantien
(2011)
Durch die Kombination von Oligonukleotid-Liganden (Aptameren) hoher Bindungsaffinitäten
mit hochselektiv abtrennbaren magnetisierbaren Mikropartikeln
wird eine einstufige Separation von Zielmolekülen aus mikrobiologischen
Produktionsansätzen möglich. Die Aptamere werden hierfür reversibel
auf den Partikeloberflächen gebunden und für die spezifische Isolierung von
Bioprodukten eingesetzt. Die Abtrennung der beladenen Partikel erfolgt
durch einen neuen Rotor-Stator-Separator mit Hochgradient-Magnetfeld.
Das Ziel des Deutschen Corporate Governance Kodex (DCGK) besteht in der Verbesserung der Transparenz und Qualität der deutschen Corporate Governance, wobei die Sanktionierung der Nichteinhaltung des DCGK einzig durch etwaige Kapitalmarktreaktionen erfolgt. Folgende Befunde sprechen jedoch dafür, dass durch die Abgabe der Entsprechenserklärung gem. § 161 AktG die für das Enforcement des Kodex angenommene Selbstregulierung durch den Kapitalmarkt nicht stattfindet, und demnach Verbesserungsbedarf besteht
Objective
To investigate the feasibility of 7T MR imaging of the kidneys utilising a custom-built 8-channel transmit/receive radiofrequency body coil.
Methods
In vivo unenhanced MR was performed in 8 healthy volunteers on a 7T whole-body MR system. After B0 shimming the following sequences were obtained: 1) 2D and 3D spoiled gradient-echo sequences (FLASH, VIBE), 2) T1-weighted 2D in and opposed phase 3) True-FISP imaging and 4) a T2-weighted turbo spin echo (TSE) sequence. Visual evaluation of the overall image quality was performed by two radiologists.
Results
Renal MRI at 7T was feasible in all eight subjects. Best image quality was found using T1-weighted gradient echo MRI, providing high anatomical details and excellent conspicuity of the non-enhanced vasculature. With successful shimming, B1 signal voids could be effectively reduced and/or shifted out of the region of interest in most sequence types. However, T2-weighted TSE imaging remained challenging and strongly impaired because of signal heterogeneities in three volunteers.
Conclusion
The results demonstrate the feasibility and diagnostic potential of dedicated 7T renal imaging. Further optimisation of imaging sequences and dedicated RF coil concepts are expected to improve the acquisition quality and ultimately provide high clinical diagnostic value.
Geld-zurück-Garantien erlangen in der Unternehmenspraxis eine immer größere Bedeutung, vor allem weil sie als probates Mittel zur Signalisierung hochwertiger Qualität angesehen werden – eine Annahme, die bislang wissenschaftlich ungeprüft geblieben ist. Vor diesem Hintergrund wird im vorliegenden Beitrag eine umfassende empirische Untersuchung der kaufverhaltensrelevanten Wirkungen dieses Marketinginstrumentes vorgenommen. Die Ergebnisse verdeutlichen zum einen, dass eine Geld-zurück-Garantie nur unter bestimmten Bedingungen als Qualitätssignal wirkt. Dies hängt neben der Art des Produktes (Erfahrungs- vs. Suchgut) insbesondere von der Ausprägung des für die Qualitätsbeurteilung besonders diagnostischen Merkmals Marke sowie von der Produktkenntnis der Konsumenten ab. Zum anderen zeigt sich aber auch, dass eine Geld-zurück-Garantie affektive Konsumentenreaktionen auslöst, die die Kaufabsicht von Konsumenten zusätzlich erhöhen können. Zusammenfassend stellen wir fest, dass eine Geld-zurück-Garantie – entgegen bisheriger Erwartungen aus der Praxis – nicht zwingend ein Qualitätsindikator ist, stattdessen entfaltet sie aber bisher unbeachtete affektive Wirkungen, die insbesondere auf ihre absichernde Funktion von etwaigen Fehlentscheidungen beim Kauf zurückzuführen sind.
A light-addressable potentiometric sensor (LAPS) can measure the concentration of one or several analytes at the sensor surface simultaneously in a spatially resolved manner. A modulated light pointer stimulates the semiconductor structure at the area of interest and a responding photocurrent can be read out. By simultaneous stimulation of several areas with light pointers of different modulation frequencies, the read out can be performed at the same time. With the new proposed controller electronic based on a field-programmable gate array (FPGA), it is possible to control the modulation frequencies, phase shifts, and light brightness of multiple light pointers independently and simultaneously. Thus, it is possible to investigate the frequency response of the sensor, and to examine the analyte concentration by the determination of the surface potential with the help of current/voltage curves and phase/voltage curves. Additionally, the ability to individually change the light intensities of each light pointer is used to perform signal correction.