Refine
Year of publication
Institute
- Fachbereich Energietechnik (1115) (remove)
Language
- English (588)
- German (524)
- Multiple languages (1)
- Dutch (1)
- Spanish (1)
Document Type
- Article (609)
- Conference Proceeding (259)
- Book (125)
- Part of a Book (84)
- Doctoral Thesis (10)
- Conference: Meeting Abstract (7)
- Report (7)
- Other (4)
- Talk (3)
- Diploma Thesis (2)
Keywords
- Blitzschutz (18)
- Lightning protection (11)
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Risikomanagement (4)
- Seismic design (4)
- reinforced concrete (4)
- Associated liquids (3)
Semi-insulating GaAs layers grown by molecular-beam epitaxy / P. Kordos ; A. Förster ; J. Betko ...
(1995)
Evaluation of dopant profiles and diffusion constants by means of electron energy loss spectroscopy
(1989)
Investigation of the InSb(110)-Sn schottky barrier by means of electron energy loss spectroscopy
(1987)
Die neue Welt
(1999)
Arsenic passivation of MOMBE grown GaAs surfaces / B. -J. Schäfer ; A. Förster ; M. Londschien ...
(1988)
The adsorption of fluor-carbon complexes on GaAs(110) studied by electron energy loss spectroscopy
(1986)
In the past, CSP and PV have been seen as competing technologies. Despite massive reductions in the electricity generation costs of CSP plants, PV power generation is - at least during sunshine hours - significantly cheaper. If electricity is required not only during the daytime, but around the clock, CSP with its inherent thermal energy storage gets an advantage in terms of LEC. There are a few examples of projects in which CSP plants and PV plants have been co-located, meaning that they feed into the same grid connection point and ideally optimize their operation strategy to yield an overall benefit. In the past eight years, TSK Flagsol has developed a plant concept, which merges both solar technologies into one highly Integrated CSP-PV-Hybrid (ICPH) power plant. Here, unlike in simply co-located concepts, as analyzed e.g. in [1] – [4], excess PV power that would have to be dumped is used in electric molten salt heaters to increase the storage temperature, improving storage and conversion efficiency. The authors demonstrate the electricity cost sensitivity to subsystem sizing for various market scenarios, and compare the resulting optimized ICPH plants with co-located hybrid plants. Independent of the three feed-in tariffs that have been assumed, the ICPH plant shows an electricity cost advantage of almost 20% while maintaining a high degree of flexibility in power dispatch as it is characteristic for CSP power plants. As all components of such an innovative concept are well proven, the system is ready for commercial market implementation. A first project is already contracted and in early engineering execution.
Mathematik PLuS als E-Book. Kann ein E-Book zur Ingenieursmathematik alle Lerntypen ansprechen?
(2017)
Die Erdbeben in Albstadt 1978 (Magnitude 5,7), Roermond 1992 (Magnitude 5,9) oder in Waldkirch 2004 (Magnitude 5,1) haben verdeutlicht, dass die erdbebensichere Auslegung von Mauerwerksbauten auch in Deutschland von großer Bedeutung ist. Bereits im Jahr 1981 wurde die DIN 4149 (1981) “Bauten in deutschen Erdbebengebieten – Lastannahmen, Bemessung und Ausführung üblicher Hochbauten“ eingeführt, in der aber für Mauerwerksbauten nur wenige Anforderungen gestellt wurden. Diese Norm wurde durch den NABau-Arbeitsausschuss “Erdbeben; Sonderfragen“ des Deutschen Instituts für Normung e.V. (DIN) auf Grundlage des Eurocode 8 (2004) vollständig überarbeitet und durch die DIN 4149 (2005) abgelöst, die umfangreiche Regelungen für die seismische Auslegung von Mauerwerksbauten enthält. Mittlerweile liegen die DIN EN 1998-1 (2010) und der Nationale Anhang DIN EN 1998-1/NA (2011) vor, die nach Einarbeitung der Ergebnisse der durchgeführten Anwendungserprobung bauaufsichtlich eingeführt und die DIN 4149 (2005) ersetzen werden. Der folgende Beitrag gibt einen Überblick über die seismische Berechnung und Bemessung von Mauerwerksbauten nach dem europäischen Regelwerk und illustriert deren Anwendung an einem baupraktischen Beispiel.