Refine
Year of publication
- 2012 (164) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (59)
- INB - Institut für Nano- und Biotechnologien (28)
- IfB - Institut für Bioengineering (28)
- Fachbereich Elektrotechnik und Informationstechnik (25)
- Fachbereich Chemie und Biotechnologie (15)
- Fachbereich Maschinenbau und Mechatronik (14)
- Solar-Institut Jülich (13)
- Fachbereich Luft- und Raumfahrttechnik (10)
- Fachbereich Wirtschaftswissenschaften (10)
- Fachbereich Bauingenieurwesen (9)
Language
- English (164) (remove)
Document Type
- Article (82)
- Conference Proceeding (59)
- Book (6)
- Part of a Book (5)
- Conference: Meeting Abstract (5)
- Doctoral Thesis (5)
- Other (1)
- Review (1)
Keywords
- (Bio)degradation (1)
- 802.15.4 (1)
- Acceleration (1)
- Afterload (1)
- Alginate beads (1)
- Anastomotic leakage (1)
- Autolysis (1)
- Avalanche (1)
- Bank-issued Warrants (1)
- Bio-Sensors (1)
With a steady increase of regulatory requirements for business processes, automation support of compliance management is a field garnering increasing attention in Information Systems research. Several approaches have been developed to support compliance checking of process models. One major challenge for such approaches is their ability to handle different modeling techniques and compliance rules in order to enable widespread adoption and application. Applying a structured literature search strategy, we reflect and discuss compliance-checking approaches in order to provide an insight into their generalizability and evaluation. The results imply that current approaches mainly focus on special modeling techniques and/or a restricted set of types of compliance rules. Most approaches abstain from real-world evaluation which raises the question of their practical applicability. Referring to the search results, we propose a roadmap for further research in model-based business process compliance checking.
N,N-Dialkylamino(thiocarbonyl)-N′-picolylbenzamidines react with (NEt4)2[M(CO)3X3] (M = Re, X = Br; M = Tc, X = Cl) under formation of neutral [M(CO)3L] complexes in high yields. The monoanionic NNS ligands bind in a facial coordination mode and can readily be modified at the (CS)NR1R2 moiety. The complexes [99Tc(CO)3(LPyMor)] and [Re(CO)3(L)] (L = LPyMor, LPyEt) were characterized by X-ray diffraction. Reactions of [99mTc(CO)3(H2O)3]+ with the N′-thiocarbamoylpicolylbenzamidines give the corresponding 99mTc complexes. The ester group in HLPyCOOEt allows linkage between biomolecules and the metal core.
Air- and water-stable phenyl complexes with nitridotechnetium(V) cores can be prepared by straightforward procedures. [TcNPh2(PPh3)2] is formed by the reaction of [TcNCl2(PPh3)2] with PhLi. The analogous N-heterocyclic carbene (NHC) compound [TcNPh2(HLPh)2], where HLPh is 1,3,4-triphenyl-1,2,4-triazol-5-ylidene, is available from (NBu4)[TcNCl4] and HLPh or its methoxo-protected form. The latter compound allows the comparison of different Tc–C bonds within one compound. Surprisingly, the Tc chemistry with such NHCs does not resemble that of corresponding Re complexes, where CH activation and orthometalation dominate.
Assessment of RF Safety of Transmit Coils at 7 Tesla by Experimental and Numerical Procedures (490.)
(2012)
This contribution discusses the utilization of RF power in an MRI system with RF mode shimming which enables the superposition of circularly polarized modes of a transmit RF coil array driven by a Butler matrix. Since the required power for the individual modes can vary widely, mode-shimming can result in a significant underutilization of the total available RF power. A variable power combiner (VPC) is proposed to improve the power utilization: it can be realized as a reconfiguration of the MRI transmit system by the inclusion of one additional matrix network which receives the power from all transmit amplifiers at its input ports and provides any desired (combined) power distribution at its output ports by controlling the phase and amplitude of the amplifiers’ input signals. The power distribution at the output ports of the VPC is then fed into the “mode” ports of the coil array Butler matrix in order to superimpose the spatial modes at the highest achievable power utilization. The VPC configuration is compared to the standard configuration of the transmit chain of our MRI system with 8 transmit channels and 16 coils. In realistic scenarios, improved power utilization was achieved from 17% to 60% and from 14% to 55% for an elliptical phantom and a region of interest in the abdomen, respectively, and an increase of the power utilization of 1 dB for a region of interest in the upper leg. In general, it is found that the VPC allows significant improvement in power utilization when the shimming solution demands only a few modes to be energized, while the technique can yield loss in power utilization in cases with many modes required at high power level.
31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and Burn:x-wiley:07403194:media:MRM24175:tex2gif-stack-1 measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer.
s the magnetic field strength and therefore the operational frequency in MRI are increased, the radiofrequency wavelength approaches the size of the human head/body, resulting in wave effects which cause signal decreases and dropouts. Especially, whole-body imaging at 7 T and higher is therefore challenging. Recently, an acquisition scheme called time-interleaved acquisition of modes has been proposed to tackle the inhomogeneity problems in high-field MRI. The basic premise is to excite two (or more) different Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-1 modes using static radiofrequency shimming in an interleaved acquisition, where the complementary radiofrequency patterns of the two modes can be exploited to improve overall signal homogeneity. In this work, the impact of time-interleaved acquisition of mode on image contrast as well as on time-averaged specific absorption rate is addressed in detail. Time-interleaved acquisition of mode is superior in Burn:x-wiley:07403194:media:MRM23081:tex2gif-stack-2 homogeneity compared with conventional radiofrequency shimming while being highly specific absorption rate efficient. Time-interleaved acquisition of modes can enable almost homogeneous high-field imaging throughout the entire field of view in PD, T2, and T2*-weighted imaging and, if a specified homogeneity criterion is met, in T1-weighted imaging as well.
We present an effective finite difference formulation for implementing and modeling multiple borehole heat exchangers (BHE) in the general 3-D coupled heat and flow transport code SHEMAT. The BHE with arbitrary length can be either coaxial or double U-shaped. It is particularly suitable for modeling deep BHEs which contain varying pipe diameters and materials.
Usually, in numerical simulations, a fine discretization of the BHE assemblage is required, due to the large geometric aspect ratios involved. This yields large models and long simulation times. The approach avoids this problem by considering heat transport between fluid and the soil through pipes and grout via thermal resistances. Therefore, the simulation time can be significantly reduced.
The coupling with SHEMAT is realized by introducing an effective heat generation. Due to this connection, it is possible to consider heterogeneous geological models, as well as the influence of groundwater flow. This is particularly interesting when studying the long term behavior of a single BHE or a BHE field. Heating and cooling loads can enter the model with an arbitrary interval, e.g. from hourly to monthly values. When dealing with large BHE fields, computing times can be further significantly reduced by focusing on the temperature field around the BHEs, without explicitly modeling inlet and outlet temperatures. This allows to determine the possible migration of cold and warm plumes due to groundwater flow, which is of particular importance in urban areas with a high BHE installation density.
The model is validated against the existing BHE modeling codes EWS and EED. A comparison with monitoring data from a deep BHE in Switzerland shows a good agreement. Synthetic examples demonstrate the field of application of this model.
Chelate stabilization of a titanium(IV)–salan alkoxide by ligand exchange with 2,6-pyridinedicarboxylic acid (dipic) resulted in heptacoordinate complex 3 which is not redox-active, stable on silica gel and has increased aqueous stability. 3 is highly toxic in HeLa S3 and Hep G2 and has enhanced antitumor efficacy in a mouse cervical-cancer model.
Persistent infection with high-risk human papillomaviruses (hrHPV) can result in the formation of anogenital cancers. As hrHPV proteins E6 and E7 are required for cancer initiation and maintenance, they are ideal targets for immunotherapeutic interventions. Previously, we have described the development of DNA vaccines for the induction of HPV16 E6 and E7 specific T cell immunity. These vaccines consist of ‘gene-shuffled’ (SH) versions of HPV16 E6 and E7 that were fused to Tetanus Toxin Fragment C domain 1 (TTFC) and were named TTFC-E6SH and TTFC-E7SH. Gene-shuffling was performed to avoid the risk of inducing malignant transformation at the vaccination site. Here, we describe the preclinical safety evaluation of these candidate vaccines by analysis of their transforming capacity in vitro using established murine fibroblasts (NIH 3T3 cells) and primary human foreskin keratinocytes (HFKs). We demonstrate that neither ectopic expression of TTFC-E6SH and TTFC-E7SH alone or in combination enabled NIH 3T3 cells to form colonies in soft agar. In contrast, expression of HPV16 E6WT and E7WT alone or in combination resulted in effective transformation. Similarly, retroviral transduction of HFKs from three independent donors with both TTFC-E6SH and TTFC-E7SH alone or in combination did not show any signs of immortalization. In contrast, the combined expression of E6WT and E7WT induced immortalization in HFKs from all donors. Based on these results we consider it justified to proceed to clinical evaluation of DNA vaccines encoding TTFC-E6SH and TTFC-E7SH in patients with HPV16 associated (pre)malignancies.
The radio-based wireless data communication has made the realization of new technical solutions possible in many fields of the automation technology (AT). For about ten years, a constant disproportionate growth of wireless technologies can be observed in the automation technology.
However, it shows that especially for the AT, conventional technologies of office automation are unsuitable and/or not manageable. The employment of mobile services in the industrial automation technology has the potential of significant cost and time savings. This leads to an increased productivity in various fields of the AT, for example in the factory and process automation or in production logistics. In this paper technologies and solutions for an automation-suited supply of mobile wireless services will be introduced under the criteria of real time suitability, IT-security and service orientation.
Emphasis will be put on the investigation and development of wireless convergence layers for different radio technologies, on the central provision of support services for an easy-to-use, central, backup enabled management of combined wired / wireless networks and on the study on integrability in a Profinet real-time Ethernet network.