Article
Refine
Year of publication
- 2004 (214) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (75)
- INB - Institut für Nano- und Biotechnologien (35)
- Fachbereich Elektrotechnik und Informationstechnik (27)
- IfB - Institut für Bioengineering (26)
- Fachbereich Wirtschaftswissenschaften (24)
- Fachbereich Energietechnik (19)
- Fachbereich Bauingenieurwesen (13)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Maschinenbau und Mechatronik (13)
- Fachbereich Chemie und Biotechnologie (8)
Document Type
- Article (214) (remove)
Keywords
- Hochschuldidaktik (2)
- 3D-Printing (1)
- Arbeitsbelastung (1)
- Bewertung von Studienleistungen (1)
- Bologna-Prozess (1)
- Didactics (1)
- Druckbeanspruchung (1)
- Druckbehälter (1)
- Druckbelastung (1)
- E-Learning (1)
A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes.
This study has been performed to design the combination of the new ClearPET TM (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal Positron Emission Tomography (PET) system, with a microComputed Tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.
This paper examines the positive and negative aspects of a range of interpretations of nearest-neighbours models. Measures-oriented and distributionoriented verification methods are applied to categorial, probabilistic and descriptive interpretations of nearest neighbours used operationally in avalanche forecasting in Scotland and Switzerland. The dependence of skill and accuracy measures on base rate is illustrated. The purpose of the forecast and the definition of events are important variables in determining the quality of the forecast. A discussion of the application of different interpretations in operational avalanche forecasting is presented.
Planwirtschaft
(2004)
Computerorientierte Lösung von Stabilitäts¬problemen im Bauwesen / Kindmann, R. ; Laumann, J.
(2004)
Farbanalyse von gebackenen oder frittierten Nahrungsmitteln und Vorhersage des Acrylamid-Wertes
(2004)
Comparison of solar hot water systems in solar settlements - decentralized or centralized systems?
(2004)