Article
Refine
Year of publication
- 2021 (90) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (29)
- IfB - Institut für Bioengineering (23)
- Fachbereich Wirtschaftswissenschaften (16)
- Fachbereich Luft- und Raumfahrttechnik (11)
- INB - Institut für Nano- und Biotechnologien (10)
- Fachbereich Chemie und Biotechnologie (8)
- Fachbereich Bauingenieurwesen (6)
- Fachbereich Elektrotechnik und Informationstechnik (6)
- Fachbereich Energietechnik (3)
- Fachbereich Maschinenbau und Mechatronik (3)
Has Fulltext
- no (90) (remove)
Document Type
- Article (90) (remove)
Keywords
- Principal component analysis (2)
- capacitive field-effect sensor (2)
- constructive alignment (2)
- examination (2)
- harmonic radar (2)
- long-term retention (2)
- multimodal (2)
- practical learning (2)
- AlterG (1)
- Architektur (1)
An approach to automatically generate a dynamic energy simulation model in Modelica for a single existing building is presented. It aims at collecting data about the status quo in the preparation of energy retrofits with low effort and costs. The proposed method starts from a polygon model of the outer building envelope obtained from photogrammetrically generated point clouds. The open-source tools TEASER and AixLib are used for data enrichment and model generation. A case study was conducted on a single-family house. The resulting model can accurately reproduce the internal air temperatures during synthetical heating up and cooling down. Modelled and measured whole building heat transfer coefficients (HTC) agree within a 12% range. A sensitivity analysis emphasises the importance of accurate window characterisations and justifies the use of a very simplified interior geometry. Uncertainties arising from the use of archetype U-values are estimated by comparing different typologies, with best- and worst-case estimates showing differences in pre-retrofit heat demand of about ±20% to the average; however, as the assumptions made are permitted by some national standards, the method is already close to practical applicability and opens up a path to quickly estimate possible financial and energy savings after refurbishment.
Plant virus-like particles, and in particular, tobacco mosaic virus (TMV) particles, are increasingly being used in nano- and biotechnology as well as for biochemical sensing purposes as nanoscaffolds for the high-density immobilization of receptor molecules. The sensitive parameters of TMV-assisted biosensors depend, among others, on the density of adsorbed TMV particles on the sensor surface, which is affected by both the adsorption conditions and surface properties of the sensor. In this work, Ta₂O₅-gate field-effect capacitive sensors have been applied for the label-free electrical detection of TMV adsorption. The impact of the TMV concentration on both the sensor signal and the density of TMV particles adsorbed onto the Ta₂O₅-gate surface has been studied systematically by means of field-effect and scanning electron microscopy methods. In addition, the surface density of TMV particles loaded under different incubation times has been investigated. Finally, the field-effect sensor also demonstrates the label-free detection of penicillinase immobilization as model bioreceptor on TMV particles.
Aneurysmal subarachnoid hemorrhage (aSAH) is associated with early and delayed brain injury due to several underlying and interrelated processes, which include inflammation, oxidative stress, endothelial, and neuronal apoptosis. Treatment with melatonin, a cytoprotective neurohormone with anti-inflammatory, anti-oxidant and anti-apoptotic effects, has been shown to attenuate early brain injury (EBI) and to prevent delayed cerebral vasospasm in experimental aSAH models. Less is known about the role of endogenous melatonin for aSAH outcome and how its production is altered by the pathophysiological cascades initiated during EBI. In the present observational study, we analyzed changes in melatonin levels during the first three weeks after aSAH.
Dual frequency magnetic excitation of magnetic nanoparticles (MNP) enables enhanced biosensing applications. This was studied from an experimental and theoretical perspective: nonlinear sum-frequency components of MNP exposed to dual-frequency magnetic excitation were measured as a function of static magnetic offset field. The Langevin model in thermodynamic equilibrium was fitted to the experimental data to derive parameters of the lognormal core size distribution. These parameters were subsequently used as inputs for micromagnetic Monte-Carlo (MC)-simulations. From the hysteresis loops obtained from MC-simulations, sum-frequency components were numerically demodulated and compared with both experiment and Langevin model predictions. From the latter, we derived that approximately 90% of the frequency mixing magnetic response signal is generated by the largest 10% of MNP. We therefore suggest that small particles do not contribute to the frequency mixing signal, which is supported by MC-simulation results. Both theoretical approaches describe the experimental signal shapes well, but with notable differences between experiment and micromagnetic simulations. These deviations could result from Brownian relaxations which are, albeit experimentally inhibited, included in MC-simulation, or (yet unconsidered) cluster-effects of MNP, or inaccurately derived input for MC-simulations, because the largest particles dominate the experimental signal but concurrently do not fulfill the precondition of thermodynamic equilibrium required by Langevin theory.
Glucose oxidase (GOx) is an enzyme frequently used in glucose biosensors. As increased temperatures can enhance the performance of electrochemical sensors, we investigated the impact of temperature pulses on GOx that was drop-coated on flattened Pt microwires. The wires were heated by an alternating current. The sensitivity towards glucose and the temperature stability of GOx was investigated by amperometry. An up to 22-fold increase of sensitivity was observed. Spatially resolved enzyme activity changes were investigated via scanning electrochemical microscopy. The application of short (<100 ms) heat pulses was associated with less thermal inactivation of the immobilized GOx than long-term heating.
Der arbeitsrechtlich richtige Umgang mit Zeiten einer Dienstreise kann in der betrieblichen Praxis Probleme bereiten. Ob die Reisezeiten als solche Arbeitszeit i. S. des Arbeitszeitgesetzes (ArbZG ) darstellen, also bspw. auf die tägliche Höchstarbeitszeit angerechnet werden müssen oder nicht, ist oftmals genauso unklar wie die Frage, ob und inwieweit Reisezeiten vergütungspflichtig sind. Aber auch, ob ein Arbeitnehmer überhaupt zur Durchführung einer Dienstreise verpflichtet werden kann, ist ein möglicher Anlass von Streitigkeiten zwischen den Arbeitsvertragsparteien, wie verschiedene Gerichtsentscheidungen zeigen. Der nachfolgende Beitrag beantwortet die aufgeworfenen Fragen und gibt hierzu einen praxisorientierten Überblick.
Die Arbeitswelt ist im Umbruch. Der Bedarf an flexiblen Arbeitszeitmodellen nimmt stetig zu, wobei die Corona-Pandemie dieses Bedürfnis nochmals verschärft hat. Gerade auch in kleineren und mittleren Unternehmen wächst die Notwendigkeit, den Einsatz der Beschäftigten möglichst bedarfsgerecht zu steuern, also bei guter Auftragslage mehr Arbeitszeit abzurufen und bei ausbleibenden Aufträgen die Arbeitszeit zu reduzieren und somit bezahlte „Leerlaufzeiten“ zu vermeiden. Der Gesetzgeber stellt den Arbeitgebern hierfür das Instrument der sog. Abrufarbeit ( § 12 Teilzeit- und Befristungsgesetz – TzBfG ) zur Verfügung. In dem nachfolgenden Beitrag werden Möglichkeiten und Grenzen der Abrufarbeit skizziert und konkrete arbeitsvertragliche Gestaltungsmöglichkeiten aufgezeigt.
Eigenkapitalkosten sind eine wesentliche Determinante bei der Wertbestimmung von Unternehmen und Unternehmensteilen. Die Eigenkapitalkosten werden regelmäßig mittels des CAPM bestimmt. Für sog. konzerninterne Routinefunktionen mit geringem Risiko stellt diese Bestimmung mittels CAPM ein Problem dar, da börsennotierte Peergroups für eine zuverlässige Bestimmung des Beta-Faktors meist nicht identifizierbar sind. Damit ergeben sich bei Bewertungen von Routineunternehmen Unsicherheiten und Konfliktpotenzial in steuerlichen Betriebsprüfungen. Dieser Beitrag gibt einen Überblick der in der Praxis genutzten Ansätze und stellt eine theoretische Fundierung zur Bestimmung der Eigenkapitalkosten von konzerninternen Routinefunktionen vor. Dabei wird verdeutlicht, dass Eigenkapitalkosten von konzerninternen Routinefunktionen nicht denen des Gesamtkonzerns entsprechen und Praktikeransätze eine grundsätzliche Berechtigung besitzen.
Purpose Vascular risk factors and ocular perfusion are heatedly discussed in the pathogenesis of glaucoma. The retinal vessel analyzer (RVA, IMEDOS Systems, Germany) allows noninvasive measurement of retinal vessel regulation. Significant differences especially in the veins between healthy subjects and patients suffering from glaucoma were previously reported. In this pilot-study we investigated if localized vascular regulation is altered in glaucoma patients with altitudinal visual field defect asymmetry. Methods 15 eyes of 12 glaucoma patients with advanced altitudinal visual field defect asymmetry were included. The mean defect was calculated for each hemisphere separately (-20.99 ± 10.49 pro- found hemispheric visual field defect vs -7.36 ± 3.97 dB less profound hemisphere). After pupil dilation, RVA measurements of retinal arteries and veins were conducted using the standard protocol. The superior and inferior retinal vessel reactivity were measured consecutively in each eye. Results Significant differences were recorded in venous vessel constriction after flicker light stimulation and overall amplitude of the reaction (p \ 0.04 and p \ 0.02 respectively) in-between the hemispheres spheres. Vessel reaction was higher in the hemisphere corresponding to the more advanced visual field defect. Arterial diameters reacted similarly, failing to reach statistical significance. Conclusion Localized retinal vessel regulation is significantly altered in glaucoma patients with asymmetri altitudinal visual field defects. Veins supplying the hemisphere concordant to a less profound visual field defect show diminished diameter changes. Vascular dysregulation might be particularly important in early glaucoma stages prior to a significant visual field defect.