Refine
Year of publication
- 2014 (280) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (58)
- Fachbereich Chemie und Biotechnologie (43)
- Fachbereich Elektrotechnik und Informationstechnik (41)
- Fachbereich Wirtschaftswissenschaften (41)
- Fachbereich Energietechnik (40)
- INB - Institut für Nano- und Biotechnologien (35)
- IfB - Institut für Bioengineering (19)
- Fachbereich Maschinenbau und Mechatronik (15)
- Fachbereich Luft- und Raumfahrttechnik (13)
- Fachbereich Bauingenieurwesen (11)
Has Fulltext
- no (280) (remove)
Document Type
- Article (138)
- Conference Proceeding (55)
- Part of a Book (30)
- Book (21)
- Conference: Meeting Abstract (15)
- Report (8)
- Other (6)
- Patent (2)
- Conference Poster (1)
- Doctoral Thesis (1)
Keywords
New coupled finite-infinite element approach for wave propagation simulation of unbounded soil media
(2014)
Die PIA GmbH prüft seit fast 8 Jahren die Standsicherheit von Behältern für Kleinkläranlagen. Diese bestehen in der Regel aus Kunststoff oder Beton und müssen über ihre gesamte Lebensdauer den Beanspruchungen aus Handhabung, Einbau und Betrieb standhalten. Die Standsicherheit kann nach EN 12566 wahlweise durch einen rechnerischen Nachweis oder durch einen praktischen Nachweis wie die Bruchlastprüfung oder die Prüfung in der Grube erfolgen.
An enzyme system organized in a flow device was used to mimic a reversible Controlled NOT (CNOT) gate with two input and two output signals. Reversible conversion of NAD⁺ and NADH cofactors was used to perform a XOR logic operation, while biocatalytic hydrolysis of p-nitrophenyl phosphate resulted in an Identity operation working in parallel. The first biomolecular realization of a CNOT gate is promising for integration into complex biomolecular networks and future biosensor/biomedical applications.
In this study, a high-speed chemical imaging system was developed for visualization of the interior of a microfluidic channel. A microfluidic channel was constructed on the sensor surface of the light-addressable potentiometric sensor (LAPS), on which the ion concentrations could be measured in parallel at up to 64 points illuminated by optical fibers. The temporal change of pH distribution inside the microfluidic channel was recorded at a maximum rate of 100 frames per second (fps). The high frame rate allowed visualization of moving interfaces and plugs in the channel even at a flow velocity of 111 mm/s, which suggests the feasibility of plug-based microfluidic devices for flow-injection analysis (FIA).
In any books about genetics it can still today be read that our genetic code is called “degenerate” because it is still believed that 43 = 64 triplets encode the 20 essential amino acids. Indeed we have to assume the inverse law, what means that 34 = 81 exact code positions are really effective for our genetic code and encode the amino acids, compiled to proteins. This very important discovery leads to two completely new results that are limits-overlooking: 1) 34 (=81) genetic code positions mean exactly the same number as there are stable and naturally existing chemical elements in our universe. This famous argument should now lead to some alternative, as well as new fundamental conclusions about our existence. 2) A genetic code positioning system shows that nature is much smarter than expected: mutations are made less dangerous than believed, because they won't be that easily able any more to cause severe damages in the protein-synthesis. This should also lead to some alternative views upon evolution of life.