Conference Proceeding
Refine
Year of publication
- 2024 (14)
- 2023 (37)
- 2022 (49)
- 2021 (52)
- 2020 (55)
- 2019 (94)
- 2018 (78)
- 2017 (87)
- 2016 (81)
- 2015 (92)
- 2014 (67)
- 2013 (77)
- 2012 (89)
- 2011 (76)
- 2010 (75)
- 2009 (86)
- 2008 (61)
- 2007 (67)
- 2006 (94)
- 2005 (37)
- 2004 (37)
- 2003 (40)
- 2002 (34)
- 2001 (23)
- 2000 (19)
- 1999 (17)
- 1998 (23)
- 1997 (12)
- 1996 (7)
- 1995 (6)
- 1994 (4)
- 1993 (11)
- 1992 (6)
- 1991 (3)
- 1990 (2)
- 1989 (6)
- 1988 (3)
- 1987 (1)
- 1986 (2)
- 1985 (5)
- 1984 (3)
- 1983 (3)
- 1981 (2)
- 1980 (1)
- 1979 (1)
- 1978 (3)
- 1977 (2)
- 1975 (3)
- 1974 (1)
- 1973 (3)
Institute
- Fachbereich Elektrotechnik und Informationstechnik (302)
- Fachbereich Energietechnik (259)
- Fachbereich Medizintechnik und Technomathematik (243)
- Fachbereich Luft- und Raumfahrttechnik (209)
- Fachbereich Maschinenbau und Mechatronik (209)
- Solar-Institut Jülich (167)
- IfB - Institut für Bioengineering (152)
- Fachbereich Bauingenieurwesen (139)
- Fachbereich Wirtschaftswissenschaften (73)
- ECSM European Center for Sustainable Mobility (62)
Language
- English (1171)
- German (477)
- Italian (1)
- Multiple languages (1)
- Spanish (1)
Document Type
- Conference Proceeding (1651) (remove)
Keywords
- Biosensor (25)
- Blitzschutz (15)
- CAD (11)
- Finite-Elemente-Methode (11)
- civil engineering (11)
- Bauingenieurwesen (10)
- Lightning protection (9)
- Einspielen <Werkstoff> (6)
- Telekommunikationsmarkt (6)
- shakedown analysis (6)
Biomechanical simulation of different prosthetic meshes for repairing uterine/vaginal vault prolapse
(2017)
The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent.
Biomasse-Potential
(1985)
Recent earthquakes showed that low-rise URM buildings following codecompliant seismic design and details behaved in general very well without substantial damages. Although advances in simulation tools make nonlinear calculation methods more readily accessible to designers, linear analyses will still be the standard design method for years to come. The present paper aims to improve the linear seismic design method by providing a proper definition of the q-factor of URM buildings. Values of q-factors are derived for low-rise URM buildings with rigid diaphragms, with reference to modern structural configurations realized in low to moderate seismic areas of Italy and Germany. The behaviour factor components for deformation and energy dissipation capacity and for overstrength due to the redistribution of forces are derived by means of pushover analyses. As a result of the investigations, rationally based values of the behaviour factor q to be used in linear analyses in the range of 2.0 to 3.0 are proposed.
In: Alfha.net / Sektion Bauingenieurwesen: 1. [Erster] Erfahrungsaustausch : Absolventen des Fachbereichs Bauingenieurwesens berichten. 13. Oktober 2006. S. 19-20. Zusammenfassung des Vortrags: Prozessanalyse und Revision beim Umbau des Flughafens Hamburg, Beratung von Bauunternehmen, Sachverständigentätigkeit