Refine
Year of publication
- 2024 (6)
- 2023 (17)
- 2022 (20)
- 2021 (12)
- 2020 (13)
- 2019 (16)
- 2018 (22)
- 2017 (12)
- 2016 (44)
- 2015 (30)
- 2014 (46)
- 2013 (29)
- 2012 (40)
- 2011 (28)
- 2010 (34)
- 2009 (30)
- 2008 (16)
- 2007 (20)
- 2006 (17)
- 2005 (20)
- 2004 (15)
- 2003 (14)
- 2002 (19)
- 2001 (18)
- 2000 (12)
- 1999 (16)
- 1998 (31)
- 1997 (25)
- 1996 (19)
- 1995 (36)
- 1994 (29)
- 1993 (21)
- 1992 (27)
- 1991 (15)
- 1990 (20)
- 1989 (20)
- 1988 (19)
- 1987 (16)
- 1986 (11)
- 1985 (7)
- 1984 (10)
- 1983 (10)
- 1982 (3)
- 1981 (3)
- 1980 (3)
- 1979 (8)
- 1978 (2)
- 1976 (2)
- 1975 (3)
- 1973 (2)
- 1972 (2)
- 1971 (2)
Institute
- Fachbereich Chemie und Biotechnologie (912) (remove)
Language
- English (551)
- German (358)
- Multiple languages (2)
- Spanish (1)
Document Type
- Article (602)
- Patent (117)
- Book (65)
- Conference: Meeting Abstract (55)
- Conference Proceeding (35)
- Part of a Book (21)
- Report (6)
- Bachelor Thesis (3)
- Doctoral Thesis (3)
- Conference Poster (1)
Keywords
- Heparin (3)
- Bacillaceae (2)
- Biorefinery (2)
- Biotechnological application (2)
- Butanol (2)
- Chemometrics (2)
- IR spectroscopy (2)
- NMR spectroscopy (2)
- Principal component analysis (2)
- Standardization (2)
Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions.
Optimierung der selektiven Aufarbeitung von Proteinen mit Aptamer-funktionalisierten Magnetpartikeln
(2012)
Die Herstellung pharmakologisch relevanter Proteine durch Mikroorganismen führt eine mehrstufige Aufarbeitung mit sich. Durch die Verwendung von Aptameren, kurzen einzelsträngigen DNA- oder RNA-Oligonukleotiden immobilisiert auf funktionalisierten, wiederverwendbaren Magnetpartikeln, können mehrere dieser Abtrennungsoperationen kombiniert und damit die Prozesskosten minimiert werden. Aufgrund der definierten dreidimensionalen Struktur können Aptamere kleine organische Moleküle hochspezifisch binden. Im vorgestellten Projekt wird die Aufarbeitung von His6-GFP als Modellprotein mithilfe der mit Aptamer funktionalisierten Magnetpartikel durchgeführt. In bisherigen Versuchen wurde die Bindung von Aptameren auf den magnetischen Partikeln sowie die Bindung des Modellproteins GFP auf den Partikeln optimiert. Des Weiteren wurden mehrere Strategien zur Elution des GFPs von den Partikeln verfolgt, um den Proteinertrag zu maximieren und die Partikel rezyklieren zu können. Die Untersuchung unspezifischer Bindungen von Zelltrümmern und Proteinen an die Magnetpartikel wurde mithilfe eines konfokalen Laser-Scanning-Mikroskops durchgeführt.
Im vom BMELV/FNR geförderten SynRg-Projekt wurde unter anderem Rapsschrot untersucht, um Polyphenole zu isolieren und aufzureinigen. Diese sollen anschließend als Basisbausteine für Polymere dienen und ihnen neuartige Eigenschaften verleihen. Derzeit wird an der Polyphenolextraktion gearbeitet, da bei organischen oder wässrigen Extraktionsprozessen überwiegend Sinapin, ein Cholinester der Sinapinsäure, vorliegt und dieses nicht für die Polymerbildung eingesetzt werden kann. Für die im Fokus stehende Sinapinsäure wird deshalb eine simultane Extraktion und enzymatische oder chemische Hydrolyse von Sinapin zu Sinapinsäure durchgeführt. Durch die Hydrolyse konnte die Sinapinsäureausbeute bereits um den Faktor 6,2 auf 15,8 mg g⁻¹ gegenüber einer reinwässrigen Extraktion gesteigert werden. Für die Aufreinigung des an Sinapinsäure reichen Extrakts erfolgt anschließend ein adsorptiver Aufarbeitungsschritt, bei dem Zeolithe zum Einsatz kommen. Mit diesem Material ist es möglich, die Sinapinsäure quantitativ zu adsorbieren und später mit 70 %igem Ethanol bei 60 °C zu desorbieren. Bei den Adsorbern handelt es sich um b-Zeolithe von der Süd-Chemie AG.
Primäre Ziele der Hydrolyse pflanzlicher nachwachsender Rohstoffe sind möglichst hohe Zuckerkonzentrationen für nachfolgende Fermentationen und eine Maximierung der Produktivität. Zur Optimierung dieser Prozesse wird Organosolv-aufgeschlossene Buchenholz-Cellulose verwendet. Die Hydrolyse des Faserstoffes erfolgt mithilfe von Novozymes CTec2-Enzymen. Die Hydrolysen konnten durch neue Rührerelemente auf einen Maßstab von 1000 L übertragen werden. Dabei konnten maximale Ausbeuten (g Glucose g –1 Glucose im Faserstoff) bis 81 g g – 1 und Konzentrationen von 152 g L –1 erreicht werden. Zurzeit können unter Einsatz eines Feststoffreaktors Cellulosefasern in einer Konzentration bis 400 g L –1 enzymatisch hydrolysiert werden. Die cellulolytischen Enzyme stoßen bei hohen Feststoffkonzentrationen an ihre Grenzen. Mit steigendem Feststoffgehalt nimmt die Hydrolyseausbeute ab. Ein Ansatz zur Steigerung der Effizienz ist der Einsatz ligninolytischer Enzyme, die Ligninreste an der Organosolv-Cellulose aufschließen können. Eine solche Verbesserung der Zugänglichkeit für cellulolytische Enzyme an ihr Substrat wurde durch Kulturüberstände verschiedener ligninolytischer Pilze erreicht. Mit Kulturüberständen von Stereum sp. sind Steigerungen der Glucoseausbeuten um bis zu 30 % möglich.
The immobilization of NAD+-dependent dehydrogenases, in combination with a diaphorase, enables the facile development of multiparametric sensing devices. In this work, an amperometric biosensor array for simultaneous determination of ethanol, formate, d- and l-lactate is presented. Enzyme immobilization on platinum thin-film electrodes was realized by chemical cross-linking with glutaraldehyde. The optimization of the sensor performance was investigated with regard to enzyme loading, glutaraldehyde concentration, pH, cofactor concentration and temperature. Under optimal working conditions (potassium phosphate buffer with pH 7.5, 2.5 mmol L-1 NAD+, 2.0 mmol L-1 ferricyanide, 25 °C and 0.4% glutaraldehyde) the linear working range and sensitivity of the four sensor elements was improved. Simultaneous and cross-talk free measurements of four different metabolic parameters were performed successfully. The reliable analytical performance of the biosensor array was demonstrated by application in a clarified sample of inoculum sludge. Thereby, a promising approach for on-site monitoring of fermentation processes is provided.
High gradient magnetic separation (HGMS) has been established since the early 1970s. A more recent application of these systems is the use in bioprocesses. To integrate the HGMS in a fermentation process, it is necessary to optimize the separation matrix with regard to the magnetic separation characteristics and permeability of the non-magnetizable components of the fermentation broth. As part of the work presented here, a combined fluidic and magnetic force finite element model simulation was created using the software COMSOL Multiphysics and compared with separation experiments. Finally, as optimal lattice orientation of the separation matrix, a transversal rhombohedral arrangement was defined. The high suitability of the new filter matrix has been verified by separation experiments.
Bacillus subtilis and Bacillus licheniformis are widely used for the large-scale industrial production of proteins. These strains can efficiently secrete proteins into the culture medium using the general secretion (Sec) pathway. A characteristic feature of all secreted proteins is their N-terminal signal peptides, which are recognized by the secretion machinery. Here, we have studied the production of an industrially important secreted protease, namely, subtilisin BPN′ from Bacillus amyloliquefaciens. One hundred seventy-three signal peptides originating from B. subtilis and 220 signal peptides from the B. licheniformis type strain were fused to this secretion target and expressed in B. subtilis, and the resulting library was analyzed by high-throughput screening for extracellular proteolytic activity. We have identified a number of signal peptides originating from both organisms which produced significantly increased yield of the secreted protease. Interestingly, we observed that levels of extracellular protease were improved not only in B. subtilis, which was used as the screening host, but also in two different B. licheniformis strains. To date, it is impossible to predict which signal peptide will result in better secretion and thus an improved yield of a given extracellular target protein. Our data show that screening a library consisting of homologous and heterologous signal peptides fused to a target protein can identify more-effective signal peptides, resulting in improved protein export not only in the original screening host but also in different production strains.
In proton therapy, the dose from secondary neutrons to the patient can contribute to side effects and the creation of secondary cancer. A simple and fast detection system to distinguish between dose from protons and neutrons both in pretreatment verification as well as potentially in vivo monitoring is needed to minimize dose from secondary neutrons. Two 3 mm long, 1 mm diameter organic scintillators were tested for candidacy to be used in a proton–neutron discrimination detector. The SCSF-3HF (1500) scintillating fibre (Kuraray Co. Chiyoda-ku, Tokyo, Japan) and EJ-260 plastic scintillator (Eljen Technology, Sweetwater, TX, USA) were irradiated at the TRIUMF Neutron Facility and the Proton Therapy Research Centre. In the proton beam, we compared the raw Bragg peak and spread-out Bragg peak response to the industry standard Markus chamber detector. Both scintillator sensors exhibited quenching at high LET in the Bragg peak, presenting a peak-to-entrance ratio of 2.59 for the EJ-260 and 2.63 for the SCSF-3HF fibre, compared to 3.70 for the Markus chamber. The SCSF-3HF sensor demonstrated 1.3 times the sensitivity to protons and 3 times the sensitivity to neutrons as compared to the EJ-260 sensor. Combined with our equations relating neutron and proton contributions to dose during proton irradiations, and the application of Birks’ quenching correction, these fibres provide valid candidates for inexpensive and replicable proton-neutron discrimination detectors