Article
Refine
Year of publication
- 2009 (199) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (76)
- INB - Institut für Nano- und Biotechnologien (32)
- Fachbereich Wirtschaftswissenschaften (31)
- IfB - Institut für Bioengineering (28)
- Fachbereich Elektrotechnik und Informationstechnik (23)
- Fachbereich Chemie und Biotechnologie (18)
- Fachbereich Energietechnik (15)
- Fachbereich Luft- und Raumfahrttechnik (9)
- Fachbereich Bauingenieurwesen (8)
- Fachbereich Maschinenbau und Mechatronik (8)
Document Type
- Article (199) (remove)
Keywords
- Atomausstieg (1)
- Blitzschutz (1)
- EGG (1)
- Europäische Energiepolitik (1)
- Hühnerzucht (1)
- Kernenergie (1)
- Larynx position (1)
- Tomography (1)
- Transfer impedance (1)
- Unterhaltung (1)
Nitratfreie Molke
(2009)
An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 µg·l−1 (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels.
Kommentierung zu §§ 705-740
(2009)
Self-Adjoint Operator
(2009)
Unitary Operator
(2009)
Projection
(2009)
Operator
(2009)
Density Operator
(2009)
The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics.