Refine
Year of publication
- 2024 (3)
- 2023 (6)
- 2022 (9)
- 2021 (14)
- 2020 (10)
- 2019 (14)
- 2018 (22)
- 2017 (30)
- 2016 (13)
- 2015 (32)
- 2014 (35)
- 2013 (31)
- 2012 (35)
- 2011 (39)
- 2010 (24)
- 2009 (35)
- 2008 (17)
- 2007 (18)
- 2006 (22)
- 2005 (13)
- 2004 (34)
- 2003 (29)
- 2002 (24)
- 2001 (36)
- 2000 (26)
- 1999 (20)
- 1998 (11)
- 1997 (6)
- 1996 (9)
- 1995 (3)
- 1993 (3)
Document Type
- Article (542)
- Conference Proceeding (63)
- Part of a Book (11)
- Book (2)
- Other (2)
- Report (2)
- Patent (1)
Language
- English (551)
- German (71)
- Multiple languages (1)
Keywords
- Biosensor (7)
- Graduiertentagung (5)
- LAPS (4)
- field-effect sensor (4)
- hydrogen peroxide (4)
- Field-effect sensor (3)
- Label-free detection (3)
- Light-addressable potentiometric sensor (3)
- biosensors (3)
- capacitive field-effect sensor (3)
- tobacco mosaic virus (TMV) (3)
- Bacillus atrophaeus (2)
- Calorimetric gas sensor (2)
- Capacitive field-effect sensor (2)
- Graduate symposium (2)
- Hydrogen peroxide (2)
- Raman spectroscopy (2)
- Tobacco mosaic virus (TMV) (2)
- acetoin (2)
- capacitive field-effect sensors (2)
Institute
- Fachbereich Medizintechnik und Technomathematik (603)
- INB - Institut für Nano- und Biotechnologien (526)
- Fachbereich Chemie und Biotechnologie (40)
- FH Aachen (5)
- Nowum-Energy (5)
- Fachbereich Energietechnik (4)
- Institut fuer Angewandte Polymerchemie (3)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- Fachbereich Elektrotechnik und Informationstechnik (1)
Die Detektion von Schadstoffen repräsentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte Dünnschichtsensoren bieten eine kostengünstige Möglichkeit, „online“-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuführen. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgläsern zur Detektion von Schwermetallen in wässrigen Medien vorgestellt.
Heavy metal detection with semiconductor devices based on PLD-prepared chalcogenide glass thin films
(2007)
A novel photoexcitation method for the light-addressable potentiometric sensor (LAPS) realized a higher spatial resolution of chemical imaging. In this method, a modulated light probe, which generates the alternating photocurrent signal, is surrounded by a ring of constant light, which suppresses the lateral diffusion of photocarriers by enhancing recombination. A device simulation verified that a higher spatial resolution could be obtained by adjusting the gap between the modulated and constant light. It was also found that a higher intensity and a longer wavelength of constant light was more effective. However, there exists a tradeoff between the spatial resolution and the amplitude of the photocurrent, and thus, the signal-to-noise ratio. A tilted incidence of constant light was applied, which could achieve even higher resolution with a smaller loss of photocurrent.
A semiconductor field-effect device has been used for an enzymatically catalyzed degradation of biopolymers for the first time. This novel technique is capable to monitor the degradation process of multiple samples in situ and in real-time. As model system, the degradation of the biopolymer poly(D, L-lactic acid) has been monitored in the degradation medium containing the enzyme lipase from Rhizomucor miehei. The obtained results demonstrate the potential of capacitive field-effect sensors for degradation studies of biodegradable polymers.