Refine
Year of publication
- 2024 (127)
- 2023 (255)
- 2022 (301)
- 2021 (293)
- 2020 (241)
- 2019 (378)
- 2018 (259)
- 2017 (259)
- 2016 (277)
- 2015 (301)
- 2014 (301)
- 2013 (301)
- 2012 (332)
- 2011 (328)
- 2010 (342)
- 2009 (369)
- 2008 (311)
- 2007 (312)
- 2006 (330)
- 2005 (303)
- 2004 (323)
- 2003 (254)
- 2002 (250)
- 2001 (221)
- 2000 (245)
- 1999 (236)
- 1998 (242)
- 1997 (220)
- 1996 (202)
- 1995 (192)
- 1994 (174)
- 1993 (154)
- 1992 (144)
- 1991 (100)
- 1990 (108)
- 1989 (111)
- 1988 (104)
- 1987 (105)
- 1986 (81)
- 1985 (84)
- 1984 (75)
- 1983 (70)
- 1982 (57)
- 1981 (54)
- 1980 (61)
- 1979 (58)
- 1978 (52)
- 1977 (32)
- 1976 (30)
- 1975 (28)
- 1974 (17)
- 1973 (12)
- 1972 (17)
- 1971 (11)
- 1970 (2)
- 1969 (2)
- 1968 (2)
- 1967 (1)
- 1963 (1)
- 1925 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (2073)
- Fachbereich Elektrotechnik und Informationstechnik (1184)
- Fachbereich Wirtschaftswissenschaften (1158)
- Fachbereich Energietechnik (1115)
- Fachbereich Chemie und Biotechnologie (912)
- Fachbereich Maschinenbau und Mechatronik (868)
- Fachbereich Luft- und Raumfahrttechnik (797)
- Fachbereich Bauingenieurwesen (711)
- IfB - Institut für Bioengineering (689)
- INB - Institut für Nano- und Biotechnologien (615)
Language
- German (5114)
- English (4908)
- Russian (14)
- Portuguese (6)
- Multiple languages (5)
- Spanish (3)
- Dutch (2)
- Italian (1)
Document Type
- Article (5645)
- Conference Proceeding (1639)
- Book (1079)
- Part of a Book (559)
- Bachelor Thesis (327)
- Patent (174)
- Report (101)
- Doctoral Thesis (79)
- Other (76)
- Administrative publication (76)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Illustration (23)
Zugriffsart
- campus (2147)
- weltweit (1860)
- bezahl (765)
- fachbereichsweit (FB4) (34)
Thin film chemical sensors based on chalcogenide glasses for „electronic tongue“ applications
(2001)
Die Allianz Chronischer Seltener Erkrankungen (ACHSE) ist das einzige krankheitsübergreifende Netzwerk von und für Menschen mit einer seltenen Erkrankung in Deutschland. Insgesamt sind 4 Millionen Menschen in Deutschland von einer der rund 8.000 seltenen Krankheiten betroffen.
Durch die Seltenheit der verschiedenen Krankheiten ist es oft schwer, Experten zu finden, die richtige Versorgung sicherzustellen oder Studien durchzuführen. Betroffene fühlen sich oft nicht wahrgenommen und alleine gelassen. Die ACHSE dient als unabhängige Schnittstelle und Knotenpunkt zwischen Betroffenen, Regierung, Politik und Wirtschaft. Gemeinsam bündeln sich hier 130 Patientenorganisationen unter einem Dach, um die Betroffenen in den Fokus zu rücken. Ziel der Bachelorarbeit ist die Entwicklung eines Erscheinungsbildes sowie einer Kampagne, die das Thema mehr ins Bewusstsein der Öffentlichkeit bringt und informiert.
Purpose
In the determination of the measurement uncertainty, the GUM procedure requires the building of a measurement model that establishes a functional relationship between the measurand and all influencing quantities. Since the effort of modelling as well as quantifying the measurement uncertainties depend on the number of influencing quantities considered, the aim of this study is to determine relevant influencing quantities and to remove irrelevant ones from the dataset.
Design/methodology/approach
In this work, it was investigated whether the effort of modelling for the determination of measurement uncertainty can be reduced by the use of feature selection (FS) methods. For this purpose, 9 different FS methods were tested on 16 artificial test datasets, whose properties (number of data points, number of features, complexity, features with low influence and redundant features) were varied via a design of experiments.
Findings
Based on a success metric, the stability, universality and complexity of the method, two FS methods could be identified that reliably identify relevant and irrelevant influencing quantities for a measurement model.
Originality/value
For the first time, FS methods were applied to datasets with properties of classical measurement processes. The simulation-based results serve as a basis for further research in the field of FS for measurement models. The identified algorithms will be applied to real measurement processes in the future.
We present the production of 58mCo on a small, 13 MeV medical cyclotron utilizing a siphon style liquid target system. Different concentrated iron(III)-nitrate solutions of natural isotopic distribution were irradiated at varying initial pressures and subsequently separated by solid phase extraction chromatography. The radio cobalt (58m/gCo and 56Co) was successfully produced with saturation activities of (0.35 ± 0.03) MBq μA−1 for 58mCo with a separation recovery of (75 ± 2) % of cobalt after one separation step utilizing LN-resin.
Density reduction effects on the production of [11C]CO2 in Nb-body targets on a medical cyclotron
(2023)
Medical isotope production of 11C is commonly performed in gaseous targets. The power deposition of the proton beam during the irradiation decreases the target density due to thermodynamic mixing and can cause an increase of penetration depth and divergence of the proton beam. In order to investigate the difference how the target-body length influences the operation conditions and the production yield, a 12 cm and a 22 cm Nb-target body containing N2/O2 gas were irradiated using a 13 MeV proton cyclotron. It was found that the density reduction has a large influence on the pressure rise during irradiation and the achievable radioactive yield. The saturation activity of [11C]CO2 for the long target (0.083 Ci/μA) is about 10% higher than in the short target geometry (0.075 Ci/μA).
Bio-feedstocks
(2011)