Refine
Year of publication
- 2024 (3)
- 2023 (14)
- 2022 (37)
- 2021 (23)
- 2020 (35)
- 2019 (27)
- 2018 (22)
- 2017 (27)
- 2016 (17)
- 2015 (23)
- 2014 (40)
- 2013 (36)
- 2012 (20)
- 2011 (29)
- 2010 (35)
- 2009 (35)
- 2008 (28)
- 2007 (24)
- 2006 (29)
- 2005 (39)
- 2004 (35)
- 2003 (25)
- 2002 (33)
- 2001 (27)
- 2000 (35)
- 1999 (28)
- 1998 (28)
- 1997 (31)
- 1996 (44)
- 1995 (24)
- 1994 (30)
- 1993 (23)
- 1992 (17)
- 1991 (11)
- 1990 (11)
- 1989 (16)
- 1988 (16)
- 1987 (20)
- 1986 (20)
- 1985 (16)
- 1984 (14)
- 1983 (14)
- 1982 (10)
- 1981 (14)
- 1980 (7)
- 1979 (9)
- 1978 (3)
- 1977 (3)
- 1976 (1)
- 1975 (4)
- 1974 (1)
- 1973 (1)
- 1972 (1)
Institute
- Fachbereich Energietechnik (1115) (remove)
Language
- English (588)
- German (524)
- Multiple languages (1)
- Dutch (1)
- Spanish (1)
Document Type
- Article (609)
- Conference Proceeding (259)
- Book (125)
- Part of a Book (84)
- Doctoral Thesis (10)
- Conference: Meeting Abstract (7)
- Report (7)
- Other (4)
- Talk (3)
- Diploma Thesis (2)
Keywords
- Blitzschutz (18)
- Lightning protection (11)
- Earthquake (5)
- Diversity Management (4)
- Energy storage (4)
- Power plants (4)
- Risikomanagement (4)
- Seismic design (4)
- reinforced concrete (4)
- Associated liquids (3)
The Effect of Openings on Out-of-Plane Capacity of Masonry Infilled Reinforced Concrete Frames
(2018)
Cryopumps without liquid nitrogen shielding are used to provide a vacuum of 10−6 torr in the spectrometer. The vacuum system is subdivided in three sections that can be separated by valves.
The first section (scattering chamber) has a volume of 60 l, two rotation transmissions with 35 cm dia and a sliding seal that allows a rotation of 160° without deteriorating the vacuum. The second section includes the vacuum chambers inside the magnets with 6 × 80 cm cross-section and a length of 1200 cm. The third section (detector box) has a volume of 4300 l and contains a moveable detector system. The gas inside the detector with a pressure of 760 torr is separated from the vacuum by a 15 μm mylar foil with an area of 300 cm2. The detector box can be valved off by a valve with the dimension of 10 × 100 cm.
The layout of system is given. The instrumentation and the interlock system are described. First experiences with this system are presented.
With proven impact of statistical fracture analysis on fracture classifications, it is desirable to minimize the manual work and to maximize repeatability of this approach. We address this with an algorithm that reduces the manual effort to segmentation, fragment identification and reduction. The fracture edge detection and heat map generation are performed automatically. With the same input, the algorithm always delivers the same output. The tool transforms one intact template consecutively onto each fractured specimen by linear least square optimization, detects the fragment edges in the template and then superimposes them to generate a fracture probability heat map.
We hypothesized that the algorithm runs faster than the manual evaluation and with low (< 5 mm) deviation. We tested the hypothesis in 10 fractured proximal humeri and found that it performs with good accuracy (2.5 mm ± 2.4 mm averaged Euclidean distance) and speed (23 times faster). When applied to a distal humerus, a tibia plateau, and a scaphoid fracture, the run times were low (1–2 min), and the detected edges correct by visual judgement. In the geometrically complex acetabulum, at a run time of 78 min some outliers were considered acceptable. An automatically generated fracture probability heat map based on 50 proximal humerus fractures matches the areas of high risk of fracture reported in medical literature.
Such automation of the fracture analysis method is advantageous and could be extended to reduce the manual effort even further.
The adsorption of fluor-carbon complexes on GaAs(110) studied by electron energy loss spectroscopy
(1986)
Textile reinforced concrete. Part I: Process model for collaborative research and development
(2003)
One of the most important parameters in a burning chamber - in power stations, in waste to energy plants - is the temperature. This temperature is in the range of 700-1500 °C - one of the most advanced measuring methods being the acoustic pyrometry with the possibility of producing temperature mapping in one level of the burning chamber - comparable to computer tomography. The results of these measurements discussed in the presentation can be used - to fulfil the legal requirements in the FRG or in the EU - to equalise the temperature in one level of the burning chamber to optimise the steam production (better efficiency of the plant) and to minimise the production of temperature controlled flue gas components (NO, CO a. o.) - to control the SNCR-process if used.