Refine
Year of publication
- 2005 (48) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (48) (remove)
Document Type
- Article (40)
- Conference Proceeding (4)
- Book (3)
- Other (1)
Keywords
- Bauingenieurwesen (3)
- CAD (3)
- civil engineering (3)
- Alternating plasticity (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Deformation (1)
- Design-by-analysis (1)
- Einspiel-Analyse (1)
- Einspiel-Kriterium (1)
- Einspielen <Werkstoff> (1)
- FEM (1)
- Finite-Elemente-Methode (1)
- Global and local collapse (1)
- Grenzwertberechnung (1)
- Limit analysis (1)
- Plastizität (1)
- Pressure loaded crack-face (1)
- Progressive plastic deformation (1)
- Shakedown analysis (1)
- Shakedown criterion (1)
- Traglastanalyse (1)
- alternierend Verformbarkeit (1)
- fortschreitende plastische Deformation (1)
The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner
(2005)
Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view.
Preliminary data shows a correct identification of the crystal layer about (98±1)%. Typically the energy resolution is (23.3±0.5)% for the luyap layer and (15.4±0.4)% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled.
The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it.
Limit loads can be calculated with the finite element method (FEM) for any component, defect geometry, and loading. FEM suggests that published long crack limit formulae for axial defects under-estimate the burst pressure for internal surface defects in thick pipes while limit loads are not conservative for deep cracks and for pressure loaded crack-faces. Very deep cracks have a residual strength, which is modelled by a global collapse load. These observations are combined to derive new analytical local and global collapse loads. The global collapse loads are close to FEM limit analyses for all crack dimensions.
In the new European standard for unfired pressure vessels, EN 13445-3, there are two approaches for carrying out a Design-by-Analysis that cover both the stress categorization method (Annex C) and the direct route method (Annex B) for a check against global plastic deformation and against progressive plastic deformation. This paper presents the direct route in the language of limit and shakedown analysis. This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for mechanical and thermal actions. One observation from the examples is that the so-called 3f (3Sm) criterion fails to be a reliable check against progressive plastic deformation. Precise conditions are given, which greatly restrict the applicability of the 3f criterion.
Miniaturised reference electrodes for field-effect sensors compatible to silicon chip technology
(2005)
468 Scatter dose determination at the eye lens during a mask based whole brain radiotherapy (WBRT)
(2005)
Mit Logik die Welt begreifen
(2005)
Proc. of the 2005 ASCE Intl. Conf. on Computing in Civil Engineering (ICCC 2005) eds. L. Soibelman und F. Pena-Mora, Seite 1-14, ASCE (CD-ROM), Cancun, Mexico, 2005 Current CAD tools are not able to support the fundamental conceptual design phase, and none of them provides consistency analyses of sketches produced by architects. To give architects a greater support at the conceptual design phase, we develop a CAD tool for conceptual design and a knowledge specification tool allowing the definition of conceptually relevant knowledge. The knowledge is specific to one class of buildings and can be reused. Based on a dynamic knowledge model, different types of design rules formalize the knowledge in a graph-based realization. An expressive visual language provides a user-friendly, human readable representation. Finally, consistency analyses enable conceptual designs to be checked against this defined knowledge. In this paper we concentrate on the knowledge specification part of our project.
In: Computer Aided Architectural Design Futures 2005 2005, Part 4, 207-216, DOI: http://dx.doi.org/10.1007/1-4020-3698-1_19 The conceptual design at the beginning of the building construction process is essential for the success of a building project. Even if some CAD tools allow elaborating conceptual sketches, they rather focus on the shape of the building elements and not on their functionality. We introduce semantic roomobjects and roomlinks, by way of example to the CAD tool ArchiCAD. These extensions provide a basis for specifying the organisation and functionality of a building and free architects being forced to directly produce detailed constructive sketches. Furthermore, we introduce consistency analyses of the conceptual sketch, based on an ontology containing conceptual relevant knowledge, specific to one class of buildings.
In: Forum Bauinformatik 2005 : junge Wissenschaftler forschen / [Lehrstuhl Bauinformatik, Brandenburgische Technische Universität Cottbus. Frank Schley ... (Hrsg.)]. - Cottbus : Techn. Universität 2005. S. 1-10 ISBN 3-934934-11-0
Mittels eines operationalen Ansatzes zur Semantikdefinition wird am Bei-spiel des konzeptuellen Gebäudeentwurfs ein Regelsystem formalisiert. Dazu werdenzwei Teile, zum einen das Regelwissen, zum anderen ein konzeptueller Entwurfsplan zunächst informell eingeführt und dann formal beschrieben. Darauf aufbauend wird die Grundlage für eine Konsistenzprüfung des konzeptuellen Entwurfs gegen das Regel-wissen formal angeben
This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.
Flow visualization by means of PIV of an artificial aortic heart valve fixed into a mock aorta
(2005)
After a short introduction of a new nonconforming linear finite element on quadrilaterals recently developed by Park, we derive a dual weighted residual-based a posteriori error estimator (in the sense of Becker and Rannacher) for this finite element. By computing a corresponding dual solution we estimate the error with respect to a given target error functional. The reliability and efficiency of this estimator is analyzed in several numerical experiments.
Die vorliegende Erfindung betrifft eine Vorrichtung zum Halten eines lebenden Objektes bei physiologischen Messungen mit einem Basiselement und Mitteln zum Arretieren des lebenden Objektes, die atraumatische Ohrenhalter sowie ein Mundstück aufweisen, das mit einer Aussparung für die Zähne des Lebewesens versehen ist, mit einem Masseanteil von wenigstens 95% an glasfaserverstärktem Kunststoff.