Refine
Year of publication
- 2024 (2)
- 2023 (14)
- 2022 (16)
- 2021 (11)
- 2020 (13)
- 2019 (17)
- 2018 (18)
- 2017 (12)
- 2016 (36)
- 2015 (30)
- 2014 (31)
- 2013 (29)
- 2012 (27)
- 2011 (28)
- 2010 (26)
- 2009 (24)
- 2008 (16)
- 2007 (20)
- 2006 (17)
- 2005 (20)
- 2004 (15)
- 2003 (14)
- 2002 (19)
- 2001 (18)
- 2000 (12)
- 1999 (16)
- 1998 (31)
- 1997 (25)
- 1996 (19)
- 1995 (36)
- 1994 (29)
- 1993 (21)
- 1992 (27)
- 1991 (15)
- 1990 (20)
- 1989 (20)
- 1988 (19)
- 1987 (16)
- 1986 (11)
- 1985 (7)
- 1984 (10)
- 1983 (10)
- 1982 (3)
- 1981 (3)
- 1980 (3)
- 1979 (8)
- 1978 (2)
- 1976 (2)
- 1975 (3)
- 1973 (2)
- 1972 (2)
- 1971 (2)
Document Type
- Article (597)
- Patent (117)
- Book (65)
- Conference Proceeding (34)
- Part of a Book (21)
- Report (5)
- Bachelor Thesis (3)
- Doctoral Thesis (3)
- Diploma Thesis (1)
- Preprint (1)
Language
- English (534)
- German (310)
- Multiple languages (2)
- Spanish (1)
Keywords
- Heparin (3)
- Bacillaceae (2)
- Biorefinery (2)
- Biotechnological application (2)
- Chemometrics (2)
- IR spectroscopy (2)
- NMR spectroscopy (2)
- Principal component analysis (2)
- Standardization (2)
- Subtilases (2)
- Subtilisin (2)
- bubble column (2)
- methanation (2)
- plug flow reactor (2)
- qNMR (2)
- (Poly)saccharides (1)
- (R)- or (S)- gamma-valerolactone (1)
- 4-hydroxy valeric acid (1)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
Institute
- Fachbereich Chemie und Biotechnologie (847) (remove)
Modulation of muscle-tendon interaction in the human triceps surae during an energy dissipation task
(2017)
Nitratfreie Molke
(2009)
An immunochromatographic lateral flow dipstick assay for the fast detection of microcystin-LR was developed. Colloid gold particles with diameters of 40 nm were used as red-colored antibody labels for the visual detection of the antigen. The new dipstick sensor is capable of detecting down to 5 µg·l−1 (ppb; total inversion of the color signal) or 1 ppb (observation of color grading) of microcystin-LR. The course of the labeling reaction was observed via spectrometric wave shifts caused by the change of particle size during the binding of antibodies. Different stabilizing reagents showed that especially bovine serum albumin (BSA) and casein increase the assays sensitivity and the conjugate stability. Performance of the dipsticks was quantified by pattern processing of capture zone CCD images. Storage stability of dipsticks and conjugate suspensions over 115 days under different conditions were monitored. The ready-to-use dipsticks were successfully tested with microcystin-LR-spiked samples of outdoor drinking- and salt water and applied to the tissue of microcystin-fed mussels.
The invention relates to a system for the implementation of chemical, biological or physical reactions, consisting of - one or more magnetic micro-reactors, each comprising a shell made of hydrophobic magnetic nanoparticles encapsulating an aqueous core, - a plane platform comprising a surface to receive the micro-reactors, - a source that generates a magnetic field above or underneath the platform for manipulating the one or more hydrophobic magnetic micro-reactors, or for moving them along the surface of the platform from one position to another position, characterized in that the aqueous core of the one or more magnetic micro-reactors contains a reaction solution or buffer, and wherein the magnetic field generated by the source correlates to a defined position on the surface of the platform.
Die vorliegende Erfindung betrifft eine Vorrichtung und ein Verfahren zur Bestimmung des Kontaktwinkels eines flüssigen oder mit Flüssigkeit gefüllten Körpers. Dieser besteht aus einem Träger (1) und einer damit verbundenen, in einem Winkelbereich von mehr als 0° bis maximal 90° neigbaren Ebene (8) mit einer darin ausgebildeten Abrollbahn (9) für den flüssigen oder mit Flüssigkeit gefüllten Körper. An der Ebene (8) sind mehrere Sensoren (11, 12) zur Erfassung der Rolldauer des Körpers entlang der Rollstrecke angeordnet. Erfindungsgemäß ist vorgesehen, dass die Einstellung des Neigungswinkels der Ebene (8) über ein Winkelmessgerät (10) erfolgt, wodurch ein Abrollwinkel erfassbar ist, bei dem der Körper in Bewegung gerät. Aus der Rolldauer, der Rollstrecke und dem Abrollwinkel wird der Kontaktwinkel des Körpers ermittelt.
Characterization and evaluation of lignocellulosic biomass 130 hydrolysates for ABE fermentation
(2016)
The immobilization of NAD+-dependent dehydrogenases, in combination with a diaphorase, enables the facile development of multiparametric sensing devices. In this work, an amperometric biosensor array for simultaneous determination of ethanol, formate, d- and l-lactate is presented. Enzyme immobilization on platinum thin-film electrodes was realized by chemical cross-linking with glutaraldehyde. The optimization of the sensor performance was investigated with regard to enzyme loading, glutaraldehyde concentration, pH, cofactor concentration and temperature. Under optimal working conditions (potassium phosphate buffer with pH 7.5, 2.5 mmol L-1 NAD+, 2.0 mmol L-1 ferricyanide, 25 °C and 0.4% glutaraldehyde) the linear working range and sensitivity of the four sensor elements was improved. Simultaneous and cross-talk free measurements of four different metabolic parameters were performed successfully. The reliable analytical performance of the biosensor array was demonstrated by application in a clarified sample of inoculum sludge. Thereby, a promising approach for on-site monitoring of fermentation processes is provided.