Conference Proceeding
Refine
Year of publication
Institute
- Fachbereich Elektrotechnik und Informationstechnik (302)
- Fachbereich Energietechnik (259)
- Fachbereich Medizintechnik und Technomathematik (243)
- Fachbereich Maschinenbau und Mechatronik (209)
- Fachbereich Luft- und Raumfahrttechnik (208)
- Solar-Institut Jülich (167)
- IfB - Institut für Bioengineering (152)
- Fachbereich Bauingenieurwesen (139)
- Fachbereich Wirtschaftswissenschaften (73)
- ECSM European Center for Sustainable Mobility (62)
- INB - Institut für Nano- und Biotechnologien (52)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (48)
- Fachbereich Chemie und Biotechnologie (35)
- Nowum-Energy (22)
- Kommission für Forschung und Entwicklung (17)
- Fachbereich Architektur (16)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (10)
- FH Aachen (7)
- Fachbereich Gestaltung (4)
- IaAM - Institut für angewandte Automation und Mechatronik (3)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (2)
- Institut fuer Angewandte Polymerchemie (2)
- Verwaltung (2)
- Digitalisierung in Studium & Lehre (1)
- Freshman Institute (1)
- Kommission für Planung und Finanzen (1)
- Senat (1)
Language
- English (1170)
- German (477)
- Italian (1)
- Multiple languages (1)
- Spanish (1)
Document Type
- Conference Proceeding (1650) (remove)
Keywords
- Biosensor (25)
- Blitzschutz (15)
- CAD (11)
- Finite-Elemente-Methode (11)
- civil engineering (11)
- Bauingenieurwesen (10)
- Lightning protection (9)
- Einspielen <Werkstoff> (6)
- Telekommunikationsmarkt (6)
- shakedown analysis (6)
Control mechanisms like Industrial Controls Systems (ICS) and its subgroup SCADA (Supervisory Control and Data Acquisition) are a prerequisite to automate industrial processes. While protection of ICS on process management level is relatively straightforward – well known office IT security mechanisms can be used – protection on field bus level is harder to achieve as there are real-time and production requirements like 24x7 to consider. One option to improve security on field bus level is to introduce controls that help to detect and to react on attacks. This paper introduces an initial set of intrusion detection mechanisms for the field bus protocol EtherCAT. To this end existing Ethernet attack vectors including packet injection and man-in-the-middle attacks are tested in an EtherCAT environment, where they could interrupt the EtherCAT network and may even cause physical damage. Based on the signatures of such attacks, a preprocessor and new rule options are defined for the open source intrusion detection system Snort demonstrating the general feasibility of intrusion detection on field bus level.
ICSs (Industrial Control Systems) and its subset SCADA systems (Supervisory Control and Data Acquisition) are getting exposed to a constant stream of new threats. The increasing importance of IT security in ICS requires viable methods to assess the security of ICS, its individual components, and its protocols. This paper presents a security analysis with focus on the communication protocols of a single PLC (Programmable Logic Controller). The PLC, a Beckhoff CX2020, is examined and new vulnerabilities of the system are revealed. Based on these findings recommendations are made to improve security of the Beckhoff system and its protocols.
Assessment of RF Safety of Transmit Coils at 7 Tesla by Experimental and Numerical Procedures (490.)
(2012)
This work presents a methodology for automated
damage-sensitive feature extraction and anomaly
detection under multivariate operational variability
for in-flight assessment of wings. The
method uses a passive excitation approach, i. e.
without the need for artificial actuation. The
modal system properties (natural frequencies and
damping ratios) are used as damage-sensitive
features. Special emphasis is placed on the use
of Fiber Bragg Grating (FBG) sensing technology
and the consideration of Operational and
Environmental Variability (OEV). Measurements
from a wind tunnel investigation with a composite
cantilever equipped with FBG and piezoelectric
sensors are used to successfully detect an impact
damage. In addition, the feasibility of damage
localisation and severity estimation is evaluated
based on the coupling found between damageand
OEV-induced feature changes.
The impact of wake model effects is investigated for two highly
non-planar lifting systems. Dependent on the geometrical
arrangement of the configuration, the wake model shape is found
to considerably affect the estimation. Particularly at higher angles
of attack, an accurate estimation based on the common linear wake
model approaches is involved.