Article
Refine
Year of publication
- 2003 (154) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (39)
- INB - Institut für Nano- und Biotechnologien (27)
- Fachbereich Wirtschaftswissenschaften (25)
- Fachbereich Maschinenbau und Mechatronik (17)
- IfB - Institut für Bioengineering (15)
- Fachbereich Elektrotechnik und Informationstechnik (14)
- Fachbereich Bauingenieurwesen (13)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Energietechnik (12)
- Fachbereich Chemie und Biotechnologie (8)
Document Type
- Article (154) (remove)
Keywords
- Blitzschutz (2)
- Lightning protection (2)
- Alternative Energiequelle (1)
- Analysis (1)
- Architektur (1)
- Bauingenieurwesen (1)
- CAD (1)
- Cement infiltration (1)
- Digital Museum (1)
- Digitales Museum (1)
Sanierung des ehemaligen Gaswerkgeländes am Bremer Hauptbahnhof / K. Konertz ; E. Biener ; T. Sasse
(2003)
Strategies of miniaturised reference electrodes integrated in a silicon-based „one chip“ pH sensor
(2003)
Härtebegriff im Zusammenhang mit Vernetzung, Bruchdehnung und Dauerfestigkeit eines Elastomers
(2003)
Layer Deposition I
(2003)
Sonderbilanz und Status
(2003)
Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET
(2003)
A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time.
Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET
(2003)
A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time.
Untersuchung eines hybriden EMV-Simulationsverfahrens anhand eines virtuellen Komponententests
(2003)
Structural design analyses are conducted with the aim of verifying the exclusion of ratchetting. To this end it is important to make a clear distinction between the shakedown range and the ratchetting range. The performed experiment comprised a hollow tension specimen which was subjected to alternating axial forces, superimposed with constant moments. First, a series of uniaxial tests has been carried out in order to calibrate a bounded kinematic hardening rule. The load parameters have been selected on the basis of previous shakedown analyses with the PERMAS code using a kinematic hardening material model. It is shown that this shakedown analysis gives reasonable agreement between the experimental and the numerical results. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis.
Mobile CRM-Systeme : Customer Relationship Management zur Unterstützung des Vertriebsaußendienstes
(2003)
Solar sailcraft of the first generation technology development / Seboldt, Wolfgang ; Dachwald, Bernd
(2003)
Application of a (bio-)chemical sensor (ISFET) for the detection of physical parameters in liquids
(2003)
Das von Texas-Instruments (TI) vertriebene Interface CBL2 wird über einige TI-Grafik-Rechner (TI-92, TI-89 usw.) angesteuert. Wegen seiner Handlichkeit wird dieses System beim Unterricht in wechselnden Räumen »großen« Messwerterfassungssystemen oft vorgezogen. Das CBL2 bietet drei analoge Eingänge, die immerhin mit 10 Bit Auflösung und bis zu einer Frequenz von 50 kHz arbeiten. Weiterhin besitzt das CBL2 eine Buchse für angeblich nur einen digitalen Ein- bzw. Ausgang. An diesem Eingang wird standardmäßig hauptsächlich der Bewegungssensor CBR betrieben. In diesem Beitrag werden Erweiterungsmöglichkeiten dieses Anschlusses beschrieben.
Kunstwerke sowie ihre Präsentation und Vermittlung werden zunehmend von digitalen Technologien unterstützt. Virtuelle Ausstellungen, Internet-Projekte und komplexe Datenarchive stellen das Kunstwerk in einen medialen Kontext, der weit über das Moment einer technischen Reproduzierbarkeit hinausgeht. Das allgegenwärtige Konzept der Vernetzung dynamisiert Kunst, ihre Rezipienten und Ausstellungsorte. Die Beziehungen zwischen diesen Feldern werden mit Hilfe physiologischer Metaphern definiert und visualisiert. Frühere Speicher und Archive geraten in einen prozessualen Sog, in dem alles fluktuiert, sich kurzweilig verknüpft, auflöst und in permanente Dialoge mit seiner Umgebung tritt - das virtuelle Museum gerät in aktuellen Standortbestimmungen in die definitorische Nähe des Künstlichen Lebens.