Refine
Year of publication
- 2024 (26)
- 2023 (40)
- 2022 (52)
- 2021 (56)
- 2020 (59)
- 2019 (71)
- 2018 (68)
- 2017 (67)
- 2016 (54)
- 2015 (70)
- 2014 (66)
- 2013 (65)
- 2012 (72)
- 2011 (82)
- 2010 (73)
- 2009 (85)
- 2008 (61)
- 2007 (57)
- 2006 (75)
- 2005 (48)
- 2004 (85)
- 2003 (57)
- 2002 (55)
- 2001 (54)
- 2000 (65)
- 1999 (40)
- 1998 (39)
- 1997 (36)
- 1996 (32)
- 1995 (19)
- 1994 (13)
- 1993 (19)
- 1992 (13)
- 1991 (12)
- 1990 (17)
- 1989 (21)
- 1988 (22)
- 1987 (26)
- 1986 (7)
- 1985 (10)
- 1984 (9)
- 1983 (6)
- 1982 (24)
- 1981 (16)
- 1980 (30)
- 1979 (20)
- 1978 (27)
- 1977 (13)
- 1976 (16)
- 1975 (14)
- 1974 (4)
- 1973 (3)
- 1972 (6)
- 1971 (1)
- 1969 (1)
- 1968 (2)
- 1967 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (2082) (remove)
Document Type
- Article (1596)
- Conference Proceeding (243)
- Book (97)
- Part of a Book (62)
- Doctoral Thesis (28)
- Patent (17)
- Report (15)
- Other (9)
- Habilitation (4)
- Lecture (3)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (16)
- CAD (15)
- civil engineering (14)
- Bauingenieurwesen (13)
- Einspielen <Werkstoff> (13)
- shakedown analysis (9)
- FEM (6)
- Limit analysis (6)
- Shakedown analysis (6)
High spin states in ¹³⁶ Ce
(1975)
High spin states in ¹³⁶ Ce
(1975)
In-beam study of ¹⁴⁴ Gd
(1978)
In-beam study of ¹⁴⁴ Gd
(1978)
In-beam study of ¹⁴⁴ Gd
(1977)
Isomeric states in ¹³⁴ Ba
(1980)
Isomeric states in ¹³⁴ Ba
(1980)
High-spin states in ¹³³ La
(1982)
High-spin states in ¹³³ La
(1980)
Isomeric state in ¹³⁴ La
(1981)
Isomeric state in ¹³⁶ La
(1981)
Band structure in ¹⁹⁴ Au
(1979)
High-spin states in ¹⁸⁰ Os
(1979)
High spin states in ¹⁸⁸ Au
(1982)
Side-bands in ¹⁸⁰ Os
(1981)
Yrast states up to spin 18 have been identified in ¹³²Ce. The energies and spins of the levels suggest the existence of two fairly well-behaved collective bands. The results are compared with those obtained in the rare-earth deformed region.
In-beam study of ¹⁴³ Eu
(1988)
Der konstruktive Entwurf wird in derzeitigen CAD-Systemen gut unterstützt, nicht aber der konzeptuelle Gebäude-Entwurf. Dieser abstrahiert von konstruktiven Elementen wie Linie, Wand oder Decke, um auf die Konzepte, d.h. die eigentlichen Funktionen, heraus zu arbeiten. Diese abstraktere, funktionale Sichtweise auf ein Gebäude ist während der frühen Entwurfsphase essentiell, um Struktur und Organisation des gesamten Gebäudes zu erfassen. Bereits in dieser Phase muss Fachwissen (z. B. rechtliche, ökonomische und technische Bestimmungen) berücksichtigt werden. Im Rahmen des vorliegenden Projekts werden Software-Werkzeuge integriert in industrielle CAD-Systeme entwickelt, die den konzeptuellen Gebäude-Entwurf ermöglichen und diesen gegen Fachwissen prüfen. Das Projekt ist in zwei Teile gegliedert. Im Top-Down-Ansatz werden Datenstrukturen und Methoden zur Strukturierung, Repräsentation und Evaluation von gebäudespezifischem Fachwissen erarbeitet. Dieser Teil baut auf den graphbasierten Werkzeugen PROGRES und UPGRADE des Lehrstuhls auf. Der Bottom-Up-Ansatz ist industriell orientiert und hat zum Ziel, das kommerzielle CAD-System ArchiCAD zu erweitern. Hierbei soll der frühe, konzeptuelle Gebäude-Entwurf in einem CAD-System ermöglicht werden. Der Entwurf kann darüber hinaus gegen das definierte Fachwissen geprüft werden. Im Rahmen des graphbasierten Top-Down-Ansatzes wurde zunächst eine neue Spezifikationsmethode für die Sprache PROGRES entwickelt. Das PROGRES-System erlaubt die Spezifikation von Werkzeugen in deklarativer Form. Üblicherweise wird domänenspezifisches Fachwissen in der PROGRES-Spezifikation codiert, das daraus generierte visuelle Werkzeug stellt dann die entsprechende Funktionalität zur Verfügung. Mit dieser Methode sind am Lehrstuhl für Informatik III Werkzeuge für verschie-dene Anwendungsdomänen entstanden. In unserem Fall versetzen wir einen Domänen-Experten, z. B. einen erfahrenen Architekten, in die Lage, Fachwissen zur Laufzeit einzugeben, dieses zu evaluieren, abzuändern oder zu ergänzen. Im Rahmen der bisherigen Arbeit wurde dazu eine parametrisierte PROGRES-Spezifikation und zwei darauf aufbauende Werkzeuge entwickelt, welche die dynamische Eingabe von gebäude-technisch relevantem Fachwissen erlauben und einen graphbasierten, konzeptuellen Gebäude-Entwurf ermöglichen. In diesem konzeptuellen Gebäude-Entwurf wird von Raumgrößen und Positionen abstrahiert, um die funktionale Struktur eines Gebäudes zu beschreiben. Das Fachwissen kann von einem Architekten visuell definiert werden. Es können semantische Einheiten, im einfachsten Fall Räume, nach verschiedenen Kriterien kategorisiert und klassifiziert werden. Mit Hilfe von Attributen und Relationen können die semantischen Einheiten präziser beschrieben und in Beziehung zueinander gesetzt werden. Die in PROGRES spezifizierten Konsistenz-Analysen erlauben die Prüfung eines graphbasierten konzeptuellen Gebäude-Entwurfs gegen das dynamisch eingefügte Fachwissen. Im zweiten Teil des Forschungsprojekts, dem Bottom-Up-Ansatz, wird das CAD-System ArchiCAD erweitert, um den integrierten konzeptuellen Gebäude-Entwurf zu ermöglichen. Der Architekt erhält dazu neue Entwurfselemente, die Raumobjekte, welche die relevanten semantischen Einheiten während der frühen Entwurfsphase repräsentieren. Mit Hilfe der Raumobjekte kann der Architekt in ArchiCAD den Grundriss und das Raumprogramm eines Gebäudes entwerfen, ohne von konstruktiven Details in seiner Kreativität eingeschränkt zu werden. Die Arbeitsweise mit Raumobjekten entspricht dem informellen konzeptuellen Entwurf auf einer Papierskizze und ist daher für den Architekten intuitiv und einfach zu verwenden. Durch die Integration in ArchiCAD ergibt sich eine weitere Unterstützung: Das im Top-Down-Ansatz spezifizierte Fach-wissen wird verwendet, um den konzeptuellen Gebäude-Entwurf des Architekten auf Regelverletzungen zu überprüfen. Entwurfsfehler werden angezeigt. Zum Abschluss des konzeptuellen Gebäude-Entwurfs mit Raumobjekten wird durch ein weiteres neu entwickeltes Werkzeug eine initiale Wandstruktur automatisch erzeugt, die als Grundlage für die folgenden konstruktiven Entwurfsphasen dient. Alle beschriebenen Erwei-terungen sind in ArchiCAD integriert, sie sind für den Architekten daher leicht zu erlernen und einfach zu bedienen.
Aneurysmal subarachnoid hemorrhage (aSAH) is associated with early and delayed brain injury due to several underlying and interrelated processes, which include inflammation, oxidative stress, endothelial, and neuronal apoptosis. Treatment with melatonin, a cytoprotective neurohormone with anti-inflammatory, anti-oxidant and anti-apoptotic effects, has been shown to attenuate early brain injury (EBI) and to prevent delayed cerebral vasospasm in experimental aSAH models. Less is known about the role of endogenous melatonin for aSAH outcome and how its production is altered by the pathophysiological cascades initiated during EBI. In the present observational study, we analyzed changes in melatonin levels during the first three weeks after aSAH.
We investigate the suitability of selected measures of complexity based on recurrence quantification analysis and recurrence networks for an identification of pre-seizure states in multi-day, multi-channel, invasive electroencephalographic recordings from five epilepsy patients. We employ several statistical techniques to avoid spurious findings due to various influencing factors and due to multiple comparisons and observe precursory structures in three patients. Our findings indicate a high congruence among measures in identifying seizure precursors and emphasize the current notion of seizure generation in large-scale epileptic networks. A final judgment of the suitability for field studies, however, requires evaluation on a larger database.
Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs
(2012)
The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines.
This paper presents a novel numerical procedure for computing limit and shakedown loads of structures using a node-based smoothed FEM in combination with a primal–dual algorithm. An associated primal–dual form based on the von Mises yield criterion is adopted. The primal-dual algorithm together with a Newton-like iteration are then used to solve this associated primal–dual form to determine simultaneously both approximate upper and quasi-lower bounds of the plastic collapse limit and the shakedown limit. The present formulation uses only linear approximations and its implementation into finite element programs is quite simple. Several numerical examples are given to show the reliability, accuracy, and generality of the present formulation compared with other available methods.
Temperature-dependent ranges of coexistence in a model of a two-prey-one-predator microbial food web
(2012)
The objective of our study was to analyze the effects of temperature on the population dynamics of a three-species food web consisting of two prey bacteria (Pedobacter sp. and Acinetobacter johnsonii) and a protozoan predator (Tetrahymena pyriformis) as model organisms. We assessed the effects of temperature on the growth rates of all three species with the objective of developing a model with four differential equations based on the experimental data. The following hypotheses were tested at a theoretical level: Firstly, temperature changes can affect the dynamic behavior of a system by temperature-dependent parameters and interactions and secondly, food web response to temperature cannot be derived from the single species temperature response. The main outcome of the study is that temperature changes affect the parameter range where coexistence is possible within all three species. This has significant consequences on our ideas regarding the evaluation of effects of global warming.
The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge.
An H2O2 sensor for the application in industrial sterilisation processes has been developed. Therefore, automated sterilisation equipment at laboratory scale has been constructed using parts from industrial sterilisation facilities. In addition, a software tool has been developed for the control of the sterilisation equipment at laboratory scale. First measurements with the developed sensor set-up as part of the sterilisation equipment have been performed and the sensor has been physically characterised by optical microscopy and SEM.
The absence of a general method for endotoxin removal from liquid interfaces gives an opportunity to find new methods and materials to overcome this gap. Activated nanostructured carbon is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study is to find the adsorption rates for a carboneous material produced at different temperatures, as well as to reveal possible differences between the performance of the material for each of the adsorbates used during the study (hemoglobin, serum albumin and lipopolysaccharide, LPS).
Sterilisation processes are compulsory in medicine, pharmacy, and food industries to prevent infections of consumers and microbiological contaminations of products. Monitoring the sterilisation by conventional microbiological methods is time- and lab-consuming. To overcome this problem, in this work a novel biosensor has been proposed. The sensor enables a fast method to evaluate sterilisation processes. By means of thin-film technology the sensor's transducer structures in form of IDEs (interdigitated electrodes) have been fabricated on a silicon substrate. Physical characterisation of the developed sensor was done by AFM, SEM, and profilometry. Impedance analyses were conducted for the electrical characterisation. As microbiological layer spores of B. atrophaeus have been immobilised on the sensing structure; spores of this type are a well-known sterilisation test organism. Impedance measurements at a fixed frequency over time were performed to monitor the immobilisation process. A sterilisation process according to aseptic filling machines was applied to demonstrate the sensor functionality. After both, immobilisation and sterilisation, a change in impedance could successfully be detected.
In this work, a sensor to evaluate sterilization processes with hydrogen peroxide vapor has been characterized. Experimental, analytical and numerical methods were applied to evaluate and study the sensor behavior. The sensor set-up is based on planar interdigitated electrodes. The interdigitated electrode structure consists of 614 electrode fingers spanning over a total sensing area of 20 mm2. Sensor measurements were conducted with and without microbiological spores as well as after an industrial sterilization protocol. The measurements were verified using an analytical expression based on a first-order elliptical integral. A model based on the finite element method with periodic boundary conditions in two dimensions was developed and utilized to validate the experimental findings.
In this work, the catalyst manganese(IV) oxide (MnO2), of calorimetric gas sensors (to monitor the sterilization agent vaporized hydrogen peroxide) has been investigated in more detail. Chemical analyses by means of X-ray-induced photoelectron spectroscopy have been performed to unravel the surface chemistry prior and after exposure to hydrogen peroxide vapor at elevated temperature, as applied in the sterilization processes of beverage cartons. The surface characterization reveals a change in oxidation states of the metal oxide catalyst after exposure to hydrogen peroxide. Additionally, a cleaning effect of the catalyst, which itself is attached to the sensor surface by means of a polymer interlayer, could be observed.
The sterilization of packages in aseptic food processes is highly significant to maintain a consumer-safe product with extended shelf-life. Today, the sterilization of food packages is predominantly accomplished by gaseous hydrogen peroxide (H2O2) in combination with heat. In order to monitor this sterilization process, calorimetric gas sensors as differential set-up of two platinum temperature sensors representing a catalytically active (additionally deposition of MnO2) and a passive segment have been recently developed. The temperature rise of the exothermic decomposition serves as an indicator of the present H2O2 concentration. In the present work, a theoretical approach considering the sensor’s thermochemistry and physical transport phenomena was formulated to evaluate the temperature rise based on the energy content of gaseous H2O2. In a further part of this work, three polymers have been analyzed with respect to their application as passivation materials. The examined polymers are photoresist SU-8, perfluoroalkoxy (PFA) and fluorinated ethylene propylene (FEP). Thermal analyses by means of differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) have been conducted to determine the operation limits of the polymers. The overall chemical resistance and stability of the polymers against the harsh environmental conditions during the sterilization process have been examined by attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR).
In this work, a spore-based biosensor is evaluated to monitor the microbicidal efficacy of sterilization processes applying gaseous hydrogen peroxide (H2O2). The sensor is based on interdigitated electrode structures (IDEs) that have been fabricated by means of thin-film technologies. Impedimetric measurements are applied to study the effect of sterilization process on spores of Bacillus atrophaeus. This resilient microorganism is commonly used in industry to proof the sterilization efficiency. The sensor measurements are accompanied by conventional microbiological challenge tests, as well as morphological characterizations with scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The sensor measurements are correlated with the microbiological test routines. In both methods, namely the sensor-based and microbiological one, a tailing effect has been observed. The results are evaluated and discussed in a three-dimensional calibration plot demonstrating the sensor's suitability to enable a rapid process decision in terms of a successfully performed sterilization.
Entwicklung eines Prototypen zur Prognose von Frühgeburten : ein biomedizintechnischer Ansatz
(2012)
In positron emission tomography improving time, energy and spatial detector resolutions and using Compton kinematics introduces the possibility to reconstruct a radioactivity distribution image from scatter coincidences, thereby enhancing image quality. The number of single scattered coincidences alone is in the same order of magnitude as true coincidences. In this work, a compact Compton camera module based on monolithic scintillation material is investigated as a detector ring module. The detector interactions are simulated with Monte Carlo package GATE. The scattering angle inside the tissue is derived from the energy of the scattered photon, which results in a set of possible scattering trajectories or broken line of response. The Compton kinematics collimation reduces the number of solutions. Additionally, the time of flight information helps localize the position of the annihilation. One of the questions of this investigation is related to how the energy, spatial and temporal resolutions help confine the possible annihilation volume. A comparison of currently technically feasible detector resolutions (under laboratory conditions) demonstrates the influence on this annihilation volume and shows that energy and coincidence time resolution have a significant impact. An enhancement of the latter from 400 ps to 100 ps leads to a smaller annihilation volume of around 50%, while a change of the energy resolution in the absorber layer from 12% to 4.5% results in a reduction of 60%. The inclusion of single tissue-scattered data has the potential to increase the sensitivity of a scanner by a factor of 2 to 3 times. The concept can be further optimized and extended for multiple scatter coincidences and subsequently validated by a reconstruction algorithm.
A new functionalization method to modify capacitive electrolyte–insulator–semiconductor (EIS) structures with nanofilms is presented. Layers of polyallylamine hydrochloride (PAH) and graphene oxide (GO) with the compound polyaniline:poly(2-acrylamido-2-methyl-1-propanesulfonic acid) (PANI:PAAMPSA) are deposited onto a p-Si/SiO2 chip using the layer-by-layer technique (LbL). Two different enzymes (urease and penicillinase) are separately immobilized on top of a five-bilayer stack of the PAH:GO/PANI:PAAMPSA-modified EIS chip, forming a biosensor for detection of urea and penicillin, respectively. Electrochemical characterization is performed by constant capacitance (ConCap) measurements, and the film morphology is characterized by atomic force microscopy (AFM) and scanning electron microscopy (SEM). An increase in the average sensitivity of the modified biosensors (EIS–nanofilm–enzyme) of around 15% is found in relation to sensors, only carrying the enzyme but without the nanofilm (EIS–enzyme). In this sense, the nanofilm acts as a stable bioreceptor onto the EIS chip improving the output signal in terms of sensitivity and stability.
Purpose: Impaired paravascular drainage of β-Amyloid (Aβ) has been proposed as a contributing cause for sporadic Alzheimer’s disease (AD), as decreased cerebral blood vessel pulsatility and subsequently reduced propulsion in this pathway could lead to the accumulation and deposition of Aβ in the brain. Therefore, we hypothesized that there is an increased impairment in pulsatility across AD spectrum.
Patients and Methods: Using transcranial color-coded duplex sonography (TCCS) the resistance and pulsatility index (RI; PI) of the middle cerebral artery (MCA) in healthy controls (HC, n=14) and patients with AD dementia (ADD, n=12) were measured. In a second step, we extended the sample by adding patients with mild cognitive impairment (MCI) stratified by the presence (MCI-AD, n=8) or absence of biomarkers (MCI-nonAD, n=8) indicative for underlying AD pathology, and compared RI and PI across the groups. To control for atherosclerosis as a confounder, we measured the arteriolar-venular-ratio of retinal vessels.
Results: Left and right RI (p=0.020; p=0.027) and left PI (p=0.034) differed between HC and ADD controlled for atherosclerosis with AUCs of 0.776, 0.763, and 0.718, respectively. The RI and PI of MCI-AD tended towards ADD, of MCI-nonAD towards HC, respectively. RIs and PIs were associated with disease severity (p=0.010, p=0.023).
Conclusion: Our results strengthen the hypothesis that impaired pulsatility could cause impaired amyloid clearance from the brain and thereby might contribute to the development of AD. However, further studies considering other factors possibly influencing amyloid clearance as well as larger sample sizes are needed.
In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit.
Für die Approximation stetiger, 2π-periodischer Funktionen auf der reellen Achse durch trigonometrische Polynome wurde ein direkter Satz von D. Jackson 1911 [8] und die Umkehrung von S. N. Bernstein 1912 [1] bewiesen und die Ergebnisse von A. Zygmund [25] 1945 verallgemeinert. 1949 stellte M. Zamansky [25] eine Beziehung zwischen der Approximationsordnung und dem Wachstum bezϋglich n der Ableitungen der Approximationspolynome her; auf die Approximationsordnung für die Ableitungen der Funktion schloβ S. B. Steckin 1951.
Die Umkehrung des Ergebnisses von M. Zamansky bewies G. Sunouchi 1968 [21,22], womit die Aquivalenz aller Aussagen gezeigt ist.
Die Übertragung der Ergebnisse auf Approximationsoperatoren in Banachräumen stammt von K. Scherer und P. L. Butzer [3, 4], wobei gewisse Voraussetzungen an die Operatorfolge (eine verallgemeinerte Bernsteinsche Ungleichung und eine sogenannte Jacksonsche Ungleichung) gestellt werden. An die Stelle der strukturellen Eigenschaften der Funktion, die durch das Verhalten des Stetigkeitsmoduls der Funktion charakterisiert werden, treten in allgemeinen Banachräumen Eigenschaften des von J. Peetre [17] eingefϋhrten K-Funktionals.
In dieser Arbeit wird die Approximation von Funktionen, die auf der Einheitskugel Sᵏ im Rᵏ definiert sind, durch Linearkombinationen von Kugelfunktionen untersucht. Es wird für diesen Fall eine Bernstein-Ungleichung und die Jackson-Ungleichung bewiesen, wenn man die Ableitung durch den Laplace-Operator auf Sᵏ ersetzt. Damit ist der oben zitierte allgemeine Satz von Butzer-Scherer anwendbar. Weiter kann man hier an Stelle des K-Funktionals einen verallgemeinerten Stetigkeitsmodul setzen. Anschlieβend wird der Spezialfall der zonalen Funktionen und ihre Approximation durch algebraische Polynome untersucht.
Limitierungsverfahren von Reihen mehrdimensionaler Kugelfunktionen und deren Saturationsverhalten
(1968)
Die vorliegende Arbeit untersucht das approximationstheoretische Verhalten von Summationsprozessen von Reihen von Kugelfunktionen, sogenannten Laplace-Reihen. Zunächst wird die Theorie der besten Approximation auf der Kugel, also die Erweiterung der Sätze von D. Jackson und S. Bernstein, skizziert. Nimmt man nun spezielle Verfahren zur Summation von Laplace-Reihen, dann lassen sich auch hier Sätze vom Jacksonschen und Bernsteinschen Typ beweisen. Darüber hinaus zeigen viele Verfahren ein Saturationsverhalten, d.h. es gibt eine nur vom Verfahren abhängige optimale Approximationsordnung. Das Saturationsproblem besteht nun darin, diejenige Klasse von Funktionen (Saturationsklasse) zu bestimmen, welche genau von der optimalen Ordnung approximiert werden.
Metathese von Ölsäure und Derivaten ist ein interessanter Weg für die Synthese bifunktioneller Verbindungen aus nachwachsenden Rohstoffen. Verwendet wurden Ru-Katalysatoren der zweiten Generation, welche eine hohe Toleranz gegenüber funktionellen Gruppen und Verunreinigungen aufweisen. Trotz des Einsatzes technischer Edukte waren Umsetzungen mit niedrigen Katalysatormengen (0.001 – 0.01 mol-%) möglich, mit Ausbeuten entsprechend der Literatur. Kreuzmetathesen ermöglichten variable Kettenlängen und Funktionalitäten der Monomere, die Produktgewinnung ist jedoch aufwändig. Selbstmetathese lieferte C18-bifunktionelle Verbindungen, welche einfach durch Destillation oder Kristallisation isoliert werden können. Neben der katalystischen Umsetzung wurde auch die Produktgewinnung untersucht und für ausgewählte Produkte auch im größeren Maßstab durchgeführt.
This paper develops a new finite element method (FEM)-based upper bound algorithm for limit and shakedown analysis of hardening structures by a direct plasticity method. The hardening model is a simple two-surface model of plasticity with a fixed bounding surface. The initial yield surface can translate inside the bounding surface, and it is bounded by one of the two equivalent conditions: (1) it always stays inside the bounding surface or (2) its centre cannot move outside the back-stress surface. The algorithm gives an effective tool to analyze the problems with a very high number of degree of freedom. Our numerical results are very close to the analytical solutions and numerical solutions in literature.
Image reconstruction analysis for positron emission tomography with heterostructured scintillators
(2022)
The concept of structure engineering has been proposed for exploring the next generation of radiation detectors with improved performance. A TOF-PET geometry with heterostructured scintillators with a pixel size of 3.0×3.1×15 mm3 was simulated using Monte Carlo. The heterostructures consisted of alternating layers of BGO as a dense material with high stopping power and plastic (EJ232) as a fast light emitter. The detector time resolution was calculated as a function of the deposited and shared energy in both materials on an event-by-event basis. While sensitivity was reduced to 32% for 100 μm thick plastic layers and 52% for 50 μm, the CTR distribution improved to 204±49 ps and 220±41 ps respectively, compared to 276 ps that we considered for bulk BGO. The complex distribution of timing resolutions was accounted for in the reconstruction. We divided the events into three groups based on their CTR and modeled them with different Gaussian TOF kernels. On a NEMA IQ phantom, the heterostructures had better contrast recovery in early iterations. On the other hand, BGO achieved a better contrast to noise ratio (CNR) after the 15th iteration due to the higher sensitivity. The developed simulation and reconstruction methods constitute new tools for evaluating different detector designs with complex time responses.