Refine
Year of publication
Institute
- Fachbereich Chemie und Biotechnologie (537) (remove)
Has Fulltext
- no (537) (remove)
Language
- English (537) (remove)
Document Type
- Article (458)
- Conference Proceeding (24)
- Part of a Book (18)
- Patent (17)
- Book (9)
- Conference: Meeting Abstract (8)
- Conference Poster (1)
- Preprint (1)
- Review (1)
Keywords
- Heparin (3)
- Chemometrics (2)
- IR spectroscopy (2)
- NMR spectroscopy (2)
- Principal component analysis (2)
- Standardization (2)
- (R)- or (S)- gamma-valerolactone (1)
- 4-hydroxy valeric acid (1)
- ABE (1)
- Acid crash (1)
- Alginate beads (1)
- Analytics (1)
- Authenticity (1)
- Bioeconomy (1)
- Bioethanol (1)
- Biomass (1)
- Biorefinery (1)
- Biorefinery definitions (1)
- Bladder (1)
- Bragg peak (1)
- Butanol (1)
- C. acetobutylicum (1)
- CRISPR/Cas9 (1)
- Chimeric liver-humanized mice (1)
- Chiralidon-R (1)
- Chiralidon-S (1)
- Crude heparin (1)
- Cyclotron production (1)
- Decentral (1)
- Dehydrogenase (1)
- Detergent protease (1)
- Deuterated solvents (1)
- Deuterium NMR (1)
- Diaphorase (1)
- Drug distribution (1)
- Drug metabolism (1)
- Enzymatic biosensor (1)
- Extracellular enzymes (1)
- Ga-68 (1)
- Growth modelling (1)
- Hypersecretion (1)
- IR (1)
- Inorganic ions (1)
- Introduction (1)
- Ions (1)
- Knockout mice (1)
- Levulinic acid (1)
- Lignocellulose feedstook (1)
- Linear discriminant analysis (1)
- Manufacturer (1)
- Marker-free mutagenesis (1)
- Mechanical (1)
- Mechanical simulation (1)
- Medical radionuclide production (1)
- Metabolic shift (1)
- Metal contaminants (1)
- Microfluidic solvent extraction (1)
- Minor chemistry (1)
- Molecular modelling (1)
- Molecular weight determination (1)
- NMR (1)
- On-site (1)
- P2G (1)
- PLS-regression (1)
- Physical chemistry (1)
- Physical chemistry basics (1)
- Physical chemistry starters (1)
- Pre-culture (1)
- Pre-treatment (1)
- Process schemes (1)
- Quality control (1)
- Quantum chemistry (1)
- Reconstruction (1)
- Renewable resources (1)
- Simultaneous determination (1)
- Soft independent modeling of class analogy (1)
- Stenotrophomonas maltophilia (1)
- Thermodynamics as minor (1)
- Toxicology (1)
- USP (1)
- Uracil-phosphoribosyltransferase (1)
- Ureter (1)
- actuator-sensor system (1)
- aspergillus (1)
- bacterial cellulose (1)
- bi-enzyme biosensor (1)
- bioavailability (1)
- biodegradable polymers (1)
- biological dosimeter (1)
- biomethane (1)
- borehole disposal (1)
- bubble column (1)
- capacitive field-effect sensor (1)
- coculture (1)
- deficit irrigation (1)
- disposal facility (1)
- drug metabolising enzymes (1)
- drug–drug interactions (1)
- elastomers (1)
- enzyme kinetics (1)
- enzyme-logic gate (1)
- exopolysaccharides (1)
- filamentous fungi (1)
- genome engineering (1)
- geological disposal (1)
- glycine (1)
- human metabolites (1)
- hydrogel (1)
- hydrogels (1)
- light-addressable electrode (1)
- light-addressable potentiometric sensor (1)
- mechanical properties (1)
- methanation (1)
- microfluidics (1)
- micronutrients (1)
- neutrons (1)
- nuclear waste (1)
- onion (1)
- optical fibers (1)
- penicillinase (1)
- plug flow reactor (1)
- polyaspartic acid (1)
- prebiotic (1)
- proton therapy (1)
- protons (1)
- pullulan (1)
- qNMR (1)
- relative dosimetry (1)
- retention time (1)
- rubber (1)
- superabsorbent polymers (1)
- supramolecular structures (1)
- swelling properties (1)
- theory and modeling (1)
- tobacco mosaic virus (TMV) (1)
- transporters (1)
- urease (1)
- water economy (1)
- yield (1)
An amperometric biosensor using a substrate recycling principle was realized for the detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and Ringer’s solution at pH 6.5 and pH 7.4, respectively. In proof-of-concept experiments, a Boolean logic-gate principle has been applied to develop a digital adrenaline biosensor based on an enzyme AND logic gate. The obtained results demonstrate that the developed digital biosensor is capable for a rapid qualitative determination of the presence/absence of adrenaline in a YES/NO statement. Such digital biosensor could be used in clinical diagnostics for the control of a correct insertion of a catheter in the adrenal veins during adrenal venous-sampling procedure.
A capacitive electrolyte-insulator-semiconductor (EIS) field-effect biosensor for acetoin detection has been presented for the first time. The EIS sensor consists of a layer structure of Al/p-Si/SiO₂/Ta₂O₅/enzyme acetoin reductase. The enzyme, also referred to as butane-2,3-diol dehydrogenase from B. clausii DSM 8716T, has been recently characterized. The enzyme catalyzes the (R)-specific reduction of racemic acetoin to (R,R)- and meso-butane-2,3-diol, respectively. Two different enzyme immobilization strategies (cross-linking by using glutaraldehyde and adsorption) have been studied. Typical biosensor parameters such as optimal pH working range, sensitivity, hysteresis, linear concentration range and long-term stability have been examined by means of constant-capacitance (ConCap) mode measurements. Furthermore, preliminary experiments have been successfully carried out for the detection of acetoin in diluted white wine samples.
An amperometric enzyme biosensor has been applied for the detection of adrenaline. The adrenaline biosensor has been prepared by modification of an oxygen electrode with the enzyme laccase that operates at a broad pH range between pH 3.5 to pH 8. The enzyme molecules were immobilized via cross-linking with glutaraldehyde. The sensitivity of the developed adrenaline biosensor in different pH buffer solutions has been studied.