Refine
Year of publication
- 2024 (14)
- 2023 (28)
- 2022 (19)
- 2021 (26)
- 2020 (29)
- 2019 (44)
- 2018 (43)
- 2017 (37)
- 2016 (32)
- 2015 (30)
- 2014 (41)
- 2013 (43)
- 2012 (38)
- 2011 (40)
- 2010 (35)
- 2009 (38)
- 2008 (41)
- 2007 (38)
- 2006 (27)
- 2005 (25)
- 2004 (35)
- 2003 (27)
- 2002 (29)
- 2001 (31)
- 2000 (31)
- 1999 (31)
- 1998 (26)
- 1997 (33)
- 1996 (24)
- 1995 (22)
- 1994 (21)
- 1993 (18)
- 1992 (13)
- 1991 (14)
- 1990 (9)
- 1989 (17)
- 1988 (11)
- 1987 (8)
- 1986 (9)
- 1985 (9)
- 1984 (3)
- 1983 (7)
- 1982 (4)
- 1981 (3)
- 1980 (12)
- 1979 (6)
- 1978 (7)
- 1977 (1)
- 1976 (7)
- 1975 (3)
- 1974 (4)
- 1973 (1)
- 1972 (3)
- 1971 (2)
- 1970 (1)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (1150) (remove)
Has Fulltext
- no (1150) (remove)
Document Type
- Article (629)
- Conference Proceeding (286)
- Book (112)
- Part of a Book (64)
- Patent (17)
- Report (9)
- Other (8)
- Conference: Meeting Abstract (6)
- Contribution to a Periodical (6)
- Doctoral Thesis (6)
Keywords
- Enterprise Architecture (5)
- MINLP (5)
- Engineering optimization (4)
- Digitale Transformation (3)
- Digitalisierung (3)
- Gamification (3)
- Literaturanalyse (3)
- Optimization (3)
- Powertrain (3)
- Referenzmodellierung (3)
Design of a Measurement Setup for the Impedance of Low-Resistance Plate-Conductors in the RF-Range
(2006)
Zur Unterstützung des Transformationsbedarfs von Telekommunikationsunternehmen sind die Referenzmodelle des TM Forums in der Praxis weltweit anerkannt. Dabei findet jedoch meist eine losgelöste Nutzung für spezifische Einzelthemen statt. Daher führt dieser Artikel die bestehenden Inhalte in einer industriespezifischen, übergreifenden Referenzarchitektur zusammen. Der Fokus liegt auf den Ebenen Aufbauorganisation, Prozesse, Applikationen und Daten. Darüber hinaus werden inhaltliche Architekturdomänen zur Strukturierung angeboten. Die Referenzarchitektur ist hierarchisch aufgebaut und wird hier beispielhaft für ausgewählte, aggregierte Inhalte beschrieben. Als erste Evaluation wird die Anwendung der Referenzarchitektur in drei Praxisprojekten erläutert.
Cardiac MR (CMR) at ultrahigh (≥7.0 T) fields is regarded as one of the most challenging MRI applications. At 7.0 T image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Detrimental effects bear the potential to spoil the signal-to-noise (SNR) and contrast-to-noise (CNR) benefits of cardiac MR (CMR) at 7.0 T. B₁⁺-inhomogeneities and signal voids represent the main challenges. Various pioneering coil concepts have been proposed to tackle these issues, enabling cardiac MRI at 7.0 T. This includes a trend towards an ever larger number of transmit and receive channels. This approach affords multi-dimensional B₁⁺ modulations to improve B₁⁺ shimming performance and to enhance RF efficiency. Also, parallel imaging benefits from a high number of receive channels enabling two-dimensional acceleration. Realizing the limitations of existing coil designs tailored for UHF CMR and recognizing the opportunities of a many element TX/RX channel architecture this work proposes a modular, two dimensional 32-channel transmit and receive array using loop elements and examines its efficacy for enhanced B¹+ homogeneity and improved parallel imaging performance.
This paper covers the use of the magnetic Wiegand effect to design an innovative incremental encoder. First, a theoretical design is given, followed by an estimation of the achievable accuracy and an optimization in open-loop operation.
Finally, a successful experimental verification is presented. For this purpose, a permanent magnet synchronous machine is controlled in a field-oriented manner, using the angle information of the prototype.
Pure analytical or experimental methods can only find a control strategy for technical systems with a fixed setup. In former contributions we presented an approach that simultaneously finds the optimal topology and the optimal open-loop control of a system via Mixed Integer Linear Programming (MILP). In order to extend this approach by a closed-loop control we present a Mixed Integer Program for a time discretized tank level control. This model is the basis for an extension by combinatorial decisions and thus for the variation of the network topology. Furthermore, one is able to appraise feasible solutions using the global optimality gap.
Purpose:
To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle.
Materials and Methods:
The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.05–7.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization.
Results:
The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs.
Conclusion:
This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364–372. © 2012 Wiley Periodicals, Inc.
A novel method to determine the extruded length of a metallic wire for a directed energy deposition (DED) process using a microwave (MW) plasma jet with a straight-through wire feed is presented. The method is based on the relative comparison of the measured frequency response obtained by the large-signal scattering parameter (Hot-S) technique. In the practical working range, repeatability of less than 6% for a nonactive plasma and 9% for the active plasma state is found. Measurements are conducted with a focus on a simple solution to decrease the processing time and reduce the integration time of the process into the existing hardware. It is shown that monitoring a single frequency for magnitude and phase changes is sufficient to achieve good accuracy. A combination of different measurement values to determine the length is possible. The applicability to different diameter of the same material is shown as well as a contact detection of the wire and metallic substrate.
Due to the decarbonization of the energy sector, the electric distribution grids are undergoing a major transformation, which is expected to increase the load on the operating resources due to new electrical loads and distributed energy resources. Therefore, grid operators need to gradually move to active grid management in order to ensure safe and reliable grid operation. However, this requires knowledge of key grid variables, such as node voltages, which is why the mass integration of measurement technology (smart meters) is necessary. Another problem is the fact that a large part of the topology of the distribution grids is not sufficiently digitized and models are partly faulty, which means that active grid operation management today has to be carried out largely blindly. It is therefore part of current research to develop methods for determining unknown grid topologies based on measurement data. In this paper, different clustering algorithms are presented and their performance of topology detection of low voltage grids is compared. Furthermore, the influence of measurement uncertainties is investigated in the form of a sensitivity analysis.
Objective
The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments.
Methods
MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR.
Results
The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated.
Conclusions
MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur.
Development of a subject-oriented reference process model for the telecommunications industry
(2016)
Generally the usage of reference models can be structured top-down or bottom-up. The practical need of agile change and flexible organizational implementation requires a consistent mapping to an operational level. In this context, well-established reference process models are typically structured top-down. The subject-oriented Business Process Management (sBPM) offers a modeling concept that is structured bottom-up and concentrates on the process actors on an
operational level. This paper applies sBPM to the enhanced Telecom Operations Map (eTOM), a well-accepted reference process model in the telecommunications industry. The resulting design artifact is a concrete example for a combination of a bottom-up and top-down developed reference model. The results are evaluated and confirmed in practical context through the involvement of the industry body TMForum.
In order to reduce energy consumption of homes, it is important to make transparent which devices consume how much energy. However, power consumption is often only monitored aggregated at the house energy meter. Disaggregating this power consumption into the contributions of individual devices can be achieved using Machine Learning. Our work aims at making state of the art disaggregation algorithms accessibe for users of the open source home automation platform Home Assistant.
The development of resilient technical systems is a challenging task, as the system should adapt automatically to unknown disturbances and component failures. To evaluate different approaches for deriving resilient technical system designs, we developed a modular test rig that is based on a pumping system. On the basis of this example
system, we present metrics to quantify resilience and an algorithmic approach to improve resilience. This approach enables the pumping system to automatically react on unknown disturbances and to reduce the impact of component failures. In this case, the system is able to automatically adapt its topology by activating additional valves. This enables the system to still reach a minimum performance, even in case of failures. Furthermore, timedependent disturbances are evaluated continuously, deviations from the original state are automatically detected and anticipated in the future. This allows to reduce the impact of future disturbances and leads to a more resilient
system behaviour.