Article
Refine
Year of publication
- 2024 (55)
- 2023 (80)
- 2022 (93)
- 2021 (109)
- 2020 (135)
- 2019 (123)
- 2018 (127)
- 2017 (109)
- 2016 (118)
- 2015 (126)
- 2014 (142)
- 2013 (139)
- 2012 (130)
- 2011 (182)
- 2010 (140)
- 2009 (199)
- 2008 (180)
- 2007 (176)
- 2006 (179)
- 2005 (188)
- 2004 (214)
- 2003 (154)
- 2002 (167)
- 2001 (157)
- 2000 (173)
- 1999 (153)
- 1998 (165)
- 1997 (154)
- 1996 (140)
- 1995 (147)
- 1994 (136)
- 1993 (108)
- 1992 (102)
- 1991 (74)
- 1990 (82)
- 1989 (79)
- 1988 (80)
- 1987 (77)
- 1986 (65)
- 1985 (59)
- 1984 (56)
- 1983 (47)
- 1982 (38)
- 1981 (39)
- 1980 (50)
- 1979 (43)
- 1978 (41)
- 1977 (22)
- 1976 (25)
- 1975 (18)
- 1974 (13)
- 1973 (6)
- 1972 (15)
- 1971 (7)
- 1970 (2)
- 1968 (2)
- 1967 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1585)
- Fachbereich Wirtschaftswissenschaften (704)
- Fachbereich Elektrotechnik und Informationstechnik (631)
- Fachbereich Chemie und Biotechnologie (605)
- Fachbereich Energietechnik (605)
- INB - Institut für Nano- und Biotechnologien (538)
- Fachbereich Maschinenbau und Mechatronik (497)
- IfB - Institut für Bioengineering (444)
- Fachbereich Luft- und Raumfahrttechnik (376)
- Fachbereich Bauingenieurwesen (334)
Language
Document Type
- Article (5641) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- Rapid Prototyping (4)
- SLM (4)
Steuerreformgesetz 1990
(1989)
Steuerreformgesetz 1990
(1989)
Effektivzins und APR
(1991)
Background
Hip fractures are a common and costly health problem, resulting in significant morbidity and mortality, as well as high costs for healthcare systems, especially for the elderly. Implementing surgical preventive strategies has the potential to improve the quality of life and reduce the burden on healthcare resources, particularly in the long term. However, there are currently limited guidelines for standardizing hip fracture prophylaxis practices.
Methods
This study used a cost-effectiveness analysis with a finite-state Markov model and cohort simulation to evaluate the primary and secondary surgical prevention of hip fractures in the elderly. Patients aged 60 to 90 years were simulated in two different models (A and B) to assess prevention at different levels. Model A assumed prophylaxis was performed during the fracture operation on the contralateral side, while Model B included individuals with high fracture risk factors. Costs were obtained from the Centers for Medicare & Medicaid Services, and transition probabilities and health state utilities were derived from available literature. The baseline assumption was a 10% reduction in fracture risk after prophylaxis. A sensitivity analysis was also conducted to assess the reliability and variability of the results.
Results
With a 10% fracture risk reduction, model A costs between $8,850 and $46,940 per quality-adjusted life-year ($/QALY). Additionally, it proved most cost-effective in the age range between 61 and 81 years. The sensitivity analysis established that a reduction of ≥ 2.8% is needed for prophylaxis to be definitely cost-effective. The cost-effectiveness at the secondary prevention level was most sensitive to the cost of the contralateral side’s prophylaxis, the patient’s age, and fracture treatment cost. For high-risk patients with no fracture history, the cost-effectiveness of a preventive strategy depends on their risk profile. In the baseline analysis, the incremental cost-effectiveness ratio at the primary prevention level varied between $11,000/QALY and $74,000/QALY, which is below the defined willingness to pay threshold.
Conclusion
Due to the high cost of hip fracture treatment and its increased morbidity, surgical prophylaxis strategies have demonstrated that they can significantly relieve the healthcare system. Various key assumptions facilitated the modeling, allowing for adequate room for uncertainty. Further research is needed to evaluate health-state-associated risks.
Persistent infection with the high-risk Human Papillomavirus type 16 (HPV 16) is the causative event for the development of cervical cancer and other malignant tumors of the anogenital tract and of the head and neck. Despite many attempts to develop therapeutic vaccines no candidate has entered late clinical trials. An interesting approach is a DNA based vaccine encompassing the nucleotide sequence of the E6 and E7 viral oncoproteins. Because both proteins are consistently expressed in HPV infected cells they represent excellent targets for immune therapy. Here we report the development of 8 DNA vaccine candidates consisting of differently rearranged HPV-16 E6 and E7 sequences within one molecule providing all naturally occurring epitopes but supposedly lacking transforming activity. The HPV sequences were fused to the J-domain and the SV40 enhancer in order to increase immune responses. We demonstrate that one out of the 8 vaccine candidates induces very strong cellular E6- and E7- specific cellular immune responses in mice and, as shown in regression experiments, efficiently controls growth of HPV 16 positive syngeneic tumors. This data demonstrates the potential of this vaccine candidate to control persistent HPV 16 infection that may lead to malignant disease. It also suggests that different sequence rearrangements influence the immunogenecity by an as yet unknown mechanism.
Detecting synchronization clusters in multivariate time series via coarse-graining of Markov chains
(2007)
In this work, we present a compact, bifunctional chip-based sensor setup that measures the temperature and electrical conductivity of water samples, including specimens from rivers and channels, aquaculture, and the Atlantic Ocean. For conductivity measurements, we utilize the impedance amplitude recorded via interdigitated electrode structures at a single triggering frequency. The results are well in line with data obtained using a calibrated reference instrument. The new setup holds for conductivity values spanning almost two orders of magnitude (river versus ocean water) without the need for equivalent circuit modelling. Temperature measurements were performed in four-point geometry with an on-chip platinum RTD (resistance temperature detector) in the temperature range between 2 °C and 40 °C, showing no hysteresis effects between warming and cooling cycles. Although the meander was not shielded against the liquid, the temperature calibration provided equivalent results to low conductive Milli-Q and highly conductive ocean water. The sensor is therefore suitable for inline and online monitoring purposes in recirculating aquaculture systems.