Refine
Year of publication
- 2004 (161) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (75)
- INB - Institut für Nano- und Biotechnologien (32)
- IfB - Institut für Bioengineering (28)
- Fachbereich Energietechnik (25)
- Fachbereich Elektrotechnik und Informationstechnik (19)
- Fachbereich Luft- und Raumfahrttechnik (16)
- Fachbereich Chemie und Biotechnologie (8)
- Fachbereich Maschinenbau und Mechatronik (5)
- Freshman Institute (4)
- Solar-Institut Jülich (4)
Language
- English (161) (remove)
Document Type
- Article (131)
- Conference Proceeding (22)
- Book (7)
- Part of a Book (1)
Keywords
- Bauingenieurwesen (2)
- CAD (2)
- Elektromagnetischer Schutzschild (2)
- civil engineering (2)
- Audio-visual Art (1)
- Blitz (1)
- Blitzrisiko (1)
- Blitzschlag (1)
- Blitzschutz (1)
- Direct lightning strike (1)
Novel balanced inductor for compact differential systems / Sadeghfam, Arash; Heuermann, Holger
(2004)
For the application of the concept of Lightning Protection Zones (LPZ), the knowledge of the magnetic fields and induced voltages inside a structure is necessary. Laboratory experiments have been conducted at a downscaled model of a building (scale factor 1:6) to determine these electromagnetic quantities in case of a direct strike to the structure. The model (3 m x 2 m x 2 m) represented a small industrial building using the reinforcement of the concrete as electromagnetic shield. The magnetic fields and magnetic field derivatives were measured at several location inside the scaled model. Further, the voltages induced on three typical cable routes inside the model was determined. The influence of the lightning current waveshape, point-of-strike, bonding of the cable routes, and bridging of an expansion joint in the middle of the building on these quantities was studied.
In the paper the results obtained from experiments at a modelled reinforced building in case of a direct lightning strike are compared with calculations. The comparison includes peak values of the magnetic field Hmax, its derivative (dH/dt)max and of induced voltages umax in typical cable routings. The experiments are performed at a 1:6 scaled building and the results are extrapolated using the similarity relations theory. The calculations are based on the approximate formulae given in IEC 62305-4 and have to be supplemented by a rough estimation of the additional shielding effect of a second reinforcement layer. The comparison shows, that the measured peak values of the magnetic field and its derivative are mostly lower than the calculated. The induced voltages are in good agreement. Hence, calculations of the induced voltages based on IEC 62305-4 are a good method for lightning protection studies of buildings, where the reinforcement is used as a grid-like electromagnetic shield.