Conference Proceeding
Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (210) (remove)
Language
- English (210) (remove)
Document Type
- Conference Proceeding (210) (remove)
Keywords
- Biosensor (25)
- CAD (7)
- Finite-Elemente-Methode (7)
- civil engineering (7)
- Bauingenieurwesen (6)
- Clusterion (4)
- Limit analysis (4)
- Natural language processing (4)
- Air purification (3)
- Einspielen <Werkstoff> (3)
- Hämoglobin (3)
- Luftreiniger (3)
- Plasmacluster ion technology (3)
- Raumluft (3)
- Shakedown analysis (3)
- Sonde (3)
- shakedown analysis (3)
- Bruchmechanik (2)
- Clustering (2)
- Eisschicht (2)
- Erythrozyt (2)
- FEM (2)
- Information extraction (2)
- Kohlenstofffaser (2)
- Lipopolysaccharide (2)
- Shakedown (2)
- Stickstoffmonoxid (2)
- biosensor (2)
- celldrum technology (2)
- limit analysis (2)
- lipopolysaccharides (2)
- nitric oxide gas (2)
- 3-nitrofluoranthene (1)
- Active learning (1)
- Adsorption (1)
- Agent-based simulation (1)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomose (1)
- Anastomosis (1)
- Autofluoreszenzverfahren (1)
- BTEX compounds (1)
- Bakterien (1)
- Bio-Sensors (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Biophoton (1)
- Biosensorik (1)
- Blitzschutz (1)
- CAD ; (1)
- CO (1)
- Chance constrained programming (1)
- Cloud Computing (1)
- Cloud Service Broker (1)
- Conducing polymer (1)
- Dattel (1)
- Deep learning (1)
- Dekontamination (1)
- ECT (1)
- EEG (1)
- EPN (1)
- Einspiel-Analyse (1)
- Einspielanalyse (1)
- Elastodynamik (1)
- Elektrodynamik (1)
- Endothelzelle (1)
- Energy market design (1)
- Evolution of damage (1)
- Exact Ilyushin yield surface (1)
- Extension fracture (1)
- Extension strain criterion (1)
- Festkörper (1)
- Fibroblast (1)
- Finite element method (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fluorescence (1)
- Force (1)
- GaAs hot electron injector (1)
- Gas sensor (1)
- Grid Computing (1)
- Gunn diode (1)
- Heavy metal detection (1)
- High throughput experimentation (1)
- Hotplate (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hydrogen sensor (1)
- I3S 2005 (1)
- ISFET (1)
- Impedance Spectroscopy (1)
- Information Extraction (1)
- International Symposium on Sensor Science (1)
- Iterative learning control (1)
- Knee (1)
- Körpertemperatur (1)
- LED chip (1)
- Level sensor (1)
- Lichtstreuungsbasierte Instrumente (1)
- Load modeling (1)
- MEMS (1)
- Machine learning (1)
- Main sensitivity (1)
- Market modeling (1)
- Mechanische Beanspruchung (1)
- Microreactors (1)
- Mohr–Coulomb criterion (1)
- Multi-dimensional wave propagation (1)
- Nano Materials (1)
- Nanomaterial (1)
- Nanoparticles (1)
- Nanopartikel (1)
- Nanostructuring (1)
- Nanotechnologie (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Natriumhypochlorit (1)
- Natural Language Processing (1)
- Natural language understanding (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Organophosphorus (1)
- Ostazine Orange (1)
- PFM (1)
- Pflanzenphysiologie (1)
- Pflanzenscanner (1)
- Phenylalanine determination (1)
- Potentiometry (1)
- Process model (1)
- Profile Extraction (1)
- Profile extraction (1)
- Proteine (1)
- Pseudomonas putida (1)
- Quartz crystal nanobalance (QCN) (1)
- Quartz micro balances (1)
- Query learning (1)
- Random variable (1)
- Ratcheting (1)
- Reaction-diffusion (1)
- Relation classification (1)
- Reliability of structures (1)
- Reproducible research (1)
- Sensitivity (1)
- Sepsis (1)
- Sleep EEG (1)
- Solid amalgam electrodes (1)
- Stochastic programming (1)
- Supraleiter (1)
- Technische Mechanik (1)
- Text Mining (1)
- Text mining (1)
- Tin oxide (1)
- Tobacco mosaic virus (1)
- Traglast (1)
- Traglastanalyse (1)
- Training (1)
- Trustworthy artificial intelligence (1)
- UML (1)
- Unified Modeling Language (1)
- Wafer (1)
- Wasserbrücke (1)
- Wasserstoffperoxid (1)
- Wellen (1)
- Workflow (1)
- Workflow Orchestration (1)
- acetoin (1)
- activated nanostructured carbon (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- ammonia gas sensors (1)
- amperometric sensor (1)
- antimony doped tin oxide (1)
- autofluorescence-based detection system (1)
- biopotential electrodes (1)
- capacitive field-effect biosensor (1)
- capillary micro-droplet cell (1)
- carcinogens (1)
- catalytic decomposition (1)
- chemical reduction method (1)
- contractile tension (1)
- cross sensitivity (1)
- cytosolic water diffusion (1)
- date palm tree (1)
- design-by-analysis (1)
- doped metal oxide (1)
- doped silicon (1)
- doping (1)
- electrical capacitance tomography (1)
- electro-migration (1)
- electronic noses dendronized polymers inverted mesa technology (1)
- enzymatic methods (1)
- enzyme immobilisation (1)
- enzyme immobilization (1)
- fenitrothion (1)
- finite element analysis (1)
- fluidic (1)
- gas sensor (1)
- gas sensor array (1)
- heater metallisation (1)
- hemoglobin (1)
- hemoglobin dynamics (1)
- high-temperature stability (1)
- humidity (1)
- hydrogel (1)
- hydrogen peroxide (1)
- image sensor (1)
- imaging (1)
- impedance spectroscopy (1)
- ion-selective electrodes (1)
- kontraktile Spannung (1)
- lab-on-a-chip (1)
- lab-on-chip (1)
- layer expansion (1)
- lenslet array (1)
- light scattering analysis (1)
- lightning flash (1)
- limit and shakedown analysis (1)
- limit load (1)
- linear kinematic hardening (1)
- lower bound theorem (1)
- magnetic particles (1)
- material shakedown (1)
- matrix method (1)
- mechanical waves (1)
- metal oxide (1)
- microreactor (1)
- microwave generation (1)
- modeling biosensor (1)
- modelling (1)
- modified electrode (1)
- multi-interface measurement (1)
- nanostructured carbonized plant parts (1)
- nanostrukturierte carbonisierte Pflanzenteile (1)
- nitrogen oxides (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- organic PVC membranes (1)
- pH-based biosensing (1)
- pattern-size reduction (1)
- plant scanner (1)
- plasma generated ions (1)
- polymer composites (1)
- porous Pt electrode (1)
- principal component (1)
- probabilistic fracture mechanics (1)
- protein (1)
- quantum charging (1)
- ratchetting (1)
- reliability (1)
- rhAPC (1)
- screen-printing (1)
- second-order reliability method (1)
- self-aligned patterning (1)
- sensing properties (1)
- sensors (1)
- shakedown (1)
- sterilisation (1)
- subsurface ice research (1)
- subsurface probe (1)
- surface modification (1)
- swift heavy ions (1)
- thick-film technology (1)
- thin-film microsensors (1)
- voltammetry (1)
- wafer-level testing (1)
- water bridge phenomenon (1)
The human arm consists of the humerus (upper arm), the medial ulna and the lateral radius (forearm). The joint between the humerus and the ulna is called humeroulnar joint and the joint between the humerus and the radius is called humeroradial joint. Lateral and medial collateral ligaments stabilize the elbow. Statistically, 2.5 out of 10,000 people suffer from radial head fractures [1]. In these fractures the cartilage is often affected. Caused by the injured cartilage, degenerative diseases like posttraumatic arthrosis may occur. The resulting pain and reduced range of motion have an impact on the patient’s quality of life. Until now, there has not been a treatment which allows typical loads in daily life activities and offers good long-term results. A new surgical approach was developed with the motivation to reduce the progress of the posttraumatic arthrosis. Here, the radius is shortened by 3 mm in the proximal part [2]. By this means, the load of the radius is intended to be reduced due to a load shift to the ulna. Since the radius is the most important stabilizer of the elbow it has to be confirmed that the stability is not affected. In the first test (Fig. 1 left), pressure distributions within the humeroulnar and humeroradial joints a native and a shortened radius were measured using resistive pressure sensors (I5076 and I5027, Tekscan, USA). The humerus was loaded axially in a tension testing machine (Z010, Zwick Roell, Germany) in 50 N steps up to 400 N. From the humerus the load is transmitted through both the radius and the ulna into the hand which is fixed on the ground. In the second test (Fig. 1 right), the joint stability was investigated using a digital image correlation system to measure the displacement of the ulna. Here, the humerus is fixed with a desired flexion angle and the unconstrained forearm lies on the ground. A rope connects the load actuator with a hook fixed in the ulna. A guide roller is used so that the rope pulls the ulna horizontally when a tensile load is applied. This creates a moment about the elbow joint with a maximum value of 7.5 Nm. Measurements were performed with varying flexion angles (0°, 30°, 60°, 90°, 120°). For both tests and each measurement, seven specimens were used. Student ́s t-test was employed to determine whether the mean values of the measurements in native specimen and operated specimens differ significantly.
In: Net-distributed Co-operation : Xth International Conference on Computing in Civil and Building Engineering, Weimar, June 02 - 04, 2004 ; proceedings / [ed. by Karl Beuke ...] . - Weimar: Bauhaus-Univ. Weimar 2004. - 1. Aufl. . Seite 1-14 ISBN 3-86068-213-X International Conference on Computing in Civil and Building Engineering <10, 2004, Weimar> Summary In our project, we develop new tools for the conceptual design phase. During conceptual design, the coarse functionality and organization of a building is more important than a detailed worked out construction. We identify two roles, first the knowledge engineer who is responsible for knowledge definition and maintenance; second the architect who elaborates the conceptual de-sign. The tool for the knowledge engineer is based on graph technology, it is specified using PROGRES and the UPGRADE framework. The tools for the architect are integrated to the in-dustrial CAD tool ArchiCAD. Consistency between knowledge and conceptual design is en-sured by the constraint checker, another extension to ArchiCAD.
Effective training requires high muscle forces potentially leading to training-induced injuries. Thus, continuous monitoring and controlling of the loadings applied to the musculoskeletal system along the motion trajectory is required. In this paper, a norm-optimal iterative learning control algorithm for the robot-assisted training is developed. The algorithm aims at minimizing the external knee joint moment, which is commonly used to quantify the loading of the medial compartment. To estimate the external knee joint moment, a musculoskeletal lower extremity model is implemented in OpenSim and coupled with a model of an industrial robot and a force plate mounted at its end-effector. The algorithm is tested in simulation for patients with varus, normal and valgus alignment of the knee. The results show that the algorithm is able to minimize the external knee joint moment in all three cases and converges after less than seven iterations.
Label-free Electrostatic Detection of DNA Amplification by PCR Using Capacitive Field-effect Devices
(2016)
A capacitive field-effect EIS (electrolyte-insulator-semiconductor) sensor modified with a positively charged weak polyelectrolyte of poly(allylamine hydrochloride) (PAH)/single-stranded probe DNA (ssDNA) bilayer has been used for a label-free electrostatic detection of pathogen-specific DNA amplification via polymerase chain reaction (PCR). The sensor is able to distinguish between positive and negative PCR solutions, to detect the existence of target DNA amplicons in PCR samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process.
Label-free sensing of biomolecules by their intrinsic molecular charge using field-effect devices
(2015)
Light-stimulated hydrogel actuators with incorporated graphene oxide for microfluidic applications
(2015)
Limit and shakedown theorems are exact theories of classical plasticity for the direct computation of safety factors or of the load carrying capacity under constant and varying loads. Simple versions of limit and shakedown analysis are the basis of all design codes for pressure vessels and pipings. Using Finite Element Methods more realistic modeling can be used for a more rational design. The methods can be extended to yield optimum plastic design. In this paper we present a first implementation in FE of limit and shakedown analyses for perfectly plastic material. Limit and shakedown analyses are done of a pipe–junction and a interaction diagram is calculated. The results are in good correspondence with the analytic solution we give in the appendix.
Direct methods comprising limit and shakedown analysis is a branch of computational mechanics. It plays a significant role in mechanical and civil engineering design. The concept of direct method aims to determinate the ultimate load bearing capacity of structures beyond the elastic range. For practical problems, the direct methods lead to nonlinear convex optimization problems with a large number of variables and onstraints. If strength and loading are random quantities, the problem of shakedown analysis is considered as stochastic programming. This paper presents a method so called chance constrained programming, an effective method of stochastic programming, to solve shakedown analysis problem under random condition of strength. In this our investigation, the loading is deterministic, the strength is distributed as normal or lognormal variables.
7th International Conference on Reliability of Materials and Structures (RELMAS 2008). June 17 - 20, 2008 ; Saint Petersburg, Russia. pp 354-358. Reprint with corrections in red Introduction Analysis of advanced structures working under extreme heavy loading such as nuclear power plants and piping system should take into account the randomness of loading, geometrical and material parameters. The existing reliability are restricted mostly to the elastic working regime, e.g. allowable local stresses. Development of the limit and shakedown reliability-based analysis and design methods, exploiting potential of the shakedown working regime, is highly needed. In this paper the application of a new algorithm of probabilistic limit and shakedown analysis for shell structures is presented, in which the loading and strength of the material as well as the thickness of the shell are considered as random variables. The reliability analysis problems may be efficiently solved by using a system combining the available FE codes, a deterministic limit and shakedown analysis, and the First and Second Order Reliability Methods (FORM/SORM). Non-linear sensitivity analyses are obtained directly from the solution of the deterministic problem without extra computational costs.