Refine
Year of publication
- 2003 (254) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (57)
- Fachbereich Elektrotechnik und Informationstechnik (33)
- Fachbereich Maschinenbau und Mechatronik (31)
- Fachbereich Wirtschaftswissenschaften (31)
- INB - Institut für Nano- und Biotechnologien (30)
- Fachbereich Energietechnik (25)
- IfB - Institut für Bioengineering (24)
- Fachbereich Luft- und Raumfahrttechnik (21)
- Fachbereich Bauingenieurwesen (20)
- Fachbereich Chemie und Biotechnologie (14)
Language
- German (147)
- English (106)
- Portuguese (1)
Document Type
- Article (154)
- Conference Proceeding (40)
- Book (29)
- Part of a Book (11)
- Course Material (7)
- Patent (5)
- Part of a Periodical (3)
- Other (2)
- Doctoral Thesis (1)
- Report (1)
Keywords
- Blitzschutz (6)
- Lightning protection (6)
- CAD (4)
- Clusterion (4)
- Air purification (3)
- Auslenkung (3)
- Bauingenieurwesen (3)
- Fachhochschule Aachen (3)
- Javasimulation (3)
- Luftreiniger (3)
Forschung & Lehre Fachhochschule Aachen auf der IAA 2003 Zehn Studenten der Fachhochschule Aachen entwickeln neue Landschaftsmöbel Erfolgreiche Forschung am Lehrgebiet Hoch- und Höchstfrequenztechnik Studiengänge MBA Studiengang „Entrepreneurship“ in Düren nun bald mit Qualitätssiegel Der neue Studiengang Communication and Multimediadesign beginnt Internationales Lehr- und Forschungsnetz der FH spannt sich bis nach Florida Wissenschaftler der FH Aachen „Down-Under“ sehr gefragt FH-Service Auf dem Weg zur Marke – Die FH präsentiert ihre neuen Produkte Die Weiterbildung „UmBau“ und der Gerling-Pavillon in Jülich Drei starke Partner ein Link: Die „AachenJuelichBib“ Personen Personalinfo Seit 30 Jahren im „Sattel“ – Dienstjubiläum von Reiner Smeetz Neuer stellvertretender Bibliotheksleiter Klaus-Dieter Thormann
Editorial Bioengineering – Schulterschluss von Ingenieuren und Naturwissenschaftlern Die Life Sciences der Region Aachen-Jülich zwischen „Bio-River“ und dem „Life Science Triangle Maas/Rhein“ Cellularengineering – Was suchen Ingenieure in der Biologie? Zukunftswerkstatt Biosensorik Pharmakogenetik- Wie man mit Hilfe der eigenen Gene die wirksamsten Medikamente findet Kultivierung blutbildender Zellen im Bioreaktor Kunststoffpartikel in Medizin und Biotechnologie Automotive Engineering. Der Wettlauf um das andere Auto car e.V. – Das unabhängige Competence Center der Automobiltechnik Motorentechnologien der Zukunft Die Fahrzeugkarosserie von morgen Simulation mechatronischer Systeme im Automobil Gezielte Entwicklung von Fahrwerkskomponenten mit Hilfe moderner Berechnungsverfahren Hochtechnologie in der KFZ-Restauration Akustikwindkanal für DaimlerChrysler/USA Technology gegen Ton im Auto-Design Podiumsdiskussion „Physiotherapie-Studium künftig auch in Nordrehin-Westfalen an Fachhochschulen?“ Förderung von Unternehmen und Hochschulen im Doppelpack – „PROgramm INNOvationskompetenz mittelständischer Unternehmen“ (PRO INNO) der AiF Diskussionsrunde zum Thema „Ingenieurstudium – Lohnt sich das?“ Globalisierung – Ist die Welt noch zu retten? Expertenrunde zum Thema „Stammzellenforschung – Möglichkeiten und Grenzen“ Kontaktmesse im Foyer Begleitprogramm Sponsoren
A explicação do conceito científico de Gestão de competências mostra o valor de desenvolvimento dos subordinarios. Ferramentas práticas explicam o conceito através de experiências de empresas européias. As Competência sao os seguintes: Competência especializada, Competência Metódica, Competência social, Competência individual.
Cement augmentation is an emerging surgical procedure in which bone cement is used to infiltrate and reinforce osteoporotic vertebrae. Although this infiltration procedure has been widely applied, it is performed empirically and little is known about the flow characteristics of cement during the injection process. We present a theoretical and experimental approach to investigate the intertrabecular bone permeability during the infiltration procedure. The cement permeability was considered to be dependent on time, bone porosity, and cement viscosity in our analysis. In order to determine the time-dependent permeability, ten cancellous bone cores were harvested from osteoporotic vertebrae, infiltrated with acrylic cement at a constant flow rate, and the pressure drop across the cores during the infiltration was measured. The viscosity dependence of the permeability was determined based on published experimental data. The theoretical model for the permeability as a function of bone porosity and time was then fit to the testing data. Our findings suggest that the intertrabecular bone permeability depends strongly on time. For instance, the initial permeability (60.89 mm4/N.s) reduced to approximately 63% of its original value within 18 seconds. This study is the first to analyze cement flow through osteoporotic bone. The theoretical and experimental models provided in this paper are generic. Thus, they can be used to systematically study and optimize the infiltration process for clinical practice.
Härtebegriff im Zusammenhang mit Vernetzung, Bruchdehnung und Dauerfestigkeit eines Elastomers
(2003)
Innovationsforschung heute : die Mannheimer Innovationspanels / Norbert Janz ; Georg Licht (Hrsg.)
(2003)
Layer Deposition I
(2003)
Mauerwerksbauten
(2003)
Mobile CRM-Systeme : Customer Relationship Management zur Unterstützung des Vertriebsaußendienstes
(2003)
Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems.
(2003)
Recently, SHARP corporation has developed the world’s first “Plasma Cluster Ions (PCI)” air purification technology, which uses plasma discharge to generate cluster ions. The new plasma cluster device releases into the air positive and negative ions, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. A lot of phenomenological tests of the PCI air purification technology on microbial cells have been conducted. And, in most cases, it has been shown that PCI demonstrate strongly pronounced killing effect. Although, the particular mechanisms of PCI action are still not evident. We studied variations in resistance to PCI among gram-positive airborne microorganisms, as well as some dose-dependent, spatial, cultural and biochemical properties of PCI action in respect of Staphylococcus spp, Enterococcus spp, Micrococcus spp.
Recently, SHARP corporation has developed the world’s first "Plasma Cluster Ions® (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new Plasma Cluster Device releases positive and negative ions into the air, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. In the past, phenomenological tests on the efficacy of the PCI air purification technology on microbial cells have been conducted. In most cases, it has been shown that PCI demonstrated strongly pronounced killing effects on microorganisms. However, the particular mechanisms of PCI action still have to be uncovered.
Production and distribution of personalized information services employing mass customization
(2003)
Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET
(2003)
A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time.
Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET
(2003)
A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time.
Rapid Prototyping
(2003)
Rechtsfolgen vorbehaltloser Mietzahlung in Mangelkenntnis –Mehr als bloß eine Etappe beim BGH?
(2003)
Ein vorausschauendes Risikomanagement beinhaltet, Risiken zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent,welche Risiken sinnvoll über Versicherungen abgedeckt werden sollten. Bei Unternehmen, die mit umfangreichen elektronischenEinrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nichtverfügbarkeit der elektronischen Einrichtungen und damit derProduktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardwareschaden an der betroffenen Anlage oft bei weitem übersteigt.
Die neue Vornorm VDE V 0185 Teil 2 „Risikomanagement: Abschätzung des Schadensrisikos für bauliche Anlagen“ [1] ist seit November 2002 gültig. Sie ermöglicht nicht nur die Ermittlung der Schutzklasse eines Blitzschutzsystems, sondern auch die Untersuchung zur Notwendigkeit anderer Schutzmaßnahmen gegen Blitzeinwirkungen (Überspannungsschutzgeräte in Unterverteilern und/oder an Endgeräten, Schirmung des Gebäudes und/oder interner Räume, Potentialsteuerung, Brandmelde- und Feuerlöscheinrichtungen, etc.) nach objektiven Kriterien und damit in einer für alle Beteiligten grundsätzlich nachvollziehbaren Art und Weise. Dass eine solche Analyse rel. komplex sein muss und der intensiven Beschäftigung bedarf, ist deshalb nicht verwunderlich. Die Komplexität des Verfahrens sollte allerdings nicht dazu führen, die Vornorm als Ganzes abzulehnen. Die Vornorm beruht auf dem Stand der Diskussion im internationalen Normengremium IEC TC81 WG9 Ende des Jahres 2000. Integriert wurden einige nationale Besonderheiten, die aus Sicht des zuständigen Normenkomitees DKE K251 erforderlich erschienen. In Deutschland konnten und können nun erste breite Erfahrungen in der Anwendung dieser Risikoanalyse gesammelt werden; in anderen Ländern ist dies noch nicht möglich. Diese Erfahrungen können dann, nach Diskussion im nationalen Rahmen, in die internationale Normenarbeit eingebracht werden. Im folgenden Beitrag sollen einige, seit Erscheinen der Vornorm oft wiederkehrende Fragen dargestellt und Lösungsvorschläge vorgestellt werden. Dabei wird auch auf die Tendenzen im internationalen Normengremium IEC TC81 WG9 eingegangen, d.h. auf den aktuellen Entwurf zur IEC 62305-2 [3]. Die Lösungsvorschläge werden begründet, sind allerdings weitestgehend subjektive Meinung des Autors. Für übliche bauliche Anlagen ist die Anwendung der Vornorm rel. einfach möglich. Auch für spezielle Fälle können die darin festgelegten Verfahren herangezogen werden; allerdings sind dann einige weiterführende Überlegungen notwendig, die der Planer von Blitzschutzsystemen durchführen muss. Anhand zweier Beispiele soll die Anwendung der VDE V 0185 Teil 2 auf solche speziellen Fälle dargestellt werden.